WKC05/02 PG. 3

F

Note: 

 Glass doors and/or windows are not included in our calculations and should not be used in a wine

enclosure.

CONVERTED CLOSETS APPLICATIONS

  The 

BREEZAIRE WKC

 series cooling units were designed and engineered for cabinets and credenzas.  However if you

have looked at the

 BREEZAIRE WK

 series cooling unit and you feel the

 WKC

 series units will better serve your

application you must follow theses specifications:

F

  This is a mechanical piece of equipment, it will make noise and produce heat on the warm side exterior grille
(Fig. 3).  Remember, unit installation location is not only important inside the wine cellar, but just as important is
where the warm side exhaust air is being rejected.

SIZING GUIDE & SPECIFICATIONS

This guide to be used only for enclosures meeting the above construction requirements.

BREEZAIRE Model

Electrical

Dimensions (inches)

Weight (Lbs.)

WKC(E) 1060

3 Amp

18W x 10.5H x 16.5D

45

WKC(E) 2200

4 Amp

18W x 10.5H x 16.5D

55

Note: All units are 115 Volt, 60 Hz

INSTALLATION

  Before installing the unit, inspect it again for any shipping damage.  Test the unit by placing it in a room where the
temperature is above 65°F.  Position the unit to allow cold air to flow from evaporator outlet. (See Fig. 1) Plug the unit's
electrical cord into a properly grounded electrical outlet of adequate capacity (see unit specification for unit electrical
requirements).

  The thermostat has no "off" position; therefore it will begin to run within 5 minutes of being plugged in.  Allow it to run for
a minimum of 15 minutes.  There should be a flow of cool air from the lower evaporator outlet side (see Fig. 1) and warm
air should be flowing from the rear opening on the exterior grille side (see Fig. 3).  If there is no airflow or no change in
temperature on either side, contact your dealer.

F

 

  BREEZAIRE

 units should 

NOT

 be installed in a fire rated wall without consulting your local building inspector

and building codes.

F

 

  If your installation cannot be performed in accordance with these instructions contact your dealer.

F

 

  The unit must be installed in the upright position and is not designed to have duct work on either the warm air or
cold air sides.  Do not drill any holes into the cooling unit.  It may damage the unit, promotes rust, and will void the
warranty.  Do not install the unit so that its removal will be difficult or impossible.  It may be necessary to
periodically remove the unit to clean the condenser coil.

F

 

  The best location for the WKC series
cooling unit is six (6) inches from the ceiling,
mounted on a shelf  (see above unit
specifications for weight of unit) and with no
obstruction for the evaporator cold air outlet
airflow (minimum 12 inches) and a minimum
of three (3) feet for the warm air discharge
from the exterior grille.  (see Fig. 1, 2 and 3)
It is preferred that the unit is mounted as close
to equal distance from each end of the wall as
possible.

F

  The area into which the unit exhausts must
be well ventilated.  If not, the unit will be unable to reject the excessive moisture and heat resulting in
unsatisfactory performance.

Содержание WKC Series

Страница 1: ... INSTALLED BY DATE While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specific enclosure or application must be determined by ...

Страница 2: ...es them ideal to be installed in cabinets and credenzas BREEZAIRE WKC series cooling units are not always recommended for converted closets Ask your dealer for details ENCLOSURE CONSTRUCTION GUIDELINES To use the below SIZING GUIDE the enclosure to be cooled must be built to the following minimum specifications If the enclosure cannot be built to these minimum specifications consult your BREEZAIRE...

Страница 3: ...e it will begin to run within 5 minutes of being plugged in Allow it to run for a minimum of 15 minutes There should be a flow of cool air from the lower evaporator outlet side see Fig 1 and warm air should be flowing from the rear opening on the exterior grille side see Fig 3 If there is no airflow or no change in temperature on either side contact your dealer F BREEZAIRE units should NOT be inst...

Страница 4: ...t up the cooling unit will reduce the temperature of the enclosure slowly The unit may run constantly or cycle off for short periods The time required to reach the desired temperature will vary depending on the enclosure s construction and contents The thermostat is factory set to approximately 55o Fahrenheit Unless the temperature falls below that desired do not change the thermostat setting for ...

Страница 5: ...ay cause the unit s performance to be compromised In situations where the ambient relative humidity is very low the desired enclosure relative humidity may not be achieved without adding moisture To add moisture to the enclosure only use slow natural evaporation from a small porous water container Do not use a humidifier In some cases improper placement or installation may cause the unit s perform...

Отзывы: