WK(L)06/02 PG  4

OPERATION

On initial start-up the
cooling unit will
reduce the
temperature of the
enclosure slowly.
The unit may run
constantly or cycle off
for short periods.  The
time required to reach
the desired
temperature will vary,
depending on the
enclosure
construction and
contents.

The thermostat is factory set to approximately 55°Fahrenheit.  Unless the temperature falls below that which is desired, do
not change the thermostat setting for at least 3 days.

During normal operation the (optional) Sentry III thermostat's readout will display the temperature of the air entering the
intake of the cooling unit.  If the optional bottle probe is installed the intake air sensor will be disconnected and the
temperature of the probe will be displayed.  The temperature being displayed is also the temperature used by the control
system to turn the cooling unit on and off.

After initial cool down, the "on-off" cycle should be relatively constant.  The percentage of "off " time will depend on
enclosure's construction, placement of unit, contents, and surrounding outside temperatures.  If it is necessary to adjust the
temperature of the enclosure; adjust the thermostat to a colder temperature while the unit is running and to a warmer
temperature while the unit is off.  The set point can be adjusted no lower than 48°F or higher than 63°F. NOTE:  If the
enclosure is not cooling to the current set point, lowering the set point temperature further will not help. (See ENCLOSURE
PROBLEMS section)

Adjustment of mechanical thermostat (WK Model) only requires a small clockwise turn of screw to lower the enclosure
temperature.  This screw is located on the front of unit. (See Fig. 1)  

(CAUTION) If the operation of the unit is stopped,

either by unplugging it or by turning the thermostat, do not restart it for at lease 10 minutes.

The Sentry III set point (WKL Model), desired enclosure temperature, may be changed by pressing and holding the "SET"
button while momentarily pressing the "COOLER" or "WARMER" button.  When the "SET" button is pressed the readout
will automatically change and display the current set point temperature

Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while the
unit is running the Sentry III's internal delay will be activated and the unit will not restart for approximately three (3)
minutes.  NOTE:  This delay may also occur on initial power-up.

MAINTENANCE

The 

BREEZAIRE

 

cooling unit requires very little maintenance.  To maintain optimal performance, the condenser coil

should be inspected and cleaned every 3 months.  Remove the exhaust condenser grille located outside the enclosure and
use a vacuum (with brush attachment) to remove dirt and lint from the fins of the condenser coil.

If the condenser coil becomes blocked preventing proper air flow the unit will over heat causing a loss in cooling
efficiency and will result in a failure of the unit not covered under warranty.

ENCLOSURE PROBLEMS

BREEZAIRE

 

is extremely proud of the quality and reliability of its products.  Experience has shown that of the small

number of problems encountered, the large majority are due to improper unit selection or enclosure construction.  Should
the cooling system be suspected of malfunctioning, check the temperature of the air being exhausted from the upper part of
the warm air exhaust condenser grille .  If it is warm, the unit is working.  A further check may be made by comparing the air
temperature entering the lower grille on the cold side (Evaporator side) with that leaving the upper cold side grille. (see Fig.
1)  If the air leaving the unit is 6°F or more degrees colder than the temperature entering, the unit is working properly.  In
some cases, improper placement or installation may cause the unit's performance to be compromised.

Molding

Drain Line

Shelf

Brace

(Condenser) Grill

(if required)

W*

H*

6" Min.

Top brace

Ceiling

Studs

Figure 2

*See Specifications

Wine Room

Warm Air Exhaust

WK(L) Cooling Unit

Evaporator Side

Figure 3

Seal

Warm Air Exhaust

(Condenser Side)

MINIMUM

CLEARANCE

3 FEET

Содержание WK1060

Страница 1: ..._ INSTALLED BY ______________________________ DATE__________________ While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specif...

Страница 2: ...exterior walls and ceiling insulation value should be a minimum of R 19 There should be no glass doors and or windows F All joints door frames electrical outlets or switches and any pipes or vents which go through the enclosure should be sealed to prevent air and moisture leakage into the room Concrete and brick are not insulation or moisture barriers F Doors into the enclosure should be of minimu...

Страница 3: ...ET button while momentarily pressing the COOLER or WARMER button When the SET button is pressed the readout will automatically change and display the current set point temperature Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while the unit is running the Sentry III s internal delay will be activated and the unit will not restart ...

Страница 4: ...roperly attached to the unit see Fig 3 F Make a hole through the wall as illustrated in Fig 2 The dimensions of the hole should be approximately 1 4 inch larger than the width and height given in the specifications If the unit is to be installed above floor level construct a shelf as shown in Fig 3 This shelf must be capable of supporting the weight indicated in the specifications NOTE Insulation ...

Страница 5: ...ll the paper through the door seal it means air and moisture are also entering into your enclosure Because of the temperature difference between the inside and outside very small cracks can allow large amounts of outside air into the enclosure Please be aware that moisture will pass through solid concrete brick paint paper and wood A newly constructed room may contain fresh wood paint concrete and...

Отзывы: