ROOM AIR FAN
When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes
from start-up.
RE-STARTING A WARM STOVE
If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.
After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.
After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off.
To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button.
REFUELING
We recommend that you not let the hopper drop below ¼ full. While the hopper lid is open, the unit will not feed fuel to the fire. If the
hopper lid remains open too long, the fire may go out.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.
BRECKWELL MAINTENANCE TOOL
A tool has been provided to help with the following functions:
a.
Stirring pellets in hopper
– unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur.
Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.
NOTE:
To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.
b.
Scrape ashes from burnpot.
SHUTDOWN PROCEDURE
Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The red light will go out. The blowers will continue
to operate until internal firebox temperatures have fallen to a preset level.
SAFETY FEATURES
a.
Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.
1.
To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
2.
In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing
the stove from overheating.
NOTE:
The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A service call
may be required.
b.
If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE:
Opening the stove door for more than 30 seconds during operation will cause enough pressure change to de-activate the air switch,
shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.
FIGURE 13