background image

 

 

1

1

.

.

 

 

C

C

L

L

A

A

S

S

S

S

I

I

F

F

I

I

C

C

A

A

T

T

I

I

O

O

N

N

 

 

 

Medical device class IIa 

 

Medical device class 2 

 (electrical safety) 

 

Type BF 

 

 

Level of protection IP 30: 
- protected against ingress of solid foreign objects larger than 2.5 mm; 
- not protected against vertical water drops falls. 

 

Device not to be used in presence of a mixture of inflammable anesthetic with air or oxygen or nitrous 
oxide. 

 

Expected shelf life of accessories: 1 year. 

 

Expected shelf life of the device: 5 years. 

 

Operating conditions: 

 

TRANSPORT and STORAGE 

OPERATING 

Room temperature 

+ 70 °C 

- 25 °C 

+ 40 °C 

+ 5 °C 

Relative humidity 

93 % 

15 % 

93 %  

15 % 

Atmospheric pressure 

1060 hPa 

700 hPa 

1060 hPa  

700 hPa 

 

Essential performances: 

 

Provide sufficient suction for mothers to express milk, 

 

Control the pumping rhythm to better respect the baby's sucking rhythm. 

 
Applied part: Expression Kit Kolor® 
 

Note

: the CE declaration is available on request.  

 
 
 

ELECTROMAGNETIC COMPATIBILITY 

Electro medical devices require special precautions against EMC and must be installed and set to operate 
in accordance with the EMC information provided in this manual. 
WARNING: Avoid using this unit near or stacked onto other equipment as this may cause a malfunction. If 
this is necessary, this appliance and the other appliances should be monitored for normal operation. 
WARNING:  Use  of  accessories,  transducers  and  cables  other  than  those  specified  or  supplied  by  the 
manufacturer  of  this  device  may  cause  an  increase  in  electromagnetic  emissions  or  a  decrease  in  the 
immunity of this device and cause improper operation. 
WARNING:  Portable  RF  communication  devices  (including  peripherals  such  as  antenna  cables  and 
external  antennas)  should  not  be  used  closer  than  12  inches  (30  cm)  to  any  part  of  the  FISIO  breast 
pump, including cables specified by the manufacturer. Otherwise, performance may be impaired. 
WARNING:  If  the  device  malfunctions  due  to  electromagnetic  disturbances,  the  performance  of  the 
device may be impaired and result in delayed patient care. 
Wireless  communication  devices  such  as  wireless  home  networking  devices,  mobile  phones,  cordless 
phones  and  their  bases,  walkie-talkies  can  affect  the  device,  and  it  is  recommended  to  keep them at a 
distance of at least 0.5 m from the device. 

Содержание kitett FISIO

Страница 1: ...T TR RI IC C B BR RE EA AS ST TP PU UM MP P M Mo od de el l FISIO 0459 2003 Directive 93 42 CEE Medical devices Class IIa All KITETT breastpump accessories are BPA free LA DIFFUSION TECHNIQUE FRANCAIS...

Страница 2: ...d 3 3 P PR RE EC CA AU UT TI IO ON NS S F FO OR R U US SE E 4 4 T TE EC CH HN NI IC CA AL L D DE ES SC CR RI IP PT TI IO ON N a an nd d P PE ER RF FO OR RM MA AN NC CE ES S 4 1 Operating characteristi...

Страница 3: ...o operate in accordance with the EMC information provided in this manual WARNING Avoid using this unit near or stacked onto other equipment as this may cause a malfunction If this is necessary this ap...

Страница 4: ...cles 0 UT 250 300 cycles Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m Radiated RF IEC 61000 4 3 10 V m 80 MHz to 2 7 GHz 10 V m 80 MHz to 2 7 GHz 385 MHz at 27 V m 450 MHz at 28...

Страница 5: ...wnloaded free of charge from 2 1 BREASTPUMP WITH AUTOMATIC CONTROL Rhythm and suction power are automatically controlled by the device 2 2 IDENTIFICATION Each breastpump has its own identification cod...

Страница 6: ...ctric power supply do not use it in bath or under the shower do not immerse Keep this medical device away from any high heat source Store properly the electric cord and the tubes after each use Kitett...

Страница 7: ...6ELH K30ELH K21ESDH K24ESDH K26ELDH K30ELDH Kolor funnel Small or Large size 21 24 26 or 30 mm ref WB21ES or EL WB24ES or EL WB26ES or EL WB30ES or EL Autoclavable Kolor funnel Small or Large size 21...

Страница 8: ...t and to the interface bottle on the unit Connect the unit to the mains Place the Kolor funnel on the breast and switch the device on position I All the milk is collected in the 100 ml maximum value f...

Страница 9: ...mited to external parts using a non abrasive sponge soaked with alcohol or with a disinfecting product recommended by the manufacturer Anios Surfa safe Premium If liquids or solids were introduced int...

Страница 10: ...rd case the unit stops suddenly mains cut or suction alternating defect Disconnect the tube coming from the interface bottle In case of alternating stop contact your supplier IN CASE OF ANY OTHER TRO...

Страница 11: ...rd 2002 96 CE Product on the market since August the 13 th 2005 So you contribute to the human health and environmental protection B BR RE EA AS ST TF FE EE ED DI IN NG G I IS S N NA AT TU UR RA AL L...

Отзывы:

Похожие инструкции для kitett FISIO