FLOW-TEK FTG SERIES
MANUAL GEAR OPERATOR
Installation, Operation, and Maintenance Manual
9 of 11
© 2022 BRAY INTERNATIONAL, INC. ALL RIGHTS RESERVED. BRAY.COM The Information
contained herein shall not be copied, transferred, conveyed, or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International, Inc.
> Using handwheel turn the valve to be 10-20 degrees unseated
and then open again. The gear should stop at set position
where ball bore is aligned with the seat inner diameter and
valve bore.
> For fully closed position, loosen the counter nut while holding
the adjustment stop stud with Allen wrench (Image 2).
> Loosen the adjustment stop stud by turning counterclockwise.
> Start closing the valve by rotating handwheel clockwise. Stop
when the machined square of the gear stem nut rotates 90
degrees and mark the position.
> Tighten the adjustment stop stud by hand until feeling
resistance.
> While holding the adjustment stop stud with Allen wrench
in position, tighten the counter hex nut. Do not allow the
adjustment stop stud to move.
> Using the handwheel, turn valve to be 10-20 degrees unseated
and close again. The gear should stop at the set position
where marked.
> After both stops are set, replace the seal caps and position
indicator.