BR50•10 Technical Manual 090729
© 2008 Lock Technology BV
Page 3 of 3
1
2
3
5
6
4
As TURNABLE ENTRY UNIT with NL LOCK StraightBolt lock EM35•20:
The diameter of the cable hole should be minimum 9 mm, maximum 12 mm. The hole must
be deburred well to avoid damage to the cable. Cut the grooved shaft to the appropriate
length: Measure door thickness (from mounting surface of the Entry unit to the mounting
surface of the lock) and add
40 mm
(1.6”).
Prepare the mounting and cable holes according to picture 1. Hold the bearing plate in a
way against the mounting surface that “UP ROTATE” is readable on top (picture 2). Affix the
bearing with the two mounting adapter (M4)
Do not overtighten
. Insert first the spring and
then the pin into the hole on the back cover (picture 3). Insert the grooved shaft, with the cut-
off edge first, all the way into the entry housing (picture 4). Now push the cable into the
groove until flat over the entire length of the shaft. Route the cable and shaft through the
spindle hole of the door, hold the unit at an approximately 10:00 o’clock position, and slide it
on the mounting adapters (picture 5). Turn unit clockwise until it clicks into straight position
at 12:00.
The Bravo entry unit will not be detachable once the lock is installed.
Connect one (1) battery to the battery clip. Only use 9V-ALKALINE batteries from brand
name manufacturers like DURACELL™.