Содержание SlimDP - 01

Страница 1: ...Brave SlimDP 01 Brave SlimDP 02 Brave SlimDP 04 User and Service Manual Version 2 6 Brave Door Entry System ...

Страница 2: ......

Страница 3: ... buttons For all variants is possibilities with Amplifier need external power DC 12V Brave SlimDP 01A 1 button Brave SlimDP 02A 2 buttons Brave SlimDP 04A 4 buttons Basic functions of the new line Electronic volume control without the need to open the front cover Programmable tone detection for call disconnection or repeat calls Programming with a DTMF phone or USB cable from a PC 24 digit telepho...

Страница 4: ...ame card panel 15 2 5 CONNECT THE KEYBOARD 16 2 6 CODE RELAY COSW 17 2 7 OTHER ACCESSORIES 18 2 7 1 Time Relay 18 2 7 2 Power supply 12V AC 18 2 7 3 Power supply 12V DC 18 2 7 4 USB Programming cable 18 3 DOOR ENTRY SYSTEM OPERATION 19 3 1 SIGNALLING OVERVIEW 19 3 2 CALLER AT THE DOOR 20 3 3 RELAYS REGIMES 21 3 4 PERSON IN THE BUILDING 21 3 4 1 Outbound call 21 3 4 2 Incoming call 22 3 4 3 Door En...

Страница 5: ...C PARAMETERS 31 5 4 TIME PARAMETERS 33 5 5 SYSTEM PARAMETERS 37 5 6 BASIC SETTING AND DELETION 43 5 7 END OF PROGRAMMING 43 5 8 PARAMETER OVERVIEW 44 6 TECHNICAL PARAMETERS 47 6 1 ELECTRICAL PARAMETERS 47 6 2 MECHANICAL DIMENSIONS 47 7 TABLE FOR EASY PROGRAMMING 48 8 DRILLING MASTER BOARD 52 ...

Страница 6: ...ecure lock on the switch serial activation code COSW Option to disconnect a call by the repeated pressing of a button Option to switch on a baby call regime no number dialling Option to switch on a regime to suppress the DTMF connection from the microphone Option to switch on a ticking sound into a call to announce another call Option to switch on acoustic signalling for relay connection Option to...

Страница 7: ...his signal is not available on an analogue line but the ringing tone ends and a connection begins It is difficult to identify the exact moment this occurs Code lock Function for relay connections by inputting a combination of up to 4 buttons or keyboard keys after pressing the key symbol Code relay between Doorphone Brave and the electric lock can be connected code relay COSW CodeSwitch which is l...

Страница 8: ... basic models Brave SlimDP 01 1 button Brave SlimDP 02 2 buttons Brave SlimDP 04 4 buttons models with amlifier Brave SlimDP 01A 1 button Brave SlimDP 02A 2 buttons Brave SlimDP 04A 4 buttons Itegrated amplifier is only HW solution all programable parameters is same Parameters that are not specified in this manual is not recommended to change because they are not available for the version of Brave...

Страница 9: ...is supplied with a special key which is used to release the name cards on the front panel Push the key into the hole in the speaker grille see figure 1 2 Push the name card panel down and then push it towards to grille see figure 2 3 The panel will be released Pull it towards you to remove see figure 3 2 1 2 Uncover control elements 4 Push the aluminium speaker grille down see figure 4 ...

Страница 10: ...nd wood may require special screw types To power the unit for voice connect the telephone wires into the terminal on the right side Using either a standard analogue phone line or an analogue extension on a PBX For the external power supply connect to the terminal 12V external power supply AC min 10V max 18V or DC min 12V max 24V The energy consumption of a connected electrical magnetic lock 0 5A 1...

Страница 11: ...rcuits on the board For the variants of lock connection see the picture below Wiring of standard and magnetic inverse lock 7 A special USB cable enables the doorphone to be connected to a PC for programming of individual parameters A dedicated Windows program is included on the CD requires version W98SE or higher Under no circumstances use 120V or 230V direct current DC This can be solved by the u...

Страница 12: ...rformed by ordinary phone DTMF tone dial The switch is The PCB heating has two major benefits Firstly it warms the board during winter time temperatures under 20 C most circuits have warranty operation down to 20 C and secondly it helps to protect the PCB against humidity when installed outside Note Door entry system Brave SlimDP is designed in such a way that it is possible to connect 10 18V AC o...

Страница 13: ...t where is a strong ambient noise at the phone and quiet environment at the communicator Here we leave the parameter value of 72 7 and 73 and 71 parameters set as follows parameter71 11 to 14 and 73 2 to 4 The principle of settin parameters is signal from the microphone is amplified by the sum of parameters 72 71 volume of microphone and signal to the speaker is amplified by the sum of parameters ...

Страница 14: ...ntrol and setting elements are located under the speaker front aluminium grille PC connector SlimDoorPhone fixing screw hole Service switch Loudspeaker Heating activation 12V for relay light and heating Relay Telephone line connection Microphone Buttons Hole for lead in cable LED for lighting ...

Страница 15: ...ing 2 4 Final closing of Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if required 2 4 2 Replacing name card panel 2 Push key into hole in speaker grille as far as possible see figure 2 3 Push name card panel upwards and push the bottom edge in see figure 3 ...

Страница 16: ... possible control from phone during conversation too parameter 30 Code lock for relay in Doorphone from buttons stays conserved Connection by special cable is make that way will you use programming connectors 8pin To programming from PC is usings same USB cable USB KABslim and program ID Manager is in new version 2010 equipped also by program for setting keyboard To basic function is necessary hav...

Страница 17: ...y Brave is set in several codes to activate the relay code Relay can be activated codes for one or two impulses can differentiate activated from the phone DTMF or from keys keyboard The last option is the activation code in another mode switch than the lock The code information is 8 bits but the code is 4 bits with security 4 bits which is total of 8 bits Practically this is performed so that afte...

Страница 18: ...delivery and must be ordered separately Further details of power supplies and electric locks can be found at www alphatech cz 2 7 3 Power supply 12V DC A 12V 1A DC alternative power supply is recommended for the Brave SlimDP version with amplifier This is not a part of delivery and must be ordered separately Further details of power supplies and electric locks can be found at www alphatech cz 2 7 ...

Страница 19: ...1200 1067 800 Confirmation of command from the phone 800 Ticking during a call Notice about the end of a call 1333 Relay switch signal Modulated Entry into programming from the phone 980 1067 1180 Programming from the phone Modulated Parameter confirmation 800 Entry into programming from the PC 980 1067 1180 Line connection Reset 1850 1067 1850 Error generally something is not right 800 Empty memo...

Страница 20: ...45 46 Regime 2 groups of numbers the first press of the button always dials a number set in parameter 1 Following the repeated pressing of the same button when it detects a busy tone 10sec after choice or after a pre set number of rings parameter 56 the system dials a number from the second group parameter 2 After another press of the same button the system will again dial the number from the firs...

Страница 21: ... of the button Any number of button other than in 311 3116 Button set in 311 or 312 3116 Note t1 time of connection of relay 1 parameter 371 t2 time between impulses of relay 1 parameter 301 Tab 1 Table of relay controls 3 4 Person in the building The person in the building means the person who is in telephone contact with the Brave entry system i e Mr Smith 3 4 1 Outbound call An outbound call is...

Страница 22: ...so possible to input and a service password parameter 44 directing the system to go to the programming regime Another exception is during incoming call and DIP1 is switched to on SERVIS when the system also goes to the programming regime without a service password The final exception is relay controls parameter 381 when an incoming call can disable the relay controls 3 4 3 Door Entry System with k...

Страница 23: ...get to put DIP switch to position off at the end 4 1 2 Parameter programming The default state for programming is announced with a programming tone the Brave always returns to this state after a specified time 5sec whether you started programming or not There are two types of parameters used during programming These are parameters with a fixed length which is the majority of them when programming ...

Страница 24: ...limDP to the line Connect Brave SlimDP to the PC via the USB cable The Brave will pick up a line and within 3 seconds a tone for programming entry will be heard see chapter 3 1 Page 19 Run programme BraveSet Until the USB is disconnected the Brave is connected to the PC and is in programming regime and will not run any other operations If you lose connection you will need to reconnect the USB cabl...

Страница 25: ...s of the first group or numbers of the regime Day Basic settings never change or delete these saved numbers Parameter Value Meaning Basic 2 tt nn number nn under button tt tt button number memory always input 2 digits 01 04 nn telephone number as long as 24 digits that are to be saved For saving of other sign choices always use the assignation as per the table Numbers saved in parameter 2 are numb...

Страница 26: ...iding gates m 2 is switched on for time when the line is picked up camera switches on when system picks up and off when it disconnects m 3 is switched on for time when the line is picked up and extra time t1 after disconnection lights switches on for time when the line is picked up and extra time t1 after disconnection for this time the line is busy m 4 regime button switched on when any button is...

Страница 27: ...ight if the regime 2 groups of numbers is set the system is constantly in regime DAY There are several rules that needs to be followed when setting a password Choose the first button of password from buttons that are the least used for direct dialling prolonging time Be mindful about conformity of numbers i e when 1 password contains another Note When setting parameter 32 33 34 signs and and 5 6 7...

Страница 28: ...one there is an option to input a where a is a single number and the star represents an empty space and must be in the first place Switching a relay on with 2 impulses is used for sliding gates replacing a gate entry Example Command for switching on 1 st relay 1 impulse is for example 8 the command for disconnection is 8 and the command for switching on 1 st relays 2 impulses is 9 Programming 351 ...

Страница 29: ...n relay r 2 impulses time t2 01 99 105 205 r relay number relay number 1 in SlimDP 2 in Slimey zz time t2 between first and second impulse for switching on relay 1 2 spaces 00 99 where time 00 means 0 5sec Parametr Value Description Default 3 0 p p 1 enabled disabled p 0 connection code relay COSW 0 1 0 p turns on transmission serial code to activate the first relay CAUTION at activation this func...

Страница 30: ... 0000 abcd Brave sends a serial code for the code relay COSW after evaluation code from keys keyboard namely for 2 pulses Parametr Value Description Default 3 4 abcd activation code 2 pulses from phone 0000 1111 0000 abcd Brave sends a serial code for the code relay COSW after evaluation code from telephone DTMF namely for 2 pulses Parametr Value Description Default 3 5 abcd activation code from o...

Страница 31: ...2 spaces 1 It is advantageous to set the same command for relay switching on parameter 35 36 and command for the Brave disconnection aa bb or aa cc 1 command is always 2 digits but if you wish to control relay with a single digit from the phone there is an option to input a where a is a single number and the star represents an empty space and must be in the first place e g at parameters 35 36 Para...

Страница 32: ...in the first place e g parameters 35 36 Note The Day Night switch over regime stays set following line disconnection Parameter Value Meaning Basic 47 e Regime system choice 0 1 1 e Choice of regime numbers e 0 selects numbers from first and second group e 1 selects numbers in accordance with the Day Night regime WARNING setting this parameter materially affects the number dialling Parameter Value ...

Страница 33: ...m the phone parameter 42 The setting of this time is in accordance with the adjacent table Parameter Value Meaning Basic 53 w Time between button presses 1 9 2 w maximum time in seconds between button presses range 1 9 Normal buttons Relay switch on if the time between presses is longer than time w then the code will not work correctly Choice of number if the pressed button is the first number of ...

Страница 34: ... hh then it will disconnect range 04 99 It repeats the choice if the regime of dialling 2 groups of numbers is set Parameter Value Meaning Basic 500 x Medium frequency of tone detector 1 0 3 375 475Hz 501 y Number of busy tones 2 0 4 502 z Time length of permanent tone 1 5 3 3s x Medium frequency of tone detector is set if there is a non standard signal from the telephone switchboard y Minimum num...

Страница 35: ... is specified by the formulae the entered number x 10 time length of gap ms range 04 16 which is 40 160ms f Length of flash is specified by the formulae the entered number x 100 time length Flash ms range 1 6 which is 100 600ms p Length of pause is specified by the formulae the entered number x 100 400 time length of pause ms range 1 0 which is 500 1400ms Time p is the simultaneously length of gap...

Страница 36: ...e DTMF 0 1 0 509 S Listening in DTMF level 1 4 2 p Preemphase is the ratio of the upper and lower groups of DTMF frequencies It is possible to choose ratio 2 2 dB p 0 Europe or ratio 3 2dB p 1 Australia s Choice of DTMF volume levels 4 levels Volume in DTMF dB s choice 15 1 9 2 3 3 3 4 ...

Страница 37: ... z 2 Pick up and disconnection signalisation on intro concl type2 Parameter Value Meaning Basic 63 u Acoustic ticking signal during a call 0 1 0 Ticking during a call is switched off as standard However by switching it on you can differentiate on the switchboard a call from the Brave by a faint ticking The values are u 0 Ticking into a call is off u 1 Ticking into a call is on Parameter Value Mean...

Страница 38: ...firmation and a call is activated as if there were a number Warning During the first 10 seconds of a call the tone detector is inactive there is a pause before the switchboard responds or number dialling by the switchboard Default is off m 0 By enabling the m 1 mutes the acoustic path at close relay 1 or 2 in electric lock modes 1 and 5 This feature is there because if you often use code lock func...

Страница 39: ...g Siemens 0 1 0 This function is off as standard t 0 By switching this function on t 1 the processor goes into sleep mode immediately after the line connection and after 3 secs The Brave initialises The line connection after the power supply connection is then delayed state switching on restarting of the switchboard If this function is not working and the telephone switchboard still identifies a l...

Страница 40: ...gnal for the end of a call If you don t press anything for 5 seconds then the set value is saved and you hear a confirmation tone WARNING Default values are set by the manufacturer and it is not recommended that you change them unless absolutely necessary Parameter Value Meaning Basic 74 c Soft transition of switch over 0 1 1 This function is set to off as standard c 0 it is a character of the sem...

Страница 41: ... higher the sensitivity of the microphone In noisy surroundings it is recommended to use a higher value with combination of parameters 71 75 77 Parameter Value Meaning Basic 77 s Speed of switching over voice atomisation 1 4 4 is the slowest 2 Parameters 75 76 describes the principle of acoustic feedback and the speed with which the circuit switches over the quality of incoming or outgoing sounds ...

Страница 42: ...used by a conduit This function is switched off as standard k 0 but it is possible to set on 2 levels depending on the current that switchboard can supply short circuit current I0 Switchboard current I0 k choice Function off 0 20mA 50mA 1 45mA 75mA 2 Parameter Value Meaning Basic 70 uu Level of signal transmission v dBm 04 16 10 uu The signal transmission range to the line is 4 to 16dBm entered is...

Страница 43: ...only 4 85 Basic setting only for parameters 5x only 5 86 Basic setting only for parameters 6x only 6 87 Basic setting only for parameters 7x only 7 Parameters 81 and 82 deletes all numbers saved in the button memory Parameters 83 87 deletes selective basic setting for parameters starting with 3 4 5 6 7 Values for the basic setting are stated for each parameter in the right hand column Basic WARNIN...

Страница 44: ... r 1 impulse 00 99 0 9 155 266 36 r cc command aa from the phone for switching on relay r 2 impulses 00 99 0 9 150 260 37 r ss time ss sec of relay r switch on for time t1 01 99 105 205 38 r p Control of relay r during incoming call 0 1 11 21 30 r zz period zz sec between impulses for switching on 2 impulses of relay r time length t2 01 99 105 205 3 0 p p 1 enabled disabled p 0 connection code rel...

Страница 45: ...equency of tone detector 1 0 3 375 475Hz 501 y Number of busy tones 2 0 4 502 z Length of time for permanent tone 1 5 3 3s 503 tt Length of time for DTMF tone choice 04 16 10 100ms 504 mm Length of time for gap between DTMF tones 04 16 10 100ms 505 f Length of time Flash 1 6 1 100ms 506 p Length of time for pause inter digit gap 1 0 4 800ms 507 uu Level of transmission of DTMF choice v dBm 04 16 1...

Страница 46: ...und noise 0 1 1 76 b Threshold for switching on the microphone 1 4 4 is the highest 2 77 s Speed of switching over voice atomisation 1 4 is the slowest 2 78 l VA characteristic for line connection 0 1 1 79 k Compensation for loss of conduit depending on line current 0 1 2 1 70 uu Level of signalisation transmission in dBm 04 16 10 8 Basic setting provide 81 Deletes all numbers in 1st group regime ...

Страница 47: ...or min 10 25 V Impulse choice 40 60 ms Level of tone choice 6 a 8 dB 1 20 60 mA Sensitivity of tone choice min 40 dB 20 60 mA Sensitivity of tone detector min 30 dB 20 60 mA Power supply for name tag back lighting relay heating and current circuit for exit button 12V DC 12V 24V 12V AC 10V 18V Max off take of backlighting and heating 250mA 12Vss Max Voltage of relay contact 48V When I 1A Max Curren...

Страница 48: ... 2gr 202 24 Number under button 3 Night 2gr 203 24 Number under button 4 Night 2gr 204 24 Relay 1 works in mode m 1 6 311 1 Passw for relay 1 1 imp Day Night 3211 6 Passw for relay 1 1 imp Day Night 3212 6 Passw for relay 1 1 imp Day Night 3213 6 Passw for relay 1 1 imp Day Night 3214 6 Passw for relay 1 1 imp Day Night 3215 6 Passw for relay 1 2 imp Day Night 321 6 Passw for relay 1 1 imp Day 331...

Страница 49: ... 0000 1111 3 3 4 code for activation 2 imp phn 0000 1111 3 4 4 code for activation other mode 0000 1111 3 5 4 Type of choice tone imp 0 1 41 1 Sign for prolonging of call 42 1 Brave disconnection from phone 00 9 431 2 Brave disconnection from phone 00 9 432 2 Service password 0000 9999 44 4 Command for switch over to DAY 00 9 45 2 Command for switch over to NIGHT 00 9 46 2 Regime system choice 1 0...

Страница 50: ...Intro Concl 0 1 62 1 Acoustic sign ticking 0 1 63 1 Signal tone turning on relay 0 1 65 1 Suppression of reception from microphone 0 1 66 1 Baby Call 0 1 67 1 Mute at the lock activated 0 1 68 1 no of buttons on the panel Type dependant 6 1 Delayed start Siemens 0 1 6 1 Reception volume TRH 01 16 71 2 Transmitting volume MIC 01 16 72 2 Speaker volume SPK 01 16 73 2 Soft transition of switch over 0...

Страница 51: ...ant that warranty claims are handled through your dealer Warranty claims should be accompanied by The product in question A description of the problem Proof of purchase and Your full name and address The warranty does not cover Mechanical chemical thermal or any other faults cause by the user Faults caused by natural disasters Faults caused by repairs or changes made by the user or any other autho...

Страница 52: ...8 Drilling master board ...

Страница 53: ... JR 2013 Version 2 6 X 13 ...