If the resistance value is not normal, replace the heating element. After
replacing heating element, please check as follow.
1.
Measure the resistance value between pins 4&1 or 2, pins 5&1 or 2,
pins 6&1 or 2, pins 6&4 or 5. If it is not ∞, the heating element and
sensor are touching. This will damage the P.W.B.
2.
Measure the resistance value ‘a’, ’b’, and ‘c’ to confirm that the lead
wire are not twisted and that the grounding wire is properly
connected.
3.
To confirm that the clasp
⑨
is clasped with heating element
⑩
.
No.
Part Name
Instruction
1
Nut
2
Tip Enclosure
3
Soldering Tip
Refer to the last page
4
Nip
Nipple
5
Cord Cover
6
Handle Cover
7
Handle
8
Terminal Board
9
Clasp
10
Heater Combination
11
Vibrator Switch
12
Pin 6 Connector
Metal
13
Sensor Spring
14
Heating Element
15
Sensor Element
Содержание QU376D