Fitting the static floor anchorage

Fit and use

1. 

Mark out the chosen floor anchor positions.

2. 

Drill an 11mm diameter hole through the finished floor, ply and steel flooring

.

3. 

From the top surface of the floor, counter bore the 11mm dia. hole to a diameter of

 

35mm and a depth of 13mm. 

 

4. 

Clear the debris and install the floor anchors as shown in Fig 3, with the anchor slot 

orientated as shown in Fig 4.  Tighten to a torque of 25-30Nm from underneath, 

using the nut and underfloor spreader plate.

5. 

If you need to modify the spreader plate to clear an obstruction, always leave as 

much material as possible around the bolt hole.  Any modification must be made 

such that the original load spreading properties are retained. Further reinforcement 

may be required to meet minimum vehicle strength recommendations. Contact 

the vehicle manufacturer for further advice.

6.  Note:

 It may be necessary to provide fillers between the vehicle floor convolutions

 

to prevent these from being crushed when tightening up on the nut/cap screw. 

7. 

It is recommended that some type of body sealant or foam fill be used between the

 

under floor spreader plate and the vehicle under side to prevent ingress of water 

and subsequent damage.

 

It is essential that the slot in each floor anchor is orientated as shown in Fig. 4

8

S10

Содержание STATIC SOLO ANCHOR

Страница 1: ...STATIC SOLO ANCHOR User Manual EN Instructions for fitting and use...

Страница 2: ...performance and safe operation Keep the manual in a safe place so that you can refer to it when necessary If you have any questions about your equipment please contact us Once again thank you for pla...

Страница 3: ...Fit and use After care General guidance Installation planning Fitting the static floor anchorage Equipment storage and maintenance Warranty 4 6 8 10 10 3 S10 EN Index Declaration of conformity at the...

Страница 4: ...r The installer is responsible for ensuring that the fitting meets all applicable regulations If in doubt about the method of installation or use please contact BraunAbility Ensure that the wheelchair...

Страница 5: ...Plastic Bolt Cap M10 x 60 ISO Grade 12 9 Socket Head Cap Screw Solo Anchor 50mm Diameter Under Floor Spreader Plate M10 Nyloc Nut 5 S10 EN Fit and use...

Страница 6: ...re line If these clear space dimensions cannot be provided then any structure protruding into this space should be adequately padded and comply with impact performance requirements of ECE Regulation 2...

Страница 7: ...Figure 1 Figure 2 7 S10 EN Safety information...

Страница 8: ...obstruction always leave as much material as possible around the bolt hole Any modification must be made such that the original load spreading properties are retained Further reinforcement may be requ...

Страница 9: ...Vehicle floor Floor decking or carpet Figure 3 Figure 4 9 S10 EN Fit and use...

Страница 10: ...bility equipment when used with BraunAbility branded anchorages or as instructed BraunAbility have also participated in test programs with other manufacturers anchorage products and will support warra...

Страница 11: ...ad Martock Somerset TA12 6EY UK Phone 44 1935 827740 E mail info braunability eu www braunability eu Declares that the products S10 Accredited by URS as testing laboratory in accordance with ISO IEC 1...

Страница 12: ...tock Somerset TA12 6EY UK Phone 44 1935 827 740 E mail info braunability eu www braunability eu UI1564F BraunAbility UK Ltd Unwin House The Horseshoe Coat Road Martock Somerset TA12 6EY UK Phone 44 19...

Отзывы: