Braun TempleSwipe BST200US Скачать руководство пользователя страница 5

3

English

The individual being measured should be indoors for 30 minutes before taking a 
measurement. External temperature can impact skin temperature.

This TempleSwipe™ Thermometer consists of high-quality precision parts.  

DO NOT drop the instrument. Protect it from severe impact and shock. 

Please consult your physician if you see symptoms such as unexplained 

irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, 
seizure, muscle pain, shivering, stiff neck, pain when urinating, etc. 

Even in the absence of fever, those who exhibit a normal temperature may still 

need to receive medical attention. People who are on antibiotics, analgesics, 
or antipyretics should not be assessed solely on temperature readings to 
determine the severity of their illness.

Temperature elevation may signal a serious illness, especially in neonates and 

infants, or in adults who are old, frail, or have a weakened immune system. 
Please seek professional advice immediately when there is a temperature 
elevation and if you are taking temperature on:

•  Neonates and infants under 3 months (Consult your physician immediately if 

the temperature exceeds 99.4 °F [37.4 °C])

•  Individuals over 60 years of age (Fever may be blunted or even absent in 

elderly Individuals.)

•  Individuals having diabetes mellitus or a weakened immune system (e.g., 

HIV positive, cancer chemotherapy, chronic immunosuppressant treatment, 
splenectomy)

•  Individuals who are bedridden due to stroke, chronic illness, surgical recovery, 

paraplegia, quadriplegia.

•  A transplant recipient (e.g., liver, heart, lung, kidney)

It is important to know each individual’s normal temperature when they are well. 
This is the only way to accurately diagnose a fever. Take multiple readings when 
healthy to determine normal temperature. 

This thermometer is not intended for pre-term babies or small-for-gestational 
age newborn (birth to 4 weeks of age) babies. Pre-term is defined as babies 
born before 37 weeks of gestation.  Small-for-gestational-age is defined as 
a newborn baby, born at 37 weeks or later, with a weight below the 10th 
percentile for newborn babies of the same gestational age.

This thermometer is not intended to interpret hypothermic temperatures.
DO NOT allow children to take their temperatures unattended.
DO NOT modify this equipment without authorization of manufacturer.
This thermometer is intended for household use only. 

Use of this TempleSwipe™ Thermometer is not intended as a substitute for 
consultation with your physician or pediatrician.

Содержание TempleSwipe BST200US

Страница 1: ...TempleSwipe Thermometer BST200US...

Страница 2: ...ynch Blvd Suite 300 Marlborough MA 01752 Cont ctenos Preguntas o Comentarios Ll menos lada gratuita al 1 800 327 7226 Correo Electr nico ConsumerRelations HelenofTroy com Visite www BraunHealthcare co...

Страница 3: ...1 English Touch 5 6 1 2 3 4 Protective scanner cap Scanner Battery door LCD screen Temperature button Power button 1 2 3 4 5 6...

Страница 4: ...r 12 years NEVER use the thermometer for purposes other than those it has been intended for Please follow the general safety precautions when using on children NEVER immerse the TempleSwipe Thermomete...

Страница 5: ...9 4 F 37 4 C Individuals over 60 years of age Fever may be blunted or even absent in elderly Individuals Individuals having diabetes mellitus or a weakened immune system e g HIV positive cancer chemot...

Страница 6: ...ren and adults Auto Display memory The last reading is automatically displayed for 2 seconds when the unit is switched ON How the Braun TempleSwipe Thermometer works The TempleSwipe Thermometer measur...

Страница 7: ...s green for a normal temperature yellow for a fever and red for a high fever Color range Green Yellow Red Reading 96 4 F 99 4 F 35 8 C 37 4 C 99 4 F 101 3 F 37 4 C 38 5 C 101 3 F 38 5 C Meaning Normal...

Страница 8: ...d for the duration of the measurement When the temperature button is pressed a dashed line will appear on the screen and a soft beeping is heard to let you know the thermometer is working DO NOT remov...

Страница 9: ...carefully clean the sensor and wait for 5 minutes before taking a measurement on another Individual Wiping the forehead with a warm or cool cloth may impact your reading It is advised to wait 15 minu...

Страница 10: ...positioning with positive and negative as shown Replace the battery door and close securely Replace the batteries when the flashing battery symbol appears on the LCD screen Dispose of batteries accor...

Страница 11: ...n If the steady battery icon is the only symbol shown on the display the device cannot work Blank display Thermometer does not have power All segments display or Blank display System error Error messa...

Страница 12: ...is warranty applies only to the original purchaser of this product from the original date of purchase B At its option Kaz will repair or replace this product if it is found to be defective in material...

Страница 13: ...s ASTM E1965 98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature ISO 80601 2 56 Medical electrical equipment Part 2 56 Particular requirements for...

Страница 14: ...elow The customer or the user of the BST200 should ensure that it is used in such an environment The BST200 equipment is intended for use in the electromagnetic environment specified below The custome...

Страница 15: ...13 English...

Страница 16: ...14 Touch 5 6 1 2 3 4 Tapa protectora del escaner Esc ner Tapa de la bater a Pantalla LCD Bot n de temperatura Bot n de encendido 1 2 3 4 5 6...

Страница 17: ...iga las precauciones generales de seguridad cuando se use en ni os NUNCA sumerja el TempleSwipe de deslizamiento en agua u otros l quidos no es a prueba de agua Para limpieza y desinfecci n por favor...

Страница 18: ...iebre puede ser baja o ausente en individuos de edad avanzada Individuos con diabetes mellitus o un sistema inmunol gico d bil p ej VIH positivo quimioterapia contra el c ncer tratamiento cr nico inmu...

Страница 19: ...uda a reducir la propagaci n de g rmenes Totalmente seguro para usar en ni os y adultos Memoria con Visualizaci n Autom tica La ltima lectura se muestra autom ticamente durante 2 segundos cuando se en...

Страница 20: ...n el color que se indica en la pantalla La pantalla muestra verde para temperatura normal amarillo para fiebre y rojo para fiebre alta Rango de Color Verde Amarillo Rojo Lectura 96 4 F 99 4 F 35 8 C 3...

Страница 21: ...s contra la frente durante la medici n Cuando se presiona el bot n de temperatura aparecer en la pantalla una l nea punteada y se escuchar un suave pitido para hacerle saber que el term metro est func...

Страница 22: ...lcohol para limpiar cuidadosamente el sensor y espere 5 minutos antes de tomar una medici n en otro paciente Limpiar la frente con un pa o tibio o fr o puede afectar la lectura Se aconseja esperar 15...

Страница 23: ...e 2 pilas AAA coloc ndolas correctamente con positivo y negativo como se muestra Vuelva a colocar la tapa de las pilas y cierre bien Cambie las pilas cuando aparezca el s mbolo de pila parpadeando en...

Страница 24: ...e la pila es el nico s mbolo que se muestra en la pantalla el dispositivo no puede funcionar Pantalla en blanco El term metro no tiene poder Todos los segmentos se muestran en la pantalla o pantalla e...

Страница 25: ...guiente es posible que estas limitaciones o exclusiones no se apliquen en su caso Esta garant a le confiere ciertos derechos legales espec ficos Es posible que usted tambi n tenga otros derechos legal...

Страница 26: ...ntinuaci n El cliente o el usuario del BST200 debe asegurarse de que se utilice en dicho entorno El equipo BST200 est indicado para usar en el entorno electromagn tico que se especifica a continuaci n...

Страница 27: ...na se al de onda cuadrada del ciclo de trabajo del 50 Como alternativa a la modulaci n FM puede usarse una modulaci n de pulsos del 50 a 18 Hz porque si bien no representa una modulaci n real ser a el...

Страница 28: ...os Infrarrojos para la Determinaci n Intermitente de la Temperatura del Paciente ISO 80601 2 56 Equipo El ctrico M dico Parte 2 56 Requisitos part culares para la seguridad b si ca y el rendimiento es...

Страница 29: ......

Страница 30: ...28...

Страница 31: ...20 50 matte text 80 gloss cover Revision 9 Release Date Date 15APR20 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Magenta 0 Yellow 0 Black 100 PMS GOE 63 1 4 Helen...

Отзывы: