background image

Page 24

Lift Operating Instructions

Lift Power

On/Off Switch

Power

Indicator

Light

Before lift operation, park the vehicle on a level 

surface, away from traffic.  Place the vehicle 

transmission in “Park” and engage the parking 

brake.

Manual Door(s):  Open manual doors fully and 

secure in full open position before operating the 

lift.  

Power Door(s):  Open and close power door(s) 

using the pump module OPEN/CLOSE switch, 

or optional remote control.  Optional power 

door(s) cannot be activated using the hand-

held pendant. 

Do not operate the lift if you suspect lift 

damage, wear, or any abnormal condition.  

Refer to the Manual Operating Instructions to 

manually operate lift. 

Hand-held

Pendant Control

36514

Lift Power On/OFF Switch:  This switch must be 

in the ON position in order to activate the lift.  The 

green Power Indicator Light illuminates to signal 

power to the lift.

      UP:  From ground level, the UP function will   

      raise (rotate) the roll stop to the vertical 

position.  The platform then raises to floor level 

position.

      DOWn:  

From floor level,

 the DOWN function 

      lowers the platform to ground level and then 

unfolds (lowers) the roll stop to the ramp (horizon-

tal) position.

Control Switch Functions:

Hand-held Pendant Control:  The hand-held 

attendant’s pendant control is equipped with two 

rocker switches.  When there is power to the lift, 

the lift function labels illuminate to identify the 

functions.

         FOLD:

  From floor level, the FOLD function 

         folds the platform inward to the stowed

position.

         UnFOLD:  From stowed position, the 

         UNFOLD function unfolds the platform out-

ward to the floor position.

Note:  If any functions do not occur as 

described, discontinue lift use immediately. 

 

Содержание L952SE2740IB-2

Страница 1: ...t 2013 Original Instructions Original Instructions ISO 9001 2008 www braunability com international 631 West 11th Street Winamac IN 46996 USA Phone 1 574 946 6153 Fax 1 574 946 4670 SE SE 2 Millennium...

Страница 2: ...edom for years Thank you again for your business and enjoy your independence Sincerely The Braun Employee Family XXXXXXXXXX INDIANA USA The Braun Corporation MFG DATE XX XXXXX SERIAL NUMBER MODEL NUMB...

Страница 3: ...nstruction Decal 15 Platform Angle Adjustment 16 Tower Microswitch Adjustment 17 18 Installer Verification 19 20 Lift Operation Safety 21 23 Lift Operating Instructions 24 28 Manual Operating Instruct...

Страница 4: ...ock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a condition where...

Страница 5: ...y and or property damage WARNING WARNING Read this manual supplement s and lift posted operating instructions decals before performing installation operation or service procedures Use appropriate pers...

Страница 6: ...r electric shock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a con...

Страница 7: ...torms or similar electrical phenomena Use caution when operating this equipment in severe weather or environmental conditions fog rain snow ice dust etc Discontinue lift use immediately if any lift or...

Страница 8: ...n powered electric wheelchairs off when on lift platform Press the DOWN switch until the entire platform rests on ground level lowered fully and the roll stop is fully unfolded ramp position before lo...

Страница 9: ...This equipment will withstand or has been protected against transportation and storage temperatures of 25 C to 55 C and for short periods of up to 70 C The lift has been packaged to prevent damage fr...

Страница 10: ...f Gravity is the intersection of X Y and Z Lift Model X cm Y cm Z cm L955SE3143IB 2 L955SE3455IB 2 L952SE2740IB 2 64 84 64 84 55 14 45 97 60 20 48 26 21 37 21 37 18 46 Notice X must be measured from o...

Страница 11: ...use of equipment other than instructed in this manual is prohibited UP DOW N 32819 FOLD UNFO LD 32820 Pump Module Hand Held Pendant Control Top Parallel Arm 2 Adjustable Quiet Ride Stow Block 2 Verti...

Страница 12: ...ing as shown in Figure C Close the vehicle door s Position lift as close to the door opening as possible while maintaining a minimum clearance of 12 mm between the lift and the door or wall See Figure...

Страница 13: ...lar 90 to the vehicle floor except when base plate wedges are used Step well Installations It is not permissible for the base plate to overhang the step well Base plate support must be constructed in...

Страница 14: ...ion detail below Mounting Bolt Torque Tar get 40 Nm Check for obstruc tions such as gas lines wires exhaust etc before drilling or cutting Failure to do so may result in serious bodily injury and or p...

Страница 15: ...rill 28 5mm diameter grommet access hole Check under the vehicle for obstructions 2 Insert grommet Secure grommet with two self tap screws 3 Route ground and power cables through grommet Route cables...

Страница 16: ...Cables Pump Ground Cable Route the pump mounted cable through the floor grommet and connect to a vehicle fram ing member as shown See Figure J Vehicle Battery Ground Cable A 4 gauge 21 1mm2 ground ca...

Страница 17: ...WAKE UP SIGNAL WHEN A CONTROL FUNCTION IS ACTIVATED 9 3 LIFT SIGNAL OPTIONS Install 32638A in cavity 5 LIFT NOT STOWED 7 LIFT STOWED 9 LIFT STOWED Lift Pump Module Note Pins 5 and 9 are 3 Amp Max Pin...

Страница 18: ...stop blocks are mak ing full contact with the vertical arms see photo at right Floor Level Adjustment Following platform angle adjust ment set floor level positioning as detailed in Tower Microswitch...

Страница 19: ...Should be an approximate 3 mm clear ance between outboard end of rotating pivot slide arm saddle and the lower parallel arm See Photo B Tower 2 Up Switch Adjustment Floor Position from Below Floor 1 L...

Страница 20: ...iew the Tower 4 microswitch inside the lift tower see Photo D Turn the switch adjust ment screw in or out as needed until the radius of the microswitch blade rides on the apex of the activation plate...

Страница 21: ...15 minute test period Verify that the vertical drift of the platform between the two measurements has not exceeded 15mm Verify that the angular drift of the platform between the two measurements has n...

Страница 22: ...ration below Loosen 9 16 hex nut on the relief valve adjustment screw do not remove hex nut 6 Turn adjustment screw clockwise 1 8 turn 7 Press UP switch and verify lift is able to operate throughout i...

Страница 23: ...or electric shock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a co...

Страница 24: ...trical storms or similar electrical phenomena Use caution when operating this equipment in severe weather or environmental conditions fog rain snow ice dust etc Discontinue lift use immediately if any...

Страница 25: ...rn powered electric wheelchairs off when on lift platform Press the DOWN switch until the entire platform rests on ground level lowered fully and the roll stop is fully unfolded ramp position before l...

Страница 26: ...tch must be in the ON position in order to activate the lift The green Power Indicator Light illuminates to signal power to the lift UP From ground level the UP function will raise rotate the roll sto...

Страница 27: ...ch Arm UP DOWN Switch A spring loaded sliding switch is built in the switch arm Slide the switch knob out to the UP position to raise the platform Slide the knob in to the DOWN position to lower the p...

Страница 28: ...or s are fully open Release switch Manual Door s Manually open door s fully and secure A B TO UNFOLD PLATFORM C D Press orange OUT switch see Photo B until platform stops unfolds fully reaches floor l...

Страница 29: ...d L I J K L 2 Press red DOWN switch until the entire platform reaches ground level stops and roll stop unfolds fully see Photos H and I Release switch Switch Arm Switch Slide knob in to DOWN position...

Страница 30: ...latform Roll stop must be UP and roll stop latch must be fully engaged UP AI 26797 001 O P 3 Unlock wheelchair brakes and load passenger from platform into vehicle Note Lower head to clear door jamb h...

Страница 31: ...Open Down Close Up Stop D Release Valve maximum 3 Nm minimum 2 Nm seats stops O P E N C L O S E AI B P Valve 1 30 92 O P E N C L O S E approximate 1 5 mm intervals Valve Tightening Specification Once...

Страница 32: ...lease valve and turn counterclockwise open 1 4 turn only until the platform reaches ground level and the roll stop unfolds See Photo C Down To Lower Using hand pump handle a Place slotted end of pump...

Страница 33: ...ge 31 E Stop Lift Power Switch Emergency Stop E Stop Operating Instructions To Activate E Stop Push E Stop button down To Reset E Stop 1 Turn lift power OFF 2 Pull E Stop button up 3 Turn lift power O...

Страница 34: ...e surrounding area before applying lubricants Clean only with mild detergent and water Do not clean with solvents Allow the lift to dry thoroughly and apply lubricants as specified after every cleanin...

Страница 35: ...ints 2 LO Parallel Arm Pivot Pin Bearings 16 LO Lift Tite Latch Dampening Spring 2 springs 4 Points LO Hydraulic Cylinder Pivot Bushings 8 LO Roll Stop Lever Bearings 2 LO Roll Stop Latch Pivot Point...

Страница 36: ...agram Apply Light Grease to both sides of slot See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Resecure...

Страница 37: ...ndrail pivot pin bearings 4 Hydraulic cylinder pivot bushings 8 Inspect Lift Tite latch rollers for wear or damage positive securement and proper operation 2 Inspect bridge plate for Wear or damage Pr...

Страница 38: ...if needed Tighten or replace if needed Replace damaged parts and resecure as needed Apply Light Grease during reassembly procedures Replace if needed Tighten replace or correct as needed Inspect cotte...

Страница 39: ...rication Schedule Apply Door Ease or replace if needed See Lubrication Diagram Resecure or replace if needed Resecure repair or replace if needed Check to see that the lift is securely anchored to the...

Страница 40: ...nery Directive We hereby certify that the machinery described above conforms with the essential health and safety requirements of Council Directive 2006 42 EC on the approximation of the laws of the M...

Страница 41: ...e human body Safety of machinery Guards General requirements for the design and construction of fixed and moveable parts Safety of machinery Prevention of unexpected start up Safety of machinery Safet...

Страница 42: ...s The figures quoted are emission levels and are not necessarily safe working levels While there is a correlation between the emission and exposure levels this cannot be used reliably to determine whe...

Страница 43: ...LTD Unit 1 Windsor Industrial Estate Rupert Street Aston Birmingham B7 4PR UK Phone 44 0 121 33 35 170 E mail contact autoadapt co uk Dual Parallel Arm Hydraulic Lift System Century 2 Millennium 2 Vi...

Страница 44: ...Page 42...

Страница 45: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Страница 46: ...ax 1 574 946 4670 All illustrations descriptions and specifications in this manual are based on the latest product information available at the time of publication The Braun Corporation reserves the r...