Braun FF3248Y-24V Скачать руководство пользователя страница 12

Page 10

WARNING

Provide adequate 
clearance outside 
of vehicle to ac-
commodate ramp.  
Failure to do so may 
result in serious 
bodily injury and/or 
property damage.

  Ramp Power Operation

  

The power ramp is attendant operated and activated 
by the control switch provided by the vehicle con-
verter (ramp installer).  A momentary contact ramp 
control switch (center off) will typically be provided 
near the driver.  The control switch may be part of a 
panel providing other features and controls (power 
on/off indicators, LED’s, etc.).  

Be certain there is 
adequate clearance 
outside the vehicle 
before deploying 
the power ramp.

The ramp operator 
(attendant) and by-
standers must keep 
clear of the area 
in which the ramp 
operates and clear 
of all moving parts.  

Attendants must ensure that passengers keep clear 
of the area in which the ramp operates.  Do not

 

attempt to grip or hold the ramp or ramp drive arm 
assemblies.

If you are an attendant operating the ramp, it is your 
responsibility to oversee and/or assist in performing 
safe passenger loading and unloading procedures.  
Observe your passengers at all times when they are 
entering and exiting the vehicle.  Attendants must 

be aware of any special needs and/or procedures 
required for safe transport of wheelchair passengers.

Do not attempt to load or unload a passenger in a 
wheelchair or other apparatus that does not 

fi

t on 

the ramp.  Do not exceed the load capacity of the 
ramp.  Passengers should enter and exit one at a 
time.  The attendant should not board the ramp with 
the passenger except when assistance is required 
and the load capacity is not exceeded.  Always 
return the ramp to the stowed position when not in 
use.

CAUTION

Allow ramp to deploy 
fully before boarding.  
Failure to do so may 
result in damage.

Deploy

 Gravity Down Drift:

When deploying (unfolding) the ramp, the ramp 
pump motor stops running when the ramp reaches 
an approximate 45° angle (shut off point).  The 
ramp continues to slowly lower the remaining dis-
tance by the force of gravity (non-powered).

Allow the ramp to unfold (deploy) fully before 
boarding the ramp.  Forcing the ramp out or down 
during the deploy (unfold) function, or boarding 
onto the ramp before it is fully-deployed 

may re-

sult in damage

 to the ramp and/or drive assembly. 

Stow

 Gravity Down Drift:

When stowing the ramp and it reaches an approxi-
mate 45° angle (shut off point), gravity lowers the 
ramp to the pan (

fl

oor).  

Before operating the ramp

, park the vehicle on 

a level area, away from vehicular traf

fi

c.  Place 

the vehicle transmission in “Park” and engage the 
parking brake.  Meet all other interlock conditions 
(as equipped).  Activate the vehicle “kneel” system 
to lower the vehicle (if so equipped).  Lowering the 
vehicle reduces the slope of the ramp.

RAMP OPERATION 

  Power Ramp Safety

WARNING

Keep clear of 
area in which 
ramp operates.

  Gravity Down Drift

Note:

  Pump 

motor shut 
off points are 
microswitch 
adjustable.

Содержание FF3248Y-24V

Страница 1: ...anual before operating installing or servicing ramp Failure to do so may result in serious bodily injury and or property damage Braun RA400 Transit Ramp Model FF3248Y 24V Commercial Braun RA400 Transi...

Страница 2: ...l includes operating instructions installation instructions servicing instructions and instructions for troubleshooting if needed Braun ramps are built for dependability and will provide years of serv...

Страница 3: ...Safety Safety Symbols 13 Ramp Operation Safety Precautions 13 14 Installation Instructions Installation Requirements 14 Chassis Requirements 14 Door Opening 14 Obstructions 15 Installation Illustratio...

Страница 4: ...ns on page 3 for identification of components and clarifica tion of direction terminology As viewed from outside the vehicle Left Right Out In Ramp Terminology Illustration FF3248Y 24V Vertical Side P...

Страница 5: ...ernal components RAMP TERMINOLOGY Ramp Component Terminology Illustrations FF3248Y 24V Cylinder As viewed from outside the vehicle Out In Right Left Pan Weldment Pump Ramp Drive Arm Relays Pump Cylind...

Страница 6: ...unctions powering dual acting hydraulic cylinders No sensitive electronic controls or sensors are required for operation All RA400 ramp models feature gravity down drift during the deploy cycle When d...

Страница 7: ...ssembly Ramp Actions and Functions Deploy Deploy is the action of the ramp assembly raising and unfolding rotating to ground level when the DEPLOY OUT switch is activated installer supplied Stow Stow...

Страница 8: ...tion Keep operator and bystanders clear of area in which the ramp operates Load and unload clear of vehicular traffic Open ramp door s fully and secure before operating ramp Do not overload or abuse R...

Страница 9: ...hair wheels pull wheelie when on the ramp The wheelchair must be positioned in the center of the ramp when loading and unloading Keep ramp owner s manual in ramp mounted vehicle at all times Maintenan...

Страница 10: ...ety information is included It is the responsibil ity of the attendant to properly open and close the ramp access door s to activate interlock s to properly activate the ramp power functions as well a...

Страница 11: ...transit agency s daily service program Simple inspections can detect potential operational problems Keeping the ramp assembly and housing area clean is one of the most effective preventive mainte nan...

Страница 12: ...atus that does not fit on the ramp Do not exceed the load capacity of the ramp Passengers should enter and exit one at a time The attendant should not board the ramp with the passenger except when ass...

Страница 13: ...fessional and wheelchair representative Those procedures should be con veyed to the ramp attendant Know your passen gers abilities and needs for optimum safety Attendants must never operate the vehicl...

Страница 14: ...fect on the center of gravity The wheelchair passenger s center of gravity and their ability to maintain stability and balance must be kept in mind by the wheelchair passenger and the attendant The ai...

Страница 15: ...ecautions RAMP INSTALLATION Safety Symbols SAFETY FIRST Know That C CAUTION This symbol indicates important informa tion regarding how to avoid a hazard ous situation that could result in minor person...

Страница 16: ...be must be positioned under the outboard edge of the opening minimum 1 1 2 x 2 steel tube See Figure B Kneeling Vehicles This dimen sion measured with suspension lowered ADA Installations with the sup...

Страница 17: ...f door Minimum Clear Door Opening Dimensions are defined as fin ished door opening including any intrusive door jambs headers sills or hinges Obstructions Any intrusive ob structions within the door o...

Страница 18: ...TUBE 46 5 34 Figure C Clear Door Opening Width Dimension Chassis Chassis C L C L MinimumDoorOpeningWidth 34 MINIMUM DOOR OPENING WIDTH Figure D Vehicle chassis floor pocket configuration must be alig...

Страница 19: ...F Stowed RA400 Ramp positioned in the floor pocket There must be a minimum 1 8 clearance between the deployed ramp assembly and the vehicle floor or any obstruction on the floor such as a rubber sill...

Страница 20: ...a ramp IN signal must be terminated in the sup plied Deutsch connector The ramp installer provides an appropriate control switch for the end user A momentary contact ramp control switch center off wi...

Страница 21: ...USED PLUG NOT USED H G F E Figure H RAMP INSTALLATION Positive battery lead wire must be protected by installer provided 25 ampere fuse or circuit breaker Failure to do so may result in serious bodily...

Страница 22: ...equivalent Penetrating Oil Aerosol Can Stainless Stick Door Ease 1 68 oz Style tube Stick tube Ramp Hinge LO Gears and Gear Racks 2 Places Internal DE See the Maintenance Lubrication Schedule for reco...

Страница 23: ...ps that are not monitored by Maintenance and lu brication procedures must be performed as specified by an authorized service technician Failure to do so may result in serious bodily injury and or prop...

Страница 24: ...observe drift speed during deploy and stow functions Inspect ramp for wear damage or any abnor mal condition Remove sub floor pan cover and clean dirt and other foreign debris Remove sub floor pan cov...

Страница 25: ...s fittings seals etc for leaks if fluid level is low Inspect vehicle to ramp wiring harness Mounting Decals and Antiskid Use Braun 32840 QT Exxon Univis HVI 26 hydraulic fluid do not mix with Dextron...

Страница 26: ...corresponding parts list is also provided Correct the problem if possible If the problem continues contact The Braun Corporation 1 20 Power to Ramp But No Pump Operation 1 00 NO OPERATION FUNCTION SYM...

Страница 27: ...t replace pump Adjust Drift Cam Contact Braun Product Support replace pump Adjust Drift Cam 2 11 See 1 00 2 12 Drift Out Microswitch out of adjust ment or damaged 2 13 Drift Out Microswitch harness di...

Страница 28: ...to contamination or other wise damaged 4 51 See 2 40 4 61 See 2 40 and 2 52 4 62 Drift In Cam needs adjustment 4 71 See 2 35 2 36 2 62 and 4 62 Adjust or replace Connect repair or replace Activate Dep...

Страница 29: ...Page 27 BLANK for LAYOUT...

Страница 30: ...RCUIT PROTECTION DEVICE 25 AMP GROUND BATTERY RA400 TRANSIT RAMP ASSEMBLY POWER CONNECTIONS CONTROL SIGNALS PROVIDED BY INSTALLER SYMBOL KEY DRIFT OUT MICROSWITCH DEPLOY RELAY COUNTER 14 GA BL BK 12 G...

Страница 31: ...CLE GROUND 12 GA POWER SOURCE 12 GA TO DEPLOY INDICATOR 14 GA TO STOW INDICATOR 14 GA PLUG NOT USED PLUG NOT USED 87 87a 30 85 86 4 3 2 1 COLOR LOC COUNTER WIRE CODE COUNTER 87 87a 30 85 86 COM N O N...

Страница 32: ...ectional Displacement Pump Motor Bidirectional Flow Control Valve Fixed Orifice 3 Way 2 Position Shuttle Valve M Description Symbol Reservoir Vented Relief Valve Check Valve Hydraulic Port Filter Scre...

Страница 33: ...8 DIA SW SW 16004A 005 5 5 1 HOSE ASSEMBLY 9 1 8 DIA SW SW 16004A 009 6 1 HOSE ASSEMBLY 26 1 8 DIA SW SW 16004A 026 7 1 HOSE ASSEMBLY 30 1 8 DIA SW SW 16004A 030 8 4 ELBOW 7 16 20 M O RING 45 24505 9...

Страница 34: ...E ASSEMBLY 5 5 1 8 DIA SW SW See Hyraulics 16004A 005 5 32 1 HOSE ASSEMBLY 9 1 8 DIA SW SW See Hyraulics 16004A 009 33 1 HOSE ASSEMBLY 30 1 8 DIA SW SW See Hyraulics 16004A 030 34 1 HOSE ASSEMBLY 26 1...

Страница 35: ...EXPLODED VIEW 30 16 23 21 22 23 21 19 12 24 47 30 11 49 13 23 21 22 6 57 58 20 5 2 3 48 48 49 14 8 49 30 15 48 30 30 9 20 26 40 49 35 45 49 18 20 2 48 3 49 7 14 49 49 13 4 20 58 57 22 20 22 21 23 1 6...

Страница 36: ...Stowed View Deployed View Power Unit Hydraulic Pump Module Voltage 24 VDC Notes Mounting holes brackets per application 2 25 48 325 2 485 22 281 23 597 2 62 31 994 33 50 32 500 49 318 48 325 35 500 9...

Страница 37: ...to anyone Braun reserves the right to make changes in the design or material of its products without incurring any obligation to incorporate such changes in any previously manufactured product Braun m...

Страница 38: ...another entity Note the written warranty provided by the manufacturer of the material component or part is the direct responsibility of that manufacturer items that are added or changed after the prod...

Страница 39: ...s do not allow a reduction in the statute of limitations so this reduction may not apply to you WARRANTY REGISTRATION and MISCELLANEOUS Your warranty registration records should be completed and deliv...

Страница 40: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Страница 41: ...re based on the latest product information available at the time of publication The Braun Corporation reserves the right to make changes at any time without notice 35168 November 2008 35168 November 2...

Отзывы: