Tipo: 

Termómetro Infrarrojo de Frente BFH175US 

Rango de Medición: 

34°-43°C (93.2°-109.4°F) 

Resolución:  

0.1 °C ó °F  

Precisión (Laboratorio):  

0.2 °C para el rango 35 °C – 42 °C 

 

(0.4 °F para 95 °F – 107.6 °F ) 

 

fuera de ese rango ± 0.3°C/0.5°F 

 

(Temperatura Ambiente: 15 °C a 40 °C  (59 °F a 104 °F) 

 

Este termómetro muestra una estimación 

 

equivalente oral calculada.  

Pantalla:  

Pantalla de Cristal Líquido, 4 dígitos más íconos especiales 

Acústica: Audio: 

 

 

 Rango de temp normal=1 pitido largo de 0.4 segundos de 
duración

 

Fiebre=10 pitidos cortos de 0.2 segundos de duración

Temperatura de Operación: 

15°C- 40°C (59°F- 104°F)  

Apagado Automático: 

Aprox. 30 segundos después de haber tomado la última medición 

Peso:  

3.32 oz. (con pilas), 2.52 (sin pilas)

Rangos de almacenamiento a largo plazo 
Temperatura de almacenaje/transporte: 

–25 °C a 55 °C (–13 °F a 131 °F) 

Humedad: 

15–95% sin condensación 

Pilas:   

(2) Pilas AAA - al menos 500 mediciones 

Presión: 70kPa-106kPa(0.7atm-1.06atm)
Este termómetro es un termómetro de modo ajustado que proporciona una lectura equivalente oral.
Este termómetro infrarrojo cumple con los requisitos establecidos en el Estándar ASTM E 1965-98 (para el 
sistema del termómetro). Completa responsabilidad por la conformidad del producto con el estándar es 
asumida por Kaz USA, Inc., una Empresa de Helen of Troy, Health & Home, 400 Donald Lynch Blvd., Suite 300, 
Marlborough, MA 01752
Los requisitos de precisión de laboratorio ASTM, para el termómetro sólo en el rango de pantalla de 36 °C a 
39°C  (96.8 °F a 102.2 °F) para termómetros infrarrojos es ±0.3 °C (±0.5 °F), mientras que para los termómetros 
de mercurio en vidrio y electrónicos , el requisito para los Estándares ASTM E 667-86 y E 1112-86 es ±0.1 °C 
(±0.2 °F).
Este dispositivo cumple con los siguientes estándares:
EN 60601-1:2014 Equipo médico eléctrico. Requisitos generales de seguridad básica y funcionamiento esencial. 
ISO 80601-2-56:2017 Requisitos particulares para la seguridad básica y funcionamiento esencial de 
termómetros clínicos para medición de temperatura corporal. 
ASTM E1965-98:2016 - Especificación Estándar para Termómetros Infrarrojos para Determinación Intermitente 
de la Temperatura del Paciente.
IEC 60601-1-2:2014: Equipo médico eléctrico – Parte 1-2: Requisitos generales de seguridad básica y 
desempeño esencial - Estándar Colateral: Compatibilidad Electromagnética - Requisitos y pruebas.
NOTA: 

NO utilice este dispositivo en presencia de interferencias electromagnéticas u otras fuera del rango 

normal especificado en IEC 60601-1-2.
ISO 15223-1:2016: Símbolos para uso en etiquetado de dispositivos médicos.
EN 1041: 2008 Información suministrada por el fabricante de los dispositivos médicos.
IEC 60601-1-11:2015  Equipo médico eléctrico – Parte 1-11: Requisitos generales de seguridad básica y 
desempeño esencial – Estándar colateral: Requisitos para los equipos médicos eléctricos y sistemas  

médicos eléctricos utilizados en el entorno familiar de atención médica.

Especificaciones del producto

Содержание BFH175

Страница 1: ...Forehead Thermometer BFH175...

Страница 2: ...d Suite 300 Marlborough MA 01752 Cont ctenos Preguntas o Comentarios Ll menos lada gratuita al 1 800 327 7226 Correo Electr nico consumerrelations kaz com Visite www braunthermometers com Por favor as...

Страница 3: ...1 English 5 6 4 1 Protective scanner cap 2 Scanner 3 Battery door 4 LCD screen 5 Temperature button 6 Power button 1 2 3...

Страница 4: ...pen surface on the thermometer This thermometer consists of high quality precision parts DO NOT drop the instrument Protect it from severe impact and shock DO NOT twist the instrument or the measuring...

Страница 5: ...This thermometer is not intended for pre term babies or small for gestational age babies Pre term is defined as babies with a calendar age of less than 37 weeks Small for gestational age is defined a...

Страница 6: ...onds when the unit is switched ON How the Braun Forehead thermometer works The Forehead thermometer measures infrared energy radiated from the skin and surrounding tissue on the center of the forehead...

Страница 7: ...ure with a standard digital thermometer for confirmation This thermometer displays an oral equivalent temperature reading Oral readings are approximately 0 9 F 0 5 C lower than a rectal digital measur...

Страница 8: ...arized himself herself with the instrument and obtains consistent readings General precautions Remove any sweat prior to measuring with a dry cloth Avoid any cooling or warming cloths on the forehead...

Страница 9: ...of the forehead just above and between the eyebrows Be sure to hold the thermometer flush against the forehead It is important to hold the thermometer and the forehead steady during measurement Movem...

Страница 10: ...hear a long beep indicating normal temperature range or 10 short beeps indicating fever Read temperature At the confirmation beep remove the thermometer from the forehead and read the temperature The...

Страница 11: ...ayed for 2 seconds when it is turned on Changing the temperature scale 2 3 4 Open battery compartment and remove the batteries C F switch is found in the center of the battery compartment Slide switch...

Страница 12: ...the interior of the thermometer NEVER use abrasive cleaning agents thinners or benzene for cleaning and NEVER immerse the thermometer in water or other cleaning liquids Replacing the batteries The Fo...

Страница 13: ...em error self check display flashes continuously and will not be followed by the ready beep and the ready symbol If error persists If error still persists Error message Solution When you receive this...

Страница 14: ...lied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdi...

Страница 15: ...MA 01752 ASTM laboratory accuracy requirements for the thermometer only in the display range of 96 8 F to 102 2 F 36 C to 39 C for infrared thermometers is 0 5 F 0 3 C whereas for mercury in glass and...

Страница 16: ...For detailed description of EMC requirements please contact Consumer Relations Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT Remove the battery from the instr...

Страница 17: ...15 English...

Страница 18: ...16...

Страница 19: ...17 Espa ol 1 Tapa protectora del esc ner 2 Esc ner 3 Puerta de las pilas 4 Pantalla LCD 5 Bot n de temperatura 6 Bot n de encendido 5 6 4 1 2 3...

Страница 20: ...a sido dise ado Por favor siga las precauciones generales de seguridad cuando lo utilice en los ni os NUNCA sumerja el term metro en agua u otros l quidos no es a prueba de agua Para limpieza y desinf...

Страница 21: ...mal Este term metro no est dise ado para beb s prematuros o peque os para la edad gestacional Se define como beb prematuro a los beb s con una edad de calendario de menos de 37 semanas Se define como...

Страница 22: ...mente durante 2 segundos cuando la unidad est ENCENDIDA C mo funciona el term metro de Frente Braun El term metro de Frente mide la energ a infrarroja irradiada por la piel y del tejido circundante en...

Страница 23: ...la nica manera de diagnosticar con precisi n la fiebre Tome varias lecturas cuando est sano para determinar la temperatura normal Vuelva a medir con un term metro digital est ndar para confirmar Este...

Страница 24: ...cia o ausencia de fiebre es cr tica Cuando el usuario est aprendiendo a usar el term metro por primera vez hasta que se familiarice con el instrumento y obtenga lecturas consistentes Precauciones gene...

Страница 25: ...sici n Coloque el term metro en el centro de la frente justo por encima y entre las cejas Aseg rese de mantener el term metro al ras contra la frente Es importante mantener el term metro y la frente e...

Страница 26: ...un rango de temperatura normal o 10 pitidos cortos que indiquen fiebre Leer la temperatura Con el pitido de confirmaci n retire el term metro de la frente y lea la temperatura La pantalla iluminar el...

Страница 27: ...uando se encienda Cambiar la escala de la temperatura 2 3 4 Abra el compartimiento de las pilas y ret relas El interruptor C F se encuentra en el centro del compartimiento de las pilas Deslice el inte...

Страница 28: ...o y limpieza Para evitar rayar la superficie del esc ner vuelva a colocar la tapa protectora despu s de cada uso El term metro debe limpiarse entre usos Utilice una gasa con alcohol o un hisopo de alg...

Страница 29: ...ntos parpadean La visualizaci n de error de sistema autocomprobaci n parpadea continuamente y no va seguido del pitido de listo y del s mbolo de listo Si el error persiste Si a n persiste el error Men...

Страница 30: ...posible que estas limitaciones o exclusiones no se apliquen en su caso Esta garant a le confiere ciertos derechos legales espec ficos Es posible que usted tambi n tenga otros derechos legales los que...

Страница 31: ...recisi n de laboratorio ASTM para el term metro s lo en el rango de pantalla de 36 C a 39 C 96 8 F a 102 2 F para term metros infrarrojos es 0 3 C 0 5 F mientras que para los term metros de mercurio e...

Страница 32: ...das con EMC Para la descripci n detallada de los requisitos EMC por favor contacte Servicio al Cliente Los equipos de comunicaci n RF port til y m vil pueden afectar a los EQUIPOS M DICOS EL CTRICOS R...

Страница 33: ...31 Espa ol...

Страница 34: ...n de pulsos Modulaci n de pulsos Modulaci n de pulsos LTE Banda 7 LTE Banda 5 LTE Banda 13 17 LTE Banda 1 3 Modulaci n de pulsos Para algunos servicios s lo se incluyen las frecuencias de subida La po...

Страница 35: ......

Страница 36: ......

Страница 37: ...text Revision 1 Release Date Date 03OCT18 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Coating Overall Gloss Varnish Spot UV Magenta 0 Yellow 0 Black 100 PMS GOE...

Отзывы: