BRASS Akron Style 3414 Apollo Скачать руководство пользователя страница 3

3

A.  STYLES 3414 APOLLO S.I. 
When used in the portable base, the unit should not be operated at more than 600 GPM. Therefore, do not exceed the following 
discharge pressures with straight tips unless the unit is secured in the direct connect flange base:

Also, do not exceed 1000 GPM (3800 LPM) when using a fog nozzle, unless the unit is secured in the direct connect flange base.
Be sure the storz or swivel is attached securely.
For Use with 4”, 4-

1

/

2

” or 5” hose only.

Setup Instructions:
The following hose set-up must be used to provide necessary stability when operating the Style 3414.  (See Figure 2)
Aim center leg toward target.  Slide buckles to end of tie-down straps. Connect straps loosely around hose. 
DO NOT tighten.
Set spikes with hammer.
Ensure lock pins are fully engaged.
Aim discharge upward.
Secure safety chain.
Charge hose slowly.
Tighten straps around hose until it contacts hose stop.
If unit moves while charging, reset spikes.
When the unit is operating in the portable base, do not attempt to move or pickup any part of the base itself, the hose loop, or 
the 10 feet (3m) of straight hose ahead of the hose loop.
When the unit is stored in the direct base or truck mount, it is recommended that the nozzle or tips be lowered against a rigid 
support or removed during transportation.

TIp SIZE  

pSI      

kpa

1 1/4” 

80      

550

1 1/2”  

80       

550

Содержание Akron Style 3414 Apollo

Страница 1: ...iping causing injury to the operator or others WARNING A 1 4 turn shut off valve should not be used with the Apollo If any other type of shut off valve is used it must be opened and closed slowly Opening and closing a valve too quickly may result in damage to the Apollo and other equipment which can result in an injury to the operator or others WARNING Read and follow the Safety Chain Warning Tag ...

Страница 2: ...und spike with a sharp blow from a hammer or another tool sufficient to drive the spike at least 1 8 3mm into the concrete This process must be repeated each time the unit is repositioned on a concrete surface As with any portable monitor the Apollo should always be secured with the safety chain or ropes before using on any surface CAUTION Wear safety glasses or face shield when setting the spikes...

Страница 3: ...ing the Style 3414 See Figure 2 Aim center leg toward target Slide buckles to end of tie down straps Connect straps loosely around hose DO NOT tighten Set spikes with hammer Ensure lock pins are fully engaged Aim discharge upward Secure safety chain Charge hose slowly Tighten straps around hose until it contacts hose stop If unit moves while charging reset spikes When the unit is operating in the ...

Страница 4: ... legs using a non slip knot 3 Tie the other end of each rope to an immovable object at no more than a 45 angle from the center front leg using a non slip knot 4 The standard Apollo SI safety chain must also be attached to an immovable object as a backup 5 Once set up the monitor and hose should be pulled backwards to take some of the slack out of the ropes Movement will occur at elevations below 3...

Страница 5: ...d Apollo SI operating instructions for other standard operating requirements before use ROUTINE MAINTENANCE INSTRUCTIONS Style 3414 Apollo Portable Monitor The following maintenance procedures will extend the service life of this appliance A Four grease fittings are provided for lubrication Use Low Temp Lubriplate or equivalent 1 The horizontal and vertical swivel joints should be lubricated until...