3  SERVICE MODE – ADJUSTING THE OPERATION PARAMETERS

By switching on the dispenser using the master switch and holding down key A simultaneously, the machine can be started up in 
service mode and make adjusting the Operation Parameters. The dispenser will function normally, but it will be possible to modify 
the operation parameters and any modifications carried out will be stored in the memory for the next time the dispenser is switched 
on in normal mode.
When the machine is in use, to adjust the operation parameters, hold down keys C and D simultaneously. The display will show the 
code PA01 to indicate the first parameter which may be modified. Pressing keys C and D enables the selection of the parameter to 
be modified. Pressing key A will then make it possible to activate the modification of the chosen parameter. The display will show 
the current value of the parameter. This value can be modified using keys C and D. Pressing key A once more or waiting three se-
conds without pressing any keys confirms the new value and the display will return to the list of parameters. To exit the parameter 
adjustment, hold down keys C and D simultaneously or do not press any key for three seconds.

LIST OF PRODUCTION PARAMETERS B-CREAM 1/2/3

LIST OF PRODUCTION PARAMETERS B-CREAM HD 1/2/3

Test Mode

In this mode, the machine does not function and it is possi-

ble to manually activate individual components to check

that they are functioning correctly.

Master key E

Production Test Mode

In this mode, the machine does not function and it is possi-

ble to activate individual components in sequence to check

that they are functioning correctly.

Master key H

IMPORTANT

On dispensers with more than one tank, the operating parameters, from PA01 to

PA10, must be set separately for each tank.

NAME

DESCRIPTION

ADJUSTMENT INTERVAL

DEFAULT VALUE

PA01

Minimum temperature in Ice Cream Production Mode: This is the

minimum possible temperature of the product when the density is

adjusted to a value of 10.

0...-18 °C

-14

PA02

Maximum density in Ice Cream Production Mode: this is the ab-

sorption value of the motor corresponding to the adjustment of the

density to a value of 10.

0...100 W

60

PA03

Motor rotation speed in Ice Cream Production Mode with an unfi-

nished product.

500…6000 giri/min

3500

PA04

Motor rotation speed in Ice Cream Production Mode with a finished

product.

500…6000 giri/min

3500

PA05

Motor rotation speed in Conservation Mode.

500…6000 giri/min

1000

PA06

Temperature produced in Conservation Mode.

- 25 ÷ + 10 °C

2 °C

PA07

Lock Keypad.

0 / 1 / 2

0

PA08

Scale representation of temperature.

C…F

C

PA09

Firmware version display circuit board.

Visualisation only

PA10

Firmware version power circuit board.

Visualisation only

NAME

DESCRIPTION

ADJUSTMENT INTERVAL

DEFAULT VALUE

PA01

Minimum temperature in Ice Cream Production Mode: This is the

minimum possible temperature of the product when the density is

adjusted to a value of 10.

0...-18 °C

-14

PA02

Maximum density in Ice Cream Production Mode: this is the ab-

sorption value of the motor corresponding to the adjustment of the

density to a value of 10.

45...90 W

75

PA03

Motor rotation speed in Ice Cream Production Mode with an unfi-

nished product.

2000…6000 giri/min

4000

PA04

Motor rotation speed in Ice Cream Production Mode with a finished

product.

2000…6000 giri/min

2000

PA05

Motor rotation speed in Conservation Mode.

1000…6000 giri/min

1000

PA06

Temperature produced in Conservation Mode.

- 5 ÷ + 10 °C

2 °C

Содержание B-cream HD 1

Страница 1: ...d 16 and the power supply transformer 15 for both the circuit boards and the geared motor to drive the mixers The upper half of the dispenser contains the transparent tank 8 designed for the food prod...

Страница 2: ...ned off If you press it for two seconds the dispenser switches to Cleaning mode the mixer is on but the cooling is off F Conservation indicator light flashing light product conservation mode selected...

Страница 3: ...selected product ready H Ice cream production key allows you to select the ice cream production operating mode On dispensers with more than one tank if you hold this key down while the tank is in ice...

Страница 4: ...torage mode PA05 parameter As well as the operating modes described in the Instruction Manual the dispenser may be started up in other modes which can be used for technical support These modes are sum...

Страница 5: ...functioning correctly Master switch key H IMPORTANT On dispensers with more than one tank the operating parameters from PA01 to PA10 must be set separately for each tank NAME DESCRIPTION ADJUSTMENT IN...

Страница 6: ...in more containers from the factory parameters PA11 to PA 27 are common to all the distributor and therefore can only be adjusted by the control panel on the right container NAME DESCRIPTION ADJUSTME...

Страница 7: ...w to verify is the efficiency of the cooling system which can be reduced for example due to a leak of refrigerant gas In order to execute such a check a test with product 90 minutes long is required 7...

Страница 8: ...is operating in Service Mode Service Mode or Super AL09 Error Hall probes This alarm stops the operation of the machine AL10 Lack of communication between master and slave card 1 This alarm stops the...

Страница 9: ...r filter 2 Loosen the fastening screws and remove the side panels 3 Loosen the screws and remove the front panel Then remove the condensation water drain cover 4 Once you have removed the cover the ta...

Страница 10: ...he rear of the board Loosen all the housing securing screws and then remove the board itself 3 To remove the power board you need to disconnect all the connectors then pull down the two side anchor ta...

Страница 11: ...EFROSTING FAN AND THE LID PRESENCE SENSORS 1 Remove the air conveyor by pressing on either side Pull the defrosting fan out of its seat in the conveyor The lid presence detectors are situated at the r...

Страница 12: ...To update the control board firmware perform the steps described below 1 Collect the programmer to the USB port on the PC where the firmware update files are stored The programmer will be recognised b...

Страница 13: ...GRAMMING light will flash for a few seconds and when it remains permanently lit programming has been terminated correctly 4 Switch off the master switch and disconnect the machine from the mains 5 Dis...

Страница 14: ...ure 4 Referring to figure 3 proceed as follows 1 Begin the inspection at the High Pressure zone discharge of the compressor Check around the seals 2 Follow the copper pipes to the condenser and check...

Страница 15: ...illing unit on the pressure gauge to the charging unit 2 Connect the VAC filling unit to the vacuum pump and open the VAC valve 3 Open the valve on the charging unit and for a moment also open the REF...

Страница 16: ...re covered with frost 9 Close the LOW valve disconnect the LOW pipe from the compressor charging pipe and screw the cap onto the bottom of the charging pipe As an indication the temperatures and corre...

Страница 17: ...ply circuit board 2 Transformer 9 Display circuit board 3 Electrovalve 10 Temperature probe 4 Compressor 11 Reed safety switches 5 Fan 13 LED board hat optional 6 Geared motor 14 LED Board cop shoulde...

Страница 18: ...board 2 Transformer 10 Temperature probe 3 Electrovalve 11 Reed safety switches 4 Compressor 13 LED board hat optional 5 Fan 14 LED Board cop shoulder optional 6 Geared motor 15 LED Strip cop shoulder...

Страница 19: ...DIAGRAM POWER SUPPLY DISPLAY MINIGEL 17 TOPOGRAFIC DIAGRAM POWER SUPPLY DISPLAY MINIGEL PLUS KEY M1 Temperature probe M2 MASTER board M3 Faucet Reed switch opt KEY M1 Temperature probe M2 MASTER board...

Страница 20: ...ost fan M4 Solenoid valve M12 Earthing M5 Compressor M13 Slave 1 board M6 Display board M14 Slave 2 board M7 Not connected M15 Closed machine without solenoid valve M8 Top cover LED board M16 Open mac...

Страница 21: ...49 20 TOP COVER LED TOPOGRAPHY 21 REAR COVER LED TOPOGRAPHY KEY M1 Motherboard M2 LED strip power supply board KEY M1 LED power supply board M2 Rear cover LED strip...

Страница 22: ...e density adjustment will be auto matically reduced by one unit Hold down the H key for two seconds to cle ar the alarm message The machine does not start up Message AL04 is indicated on the display T...

Страница 23: ...ine to the power supply Message AL13 shown on the display System clock out of order The machine can work but the defrost timer can t be used Replace display pcb Message AL14 shown on the display Batte...

Страница 24: ...otor is not functioning short circuit or mechanical blockage Replace the compressor see chapter 10 Electrovalve is not opening coil Replace electrovalve coil Electrovalve is not opening body Replace e...