3 SERVICE MODE – ADJUSTING THE OPERATION PARAMETERS
By switching on the dispenser using the master switch and holding down key A simultaneously, the machine can be started up in
service mode and make adjusting the Operation Parameters. The dispenser will function normally, but it will be possible to modify
the operation parameters and any modifications carried out will be stored in the memory for the next time the dispenser is switched
on in normal mode.
When the machine is in use, to adjust the operation parameters, hold down keys C and D simultaneously. The display will show the
code PA01 to indicate the first parameter which may be modified. Pressing keys C and D enables the selection of the parameter to
be modified. Pressing key A will then make it possible to activate the modification of the chosen parameter. The display will show
the current value of the parameter. This value can be modified using keys C and D. Pressing key A once more or waiting three se-
conds without pressing any keys confirms the new value and the display will return to the list of parameters. To exit the parameter
adjustment, hold down keys C and D simultaneously or do not press any key for three seconds.
LIST OF PRODUCTION PARAMETERS B-CREAM 1/2/3
LIST OF PRODUCTION PARAMETERS B-CREAM HD 1/2/3
Test Mode
In this mode, the machine does not function and it is possi-
ble to manually activate individual components to check
that they are functioning correctly.
Master key E
Production Test Mode
In this mode, the machine does not function and it is possi-
ble to activate individual components in sequence to check
that they are functioning correctly.
Master key H
IMPORTANT
On dispensers with more than one tank, the operating parameters, from PA01 to
PA10, must be set separately for each tank.
NAME
DESCRIPTION
ADJUSTMENT INTERVAL
DEFAULT VALUE
PA01
Minimum temperature in Ice Cream Production Mode: This is the
minimum possible temperature of the product when the density is
adjusted to a value of 10.
0...-18 °C
-14
PA02
Maximum density in Ice Cream Production Mode: this is the ab-
sorption value of the motor corresponding to the adjustment of the
density to a value of 10.
0...100 W
60
PA03
Motor rotation speed in Ice Cream Production Mode with an unfi-
nished product.
500…6000 giri/min
3500
PA04
Motor rotation speed in Ice Cream Production Mode with a finished
product.
500…6000 giri/min
3500
PA05
Motor rotation speed in Conservation Mode.
500…6000 giri/min
1000
PA06
Temperature produced in Conservation Mode.
- 25 ÷ + 10 °C
2 °C
PA07
Lock Keypad.
0 / 1 / 2
0
PA08
Scale representation of temperature.
C…F
C
PA09
Firmware version display circuit board.
Visualisation only
PA10
Firmware version power circuit board.
Visualisation only
NAME
DESCRIPTION
ADJUSTMENT INTERVAL
DEFAULT VALUE
PA01
Minimum temperature in Ice Cream Production Mode: This is the
minimum possible temperature of the product when the density is
adjusted to a value of 10.
0...-18 °C
-14
PA02
Maximum density in Ice Cream Production Mode: this is the ab-
sorption value of the motor corresponding to the adjustment of the
density to a value of 10.
45...90 W
75
PA03
Motor rotation speed in Ice Cream Production Mode with an unfi-
nished product.
2000…6000 giri/min
4000
PA04
Motor rotation speed in Ice Cream Production Mode with a finished
product.
2000…6000 giri/min
2000
PA05
Motor rotation speed in Conservation Mode.
1000…6000 giri/min
1000
PA06
Temperature produced in Conservation Mode.
- 5 ÷ + 10 °C
2 °C