4.0
Operation
LIGHTING PROCEDURES:
1
Verify that service lid is secured.
2
Open (turn on) gas supply to the heater.
3
Close (turn on) electrical circuit (typically thermostat).
4
If the heater fails to light, turn off gas, open electrical circuit (set thermostat to lowest setting or to off).
Wait five (5) minutes before repeating above steps.
SHUTDOWN PROCEDURES:
1
Open (turn off) electrical circuit.
2
Close (turn off) gas supply to the heater.
3
Wait five (5) minutes before relighting heater.
WARNING
!
BEFORE OPERATING
, smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle to the floor. Refer to the cover page “If you smell gas”
and on safety label affixed to the heater.
Do not
use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas control
which has been under water.
This appliance does not have a pilot ignition. It is equipped with an ignition device which
automatically lights the burner.
Do not
attempt to light the system by hand.
Operating Instructions
WARNING
!
Use only your hand to turn the manual shutoff. Never use tools. If the
knob will not turn by hand, don’t try to repair it; call a qualified technician.
Force or attempted repair may result in a fire or explosion.
4.0
Operation
•
Operating Instructions