100-214-276 Rev. 3
5-1
2000X aed Actuator
Chapter 5: Technical Specifications
Instruction Manual
Technical Specifications
Chapter 5: Technical Specifications
- - - - - - - - - - - - - - - - - - - - - 5-1
Requirement Specifications - - - - - - - - - - - - - - - - - - - 5-1
Performance Specifications - - - - - - - - - - - - - - - - - - - 5-2
- - - - - - - - - - - - - - - - - - - - - - - 5-3
Standard Items - - - - - - - - - - - - - - - - - - - - - - - - - 5-3
5.1 Technical Specifications
5.1.1 Requirement Specifications
The 2000X Actuator requires compressed air. The factory air source must be “clean (5 micron)
and dry,” that is, does not include moisture or lubricants. The Actuator requires 70 psi minimum
pressure for operation and cooling, and can require up to 100 psig maximum, depending on the
application. The following table lists environmental specifications for the ultrasonic welder.
All electrical input power connections are to the Power Supply.
Table 5.1
Environmental Specifications
Environmental Concern
Acceptable Range
Humidity
30% to 95% non-condensing
Ambient Temperature
+5°C to +50°C (+41°F to +122°F)
Storage/Shipping Temperature
-25°C/-13°F to +55°C/+131°F
(+70°C/+158°F for 24 hours)