background image

page  05

SECTION  2

Programming The Operator

To set the auto-close function press 
and hold the 

“SET”

 button until the 

display shows 

“P1”

. Press the 

“UP”

 

button until the display shows 

“P4”

.

When the desired setting is reached 
press the 

“SET”

 button.  The operator 

will return to 

“STANDBY”

 mode to 

indicate that the setup is complete.

5

Setting the Auto-Close Timer
Important Note:- 

The Auto-Close function should not be 
used unless IR Safety Beams are fitted 
to the operator.  Brano Industries 
recommends that the Auto-Close 
function be disabled. Using this function 
is done entirely at the risk of the 
installer and the home owner. Brano 
Industries cannot be held responsible 
for any damage to property and or 
injury to persons.

Press the 

“SET”

 button to enter the 

setup mode and the display will show 
the current setting. Using the 

“UP”

 and 

“DOWN”

 buttons adjust the setting 

until you reach the desired auto-close 
time. 

When the desired time is reached press 
the 

“SET”

 button. The operator will 

return to 

“STANDBY”

 mode to indicate 

that the setting is complete.

7

Switching The  Auto-Close Function 
ON or OFF

The default setting for the Auto-Close 
function is off.  The function must be 
turned on before the operator will close 
the door automatically. To switch the 
auto-close funtion 

“ON”

 or 

“OFF”

 

press and hold the 

“SET”

 button until 

the display shows 

“P1”

. Press the 

“UP”

 button until the display shows 

“P5”

.

The display will show the current 
setting - in the default setting 

“H0”

 the 

IR Safety Beams are disabled. Use the 

“UP”

 and 

“DOWN”

 buttons to switch 

between 

“H0”

 - IR Beams disabled and

               

“H1” 

- IR Beams enabled.

“10”

 seconds is the minimum and 

“90”

 seconds the maximum that the 

timer can be set to.

Press the 

“SET”

 button and the display 

will show the current setting. Press the 

“UP”

 or 

“DOWN”

 button to switch 

between 

“b0”

 - Auto-Close Disabled 

        and 

“b0” 

- Auto-Close Enabled.

When the desired setting is reached 
press the 

“SET”

 button.  The operator 

will return to 

“STANDBY”

 mode to 

indicate that the setup is complete.

Содержание Aladdin II

Страница 1: ...rator Setup Instruction and Users Manual brano industries pty ltd October 2009 COPYRIGHT C Manual AL N01 Version 1 brano industries pty ltd p o box 277 bramley 2018 rep of south africa tel 27 011 887...

Страница 2: ...el 012 349 1494 Fax 012 349 2963 Westrand brano westrand cc Tel 011 760 5773 3884 Fax 011 760 5774 For more information on your nearest agent or distribution center please contact us on our Share Call...

Страница 3: ...Light Time 3 Minutes 1 8 Programming Console Soft Touch Push Button Control Pad with LED Display 1 9 Functions Soft Start and Soft Stop Adjustable Overload Sensitivity Connection Points for Safety Bea...

Страница 4: ...page 02 SECTION 1 Technical Specifications 3 Control Panels Layout 4 Terminals and Connections...

Страница 5: ...ion is reached press the SET button The LED display will change from OP to CL to show that the up limit have been set Using the DOWN button jog the door to the closed position The display will show CL...

Страница 6: ...once and the display will show P2 Press the SET button to enter setup mode The display will show the current setting To increase the sensitivity press the UP button and to decrease the sensitivity pr...

Страница 7: ...esired auto close time When the desired time is reached press the SET button The operator will return to STANDBY mode to indicate that the setting is complete 7 Switching The Auto Close Function ON or...

Страница 8: ...se Timer 10 10 Seconds Shortest Setting 20 20 Seconds 30 30 Seconds 40 40 Seconds 50 50 Seconds 60 60 Seconds 70 70 Seconds 80 80 Seconds 90 90 Seconds Longest Setting 5 P5 Auto Close ON and OFF b0 Au...

Отзывы: