P/N
900000181 REV. A
12
6.2.1
SNMPWALK and OIDs
The top-level Object Identifier (OID) for Brandywine devices is iso.identified-
organization.dod.internet.private.enterprise.brandywine (1.3.6.1.4.1.18954)
The following example shows the command for walking the Brandywine MIBs from
the top of the tree and it’s output.
root@beaglebone:~# snmpwalk -v3 -l authPriv -u dinrailUser -a SHA -A
dinrailAuthPassPhrase -x AES -X dinrailPrivPassPhrase 192.168.1.212
1.3.6.1.4.1.18954
SNMPv2-SMI::enterprises.18954.500.1.1.0 = INTEGER: 6034
SNMPv2-SMI::enterprises.18954.500.1.2.0 = STRING: "001-0509"
SNMPv2-SMI::enterprises.18954.500.1.3.0 = STRING: "0AB34A"
SNMPv2-SMI::enterprises.18954.500.1.4.0 = STRING: "925601301"
SNMPv2-SMI::enterprises.18954.500.1.5.0 = STRING: "v1.0"
SNMPv2-SMI::enterprises.18954.502.6034.1.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.2.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.3.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.4.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.5.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.6.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.7.0 = INTEGER: 0
SNMPv2-SMI::enterprises.18954.502.6034.8.0 = INTEGER: 1
SNMPv2-SMI::enterprises.18954.502.6034.9.0 = INTEGER: 1
SNMPv2-SMI::enterprises.18954.502.6034.10.0 = Gauge32: 143
In this example the DIN Rail is at IP 192.168.1.212.
Содержание RFS-700D
Страница 14: ...P N 900000181 REV A 14 8 Front Panel Drawing...
Страница 15: ...P N 900000181 REV A 15 9 Rear Panel Drawing...
Страница 16: ...P N 900000181 REV A 16 10 Parts Lists...