Setup
Remove the Master Clock System from the shipping carton. The following items
should be included in the shipment:
1x Master Clock System
2x Power supply cables
1x CD-ROM containing User Manual and Utility Software
2.1
Installation
2.1.1
Mounting
The Master Clock System can be installed into a 19” rack mount cabinet using rack
slides. Slides are installed using 10-32 UNF-2B hardware.
Optional Rack Mount Slides:
P/N 002000123, SLIDE, RACK, 24", 21" TRAVEL, 85 LB
P/N 002000150, SLIDE, RACK, 28", 27" TRAVEL, 80 LB
Original Manufacturer: General Devices Chassis Trak Type C300.
2.1.2
Power
Insert the power cord of the Master Clock System into an electrical socket to power
up the unit.
If dual redundant power is required, connect both power sources to independent
power sources
Note that the Master Clock System uses a custom power cable designed to lock in
place. Be sure to only use power cables made by Brandywine Communications
Power Cable Part Number:
2.1.3
Ethernet
Connect one end of an Ethernet patch cable to the Master Clock System Ethernet
located on the Master Clock Module. Connect the other end of the Ethernet cable to
the network with an Ethernet hub or switch.