28
and
65
cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a double poled switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning!
Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
• To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
•
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
• Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
•
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
•
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
• Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Fig. 3-4
Remove the grease filters.
1
With a pencil, make a line on the wall, up to the ceiling,
corresponding to the centre line, it will make the
installation operations easy.
2
Apply the drilling diagram to the wall: the vertical centre
line printed on the drilling diagram shall correspond to the
centre line drawn on the wall. Furthermore, the lower
edge of the drilling diagram corresponds to the lower
edge of the hood.
3
Make the holes indicated on the template, insert the wall
plugs equipped with hooks and adjustment screws.
4
Apply the chimney stirrup to the wall next to the ceiling,
use the stirrup as template (the small notch on the upper
side must correspond to the centre line previously
marked on the wall), mark 2 holes with a pencil. Make the
holes and insert 2 plugs.
5
Fix the chimney support stirrup to the wall by 2 screws.
6
Hang the hood on the hooks and level it using the
adjustment screws placed on the hooks themselves.
7
Mark with a pencil the position for the 4 final fixing screws
T
and
R
.
8
Remove the hood and bore where marked (4 x Ø 8 mm).
9
Insert the wall plugs and 2 screws in the upper holes,
screw in partially, the screws will stand as additional
hooking points.
10
Hook back the hood on the wall.
11
Tighten the 2 upper screws definitively and screw in the 2
lower screws.
12
Connect a pipe (pipe and clips for fixing not supplied, to
be purchased) for fume discharge to the connecting ring
placed above the suction motor unit. The other end of the
pipe must be connected to a fume ejecting device
towards the outside in case the hood is used in suction
version.
13
In case the hood is to be used in filter version, fix the
deflector to the chimney support stirrup and connect the
other end of the pipe to the connecting ring placed on the
deflector.
14
Connect to the power supply.
15
Slide the lower section of the chimney up to complete
covering of the suction group to insert it into the special
housing above the hood.
16
Lift the upper chimney and fix it by 2 screws to the
chimney support stirrup.
Reinstall the grease filter.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.