Fig 1
Fig 2
Fig 3
Creases
Glueboard
Glueboard
Light Blades
BL T5 Lamp
Cord
Cover
Live
Earth
Neutral
Black or Brown
Green or Green/Yellow
White or Blue
ACC 051-001-01
EXTENSION CORDS ARE NOT TO BE USED WITH THIS UNIT.
IMPORTANT SERVICING INSTRUCTIONS
Lamp Replacement T5 15 Watt BL /BLB (UVA 352 nm)
Even though the amount of visible light emitted from the lamp does not appear
to change, the output of UV light diminishes with time. To maintain efficiency,
lamps must be replaced annually. Do not use UV-B or UV-C lamps. The
Genus Eclipse fly trap replacement lamps are available from your local
distributor.
To replace the lamps, follow procedure below:
1. Disconnect from the power source by unplugging the unit from the
receptacle. Always unplug the unit before handling.
2. Open the front cover; it swings open on its hinges by pulling in middle of the
right hand side of the cover. Release the lamp by turning a quarter of a turn
and withdrawing it forward. Be careful not to break the lamp.
3. To install a new lamp, reverse the procedure.
4. Close the cover; push it to the fully closed position.
5. Plug unit in.
Glueboard Replacement
The Genus Eclipse fly trap uses the Universal Glueboard. The Universal
Glueboard is available from your local distributor. To replace the glueboard,
follow the below procedure:
1. Disconnect from the power source by unplugging the unit from the
receptacle. Always unplug the unit before handling.
2. Open the front cover, opening it to its full extent.
3. Remove the glueboard by accessing the boards through the glue free
portion at the bottom edge.
4. Remove the release paper from the new glueboard and fold on the two
horizontal creases taking care not to touch the adhesive area see Fig 1. With
the folded creased end as the bottom, fit into the base of the unit Fig 2. Flex
the board and slide the board into the top glueboard retaining slot slide Fig 3.
5. Close the front cover.
Routine Maintenance
The only maintenance required is to keep the unit clean:
1. Disconnect from the power source by unplugging the unit from the
receptacle. Always unplug the unit before handling.
2. Wipe the unit with a cloth.
3. Change glueboards on a regular basis.
4. Change lamps annually.
5. Remove the spring loaded acrylic Light Blades by lifting up and out. Clean
with soapy water, dry off and polish clean.
Replace by locating the Light Blade into the top socket position first,
compressing the spring allows the bottom end of the Light blade to clear the
bottom socket and to be located and lowered into the bottom socket for
retention.
CAUTION:
THIS PRODUCT IS INTENDED FOR COMMERCIAL INDOOR USE ONLY. THE
DEVICE IS NOT CONSTRUCTED FOR USE OUTDOORS OR IN WET
LOCATIONS AND IS NOT SUITABLE FOR USE IN BARNS, STABLES OR
SIMILAR LOCATIONS. TO AVOID RISK OF FIRE OR ELECTRICAL SHOCK, DO
NOT USE WHERE IT MAY BE EXPOSED TO WATER OR DIRECT SUNLIGHT,
INCLUDING ROOFED OR OPEN PORCHES.
WARNING:
SHOCK HAZARD. DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE.
THE USER MAY REPLACE THE GLUEBOARDS AND BULBS. QUALIFIED
SERVICE PERSONNEL MUST PERFORM ALL OTHER REPAIRS AND
MAINTENANCE.
TO MAXIMIZE EFFICIENCY AND SAFETY, REPLACE GLUEBOARDS
CONTAINING INSECTS AS NEEDED.
THE APPLIANCE IS TO BE KEPT OUT OF THE REACH OF CHILDREN.
THE PRODUCT IS NOT INTENDED FOR USE BY PERSONS (INCLUDING
CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL
CAPABILITIES, OR LACK OF EXPERIENCE OR KNOWLEDGE, UNLESS THEY HAVE
BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE
APPLIANCE BY A PERSON RESPONSILBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH
THE APPLIANCE.
TO MAXIMIZE SAFETY, DISCONNECT THE PRODUCT FROM THE POWER
SUPPLY WHEN NOT IN USE, WHEN CHANGING THE BULB, CLEANING, ETC.
DO NOT ABUSE THE CORD, NEVER CARRY THE PRODUCT BY THE CORD OR
PULL IT FROM THE RECEPTACLE. KEEP CORD AWAY FROM HEAT, OIL AND
SHARP EDGES. IF CORD IS DAMAGED DO NOT USE. TO PROVIDE
CONTINUED PROTECTION AGAINST THE RISK OF ELECTRIC SHOCK,
CONNECT TO PROPERLY GROUNDED OUTLETS ONLY.
DO NOT INSERT FOREIGN OBJECTS INTO THIS UNIT.
THE APPLIANCE IS NOT TO BE USED IN LOCATIONS WHERE FLAMMABLE
VAPOUR OR EXPLOSIVE DUST IS LIKELY TO EXIST.
ELECTRICAL INSTALLATION:
CONSULT A SUITABLY QUALIFIED PERSON IF THE GROUNDING
INSTRUCTIONS ARE NOT COMPLETELY UNDERSTOOD, OR IF IN DOUBT AS
TO WHETHER PROPER GROUNDING EXISTS
GROUNDING INSTRUCTIONS
THE Genus Eclipse FLY TRAP IS EQUIPPED WITH AN APPROPRIATE
3-CONDUCTOR CORD AND 3-PRONG GROUNDING TYPE PLUG TO FIT PROPER
GROUNDING TYPE RECEPTACLES. TO REDUCE THE RISK OF AN ELECTRIC
SHOCK, THE PLUG MUST BE PLUGGED INTO AN APPROPRIATE
RECEPTACLE THAT IS PROPERLY INSTALLED AND GROUNDED.
SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS
Check the voltage requirements for the flytrap and confirm the correct power source
is available. For safe operation it is recommended that the power outlet be fused at
3 amps. This equipment utilises either a standard 110-120v 50/60Hz or 220-240v
50/60Hz outlet with a grounding pin. The power supply must be properly grounded.
If in doubt consult a qualified electrician to confirm that that grounding is present.
The unit is supplied fitted with either a hard wired cable or a loose cable and an IEC
fitting in the unit. Connect the unit to the power supply using the cable supplied. If
the plug connection provided is unsuitable it can be cut off and the unit hard wired
to an electrical junction box that is flush mounted to the wall. The surplus plug should
be discarded of safely. Connect the cable to the power source ensuring that the colour
code is strictly followed and in accordance with the national wiring rules.
THE JUNCTION BOX MUST BE CONNECTED TO THE POWER SOURCE VIA A DUAL POLE
SWITCH OR CIRCUIT BREAKER TO ENABLE THE UNIT TO BE PROPERLY DISCONNECTED
ACCORDING TO NATIONAL WIRING RULES.
®
®
®