background image

Fig 1

Fig 2

Fig 3 

Creases

Glueboard

Glueboard

Light Blades

BL T5 Lamp

Cord

Cover

Live 

Earth 

Neutral 

Black or Brown 

Green or Green/Yellow 

White or Blue

ACC 051-001-01

EXTENSION CORDS ARE NOT TO BE USED WITH THIS UNIT.

IMPORTANT SERVICING INSTRUCTIONS

Lamp Replacement T5 15 Watt BL /BLB (UVA 352 nm)

Even though the amount of visible light emitted from the lamp does not appear

to change, the output of UV light diminishes with time. To maintain efficiency,

lamps must be replaced annually. Do not use UV-B or UV-C lamps. The

Genus  Eclipse fly trap replacement lamps are available from your local

distributor.

To replace the lamps, follow procedure below:

1. Disconnect from the power source by unplugging the unit from the

receptacle. Always unplug the unit before handling.

2. Open the front cover; it swings open on its hinges by pulling in middle of the

right hand side of the cover. Release the lamp by turning a quarter of a turn

and withdrawing it forward. Be careful not to break the lamp.

3. To install a new lamp, reverse the procedure.

4. Close the cover; push it to the fully closed position.

5. Plug unit in.

Glueboard Replacement

The Genus  Eclipse fly trap uses the Universal Glueboard. The Universal

Glueboard is available from your local distributor. To replace the glueboard,

follow the below procedure:

1. Disconnect from the power source by unplugging the unit from the

receptacle. Always unplug the unit before handling.

2. Open the front cover, opening it to its full extent.

3. Remove the glueboard by accessing the boards through the glue free

portion at the bottom edge.

4. Remove the release paper from the new glueboard and fold on the two

horizontal creases taking care not to touch the adhesive area see Fig 1. With

the folded creased end as the bottom, fit into the base of the unit Fig 2. Flex

the board and slide the board into the top glueboard retaining slot slide Fig 3.

5. Close the front cover.

Routine Maintenance

The only maintenance required is to keep the unit clean:

1. Disconnect from the power source by unplugging the unit from the

receptacle. Always unplug the unit before handling.

2. Wipe the unit with a cloth.

3. Change glueboards on a regular basis.

4. Change lamps annually.

5. Remove the spring loaded acrylic Light Blades by lifting up and out. Clean

with soapy water, dry off and polish clean.

Replace by locating the Light Blade into the top socket position first,

compressing the spring allows the bottom end of the Light blade to clear the

bottom socket and to be located and lowered into the bottom socket for

retention.

CAUTION:

THIS PRODUCT IS INTENDED FOR COMMERCIAL INDOOR USE ONLY. THE

DEVICE IS NOT CONSTRUCTED FOR USE OUTDOORS OR IN WET

LOCATIONS AND IS NOT SUITABLE FOR USE IN BARNS, STABLES OR

SIMILAR LOCATIONS. TO AVOID RISK OF FIRE OR ELECTRICAL SHOCK, DO

NOT USE WHERE IT MAY BE EXPOSED TO WATER OR DIRECT SUNLIGHT,

INCLUDING ROOFED OR OPEN PORCHES.

WARNING:

SHOCK HAZARD. DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE.

THE USER MAY REPLACE THE GLUEBOARDS AND BULBS. QUALIFIED

SERVICE PERSONNEL MUST PERFORM ALL OTHER REPAIRS AND

MAINTENANCE.

TO MAXIMIZE EFFICIENCY AND SAFETY, REPLACE GLUEBOARDS

CONTAINING INSECTS AS NEEDED.

THE APPLIANCE IS TO BE KEPT OUT OF THE REACH OF CHILDREN.

THE PRODUCT IS NOT INTENDED FOR USE BY PERSONS (INCLUDING

CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL

CAPABILITIES, OR LACK OF EXPERIENCE OR KNOWLEDGE, UNLESS THEY HAVE

BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE

APPLIANCE BY A PERSON RESPONSILBLE FOR THEIR SAFETY.

CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH

THE APPLIANCE.

TO MAXIMIZE SAFETY, DISCONNECT THE PRODUCT FROM THE POWER

SUPPLY WHEN NOT IN USE, WHEN CHANGING THE BULB, CLEANING, ETC.

DO NOT ABUSE THE CORD, NEVER CARRY THE PRODUCT BY THE CORD OR

PULL IT FROM THE RECEPTACLE. KEEP CORD AWAY FROM HEAT, OIL AND

SHARP EDGES. IF CORD IS DAMAGED DO NOT USE. TO PROVIDE

CONTINUED PROTECTION AGAINST THE RISK OF ELECTRIC SHOCK,

CONNECT TO PROPERLY GROUNDED OUTLETS ONLY.

DO NOT INSERT FOREIGN OBJECTS INTO THIS UNIT.

THE APPLIANCE IS NOT TO BE USED IN LOCATIONS WHERE FLAMMABLE

VAPOUR OR EXPLOSIVE DUST IS LIKELY TO EXIST.

ELECTRICAL INSTALLATION:

CONSULT A SUITABLY QUALIFIED PERSON IF THE GROUNDING

INSTRUCTIONS ARE NOT COMPLETELY UNDERSTOOD, OR IF IN DOUBT AS

TO WHETHER PROPER GROUNDING EXISTS

GROUNDING INSTRUCTIONS

THE Genus  Eclipse FLY TRAP IS EQUIPPED WITH AN APPROPRIATE

3-CONDUCTOR CORD AND 3-PRONG GROUNDING TYPE PLUG TO FIT PROPER

GROUNDING TYPE RECEPTACLES. TO REDUCE THE RISK OF AN ELECTRIC

SHOCK, THE PLUG MUST BE PLUGGED INTO AN APPROPRIATE

RECEPTACLE THAT IS PROPERLY INSTALLED AND GROUNDED.

SAVE THESE INSTRUCTIONS

SAFETY INSTRUCTIONS

Check the voltage requirements for the flytrap and confirm the correct power source

is available. For safe operation it is recommended that the power outlet be fused at

3 amps. This equipment utilises either a standard 110-120v 50/60Hz or 220-240v

50/60Hz outlet with a grounding pin. The power supply must be properly grounded.

If in doubt consult a qualified electrician to confirm that that grounding is present.

The unit is supplied fitted with either a hard wired cable or a loose cable and an IEC

fitting in the unit. Connect the unit to the power supply using the cable supplied. If

the plug connection provided is unsuitable it can be cut off and the unit hard wired

to an electrical junction box that is flush mounted to the wall. The surplus plug should

be discarded of safely. Connect the cable to the power source ensuring that the colour

code is strictly followed and in accordance with the national wiring rules.

THE JUNCTION BOX MUST BE CONNECTED TO THE POWER SOURCE VIA A DUAL POLE

SWITCH OR CIRCUIT BREAKER TO ENABLE THE UNIT TO BE PROPERLY DISCONNECTED

ACCORDING TO NATIONAL WIRING RULES.

®

®

®