Braemar SACC Series Скачать руководство пользователя страница 6

MAINTENANCE SCHEDULE

5

SEELEY INTERNATIONAL –

OWNER

S MANUAL

4

Installation Date:

Items to be done by the

(please sign in the places indicated)

Home Owner/User

Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5

Air filter cleaning

Air filter replacement

Maintain required clearance
around Outdoor unit

Items to be done by a
(Home owner/user must ensure that the technician signs and dates in the places indicated)

Qualified Licensed Technician

Check, clean or replace filter

Check drain from indoor coil

Check Outdoor unit clearances

maintain garden and debris

Check refrigerant charge

Check refrigeration connections for soundness

Check outdoor fans

Check electrical connections

Check ductwork (including but not limited to: duct, fittings, zone dampers, grilles)

Check overall installation

Report to the home owner/user all tasks that require attention

Please NOTE

: the Maintenance Schedule covers Year 1 to Year 5. To preserve your

investment for many years afterwards, we strongly recommend that you continue to
maintain and service the Braemar Add-On Cooling Unit as per the items and frequency set
out in the Schedule, and as indicated elsewhere in this Manual.

Year 1

Date:

Year 2

Date:

Year 3

Date:

Year 4

Date:

Year 5

Date:

Annually

/           /

/           /

/           /

/           /

/           /

/           /

/           /

Installer:

Technician:

Technician:

Technician:

Technician:

Technician:

Technician:

MAINTENANCE & SERVICE

AIR FILTER

INDOOR COIL (REFER PAGE 1)

OUTDOOR UNIT

It is important to check and clean the
air filter as per the Maintenance
Schedule below. A dirty air filter will not
allow the correct amount of clean air to
pass through your air conditioner,
resulting in poor performance and
increased running costs. You should
ask the installer to show you where the
air filter is located.

To clean the air filter, it should be
removed and then cleaned with a
water hose using moderate pressure,
spraying from the internal side. Make
sure it is completely dry before refitting
it. If it is very dirty and cannot be
cleaned, the filter will need replacing.
You should never operate the air
conditioner without the air filter in
place.

The indoor coil does not have any
moving parts, but it is advisable to
have the drain and duct connections
checked on an annual basis (as set
out in the Maintenance Schedule
below). Drains can become blocked by
all types of insects, and rats have been
known to chew through the drain to get
to the water in the pipe.

The Outdoor unit has either one or two
fans, it draws air through the appliance
to expel the heat generated during the
cooling cycle. We recommend

(REFER PAGE 1)

checking that plants haven't grown into
or around the air intake or outlet, along
with other debris that may build up
over time, namely, leaves and the like.

The refrigerant is the life blood of your
air conditioning unit. Not only does the
correct refrigerant charge provide you
with reliable and economical cooling, it
also provides the cooling for the
compressor. A lack of refrigerant, due
to a leak, will cause the compressor to
overheat and expire prematurely. You
will notice a decline in cooling effect
and an increase in power
consumption. Therefore, having a
qualified, licensed technician service
your air conditioner will save you
money in the long term.

REFRIGERANT

PLEASE REFER TO THE NEXT
PAGE FOR THE MAINTENANCE
SCHEDULE

SACC Series Add-On Cooling Unit

Содержание SACC Series

Страница 1: ...OWNER S MANUAL SACC Series Add On Cooling Unit English SACC ...

Страница 2: ...t you maintain your air conditioner and have it regularly serviced Accordingly it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this Manual Compliance with these requirements will prolong the life of your air conditioner Further it is also a condition of warranty cover that the Maintenance Schedule in the M...

Страница 3: ...SEELEY INTERNATIONAL OWNER S MANUAL 1 MAIN COMPONENTS INDOOR COIL OUTDOOR UNIT Indoor Unit Indoor and Outdoor unit operating temperature range 18 C 32 C Outdoor Unit 20 C 48 C ...

Страница 4: ...and the Maintenance Schedule This will also prolong the life of your air conditioner The home owner user should regularly check the Air Inlet side of the Outdoor unit see the diagram on page 1 to ensure grass leaf and other matter are not drawn into or onto the Inlet side of the Outdoor unit Restriction to the air flow across the coil will reduce the system s capacity and result in high operation ...

Страница 5: ...irements may result in the Add On Cooling Unit not performing adequately or at all and void the warranty CONNECTION TO OTHER DUCTED GAS HEATER BRANDS WARNING This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the applian...

Страница 6: ... the Maintenance Schedule below Drains can become blocked by all types of insects and rats have been known to chew through the drain to get to the water in the pipe The Outdoor unit has either one or two fans it draws air through the appliance to expel the heat generated during the cooling cycle We recommend REFER PAGE 1 checking that plants haven t grown into or around the air intake or outlet al...

Страница 7: ...debris Check refrigerant charge Check refrigeration connections for soundness Check outdoor fans Check electrical connections Check ductwork including but not limited to duct fittings zone dampers grilles Check overall installation Report to the home owner user all tasks that require attention Please NOTE the Maintenance Schedule covers Year 1 to Year 5 To preserve your investment for many years a...

Страница 8: ...e symbol a If Yes i Is there air coming out of the outlets in your home ii If No 1 Ensure SCC is set to COOL and the set point is below the room temperature 2 Check and clean return air filter 3 Check and open outlets and or zones 4 Check duct for disconnection or damage 5 After the above have been checked and repaired as required please call b If Yes continue below i Check Circuit Breaker and or ...

Страница 9: ...ck you have the required number of outlets open e Once the above have been checked and repaired as required call 1300 657 506 It is important that you recognise whether the fault is with the Ducted Gas Heater or if the fault is with the Add On Cooling Unit For prompt efficient service please follow the above before calling the appropriate number below When calling the Warranty Service number pleas...

Страница 10: ...traction of the plastic parts in the Unit when the temperature is changing This is a normal condition when the air conditioner has not been used for a long time or during first use of the Unit This is caused by the Indoor unit giving off smells permeated from building material from furniture smoke for example if someone is cooking food or from the duct work When indoor air temperature reaches the ...

Страница 11: ...ge in this event a clicking sound may occur 1 1 Wait for power to resume 1 2 Replace the fuse or reset the breaker 1 3 Check thermostat setting 2 1 Wait a while so the Unit has enough time to cool the room 3 1 This is normal NOTE Seeley International strives for continuous product improvements therefore specifications are subject to change without notice Unit colour may vary slightly from that dep...

Страница 12: ...Ducted Gas Heating 1300 650 644 seeleyinternational com It is the policy of Seeley International to introduce continuous product improvements Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected ...

Отзывы: