MAINTENANCE SCHEDULE
Installation Date:
Items to be done by the
(please sign in the places indicated)
Home Owner/User
Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5
Air filter cleaning
Air filter replacement
Maintain required clearance
around Outdoor unit
Items to be done by a
(Home owner/user must ensure that the technician signs and dates in the places indicated)
Qualified Licensed Technician
Check, clean or replace filter
Check drain from indoor coil
Check Outdoor unit clearances
–
maintain garden and debris
Check refrigerant charge
Check refrigeration connections for soundness
Check outdoor fans
Check electrical connections
Check overall installation
Report to the home owner/user all tasks that require attention
Please NOTE
: the Maintenance Schedule covers Year 1 to Year 5. To preserve your
investment for many years afterwards, we strongly recommend that you continue to
maintain and service the Braemar High Wall Inverter Air Conditioning Unit as per the items
and frequency set out in the Schedule, and as indicated elsewhere in this Manual.
Year 1
–
Date:
Year 2
–
Date:
Year 3
–
Date:
Year 4
–
Date:
Year 5
–
Date:
Annually
/ /
/ /
/ /
/ /
/ /
/ /
/ /
Installer:
Technician:
Technician:
Technician:
Technician:
Technician:
Technician:
OPERATION TIPS
The following events may occur during normal operation:
Compressor protection
•
The compressor cannot restart for 3 minutes after it stops.
The supply air drops below a pre-determined set point; this prevents
the indoor coil from freezing.
A white mist may generate due to a large temperature difference
between air inlet and air outlet on COOL mode in an indoor
environment that has a high relative humidity.
You may hear a low hissing sound when the compressor is running or
has just stopped running.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low
“
squeak
”
sound when the compressor is
running or has just stopped running.
This is caused by heat expansion and cold contraction of the plastic parts
in the Unit when the temperature is changing.
This is a normal condition when the air conditioner has not been used for a
long time or during first use of the Unit.
This is caused by the Indoor unit giving off smells permeated from building
material, from furniture or smoke (for example if someone is cooking food).
When indoor air temperature reaches the setting on the remote controller, the
compressor will stop operating and after approximately 60 seconds the indoor
fan will stop blowing air. When the room temperature rises back to the set
point, the indoor fan and the compressor will start again.
1. Protection of the air conditioner.
2. A white mist coming out from the Indoor unit.
3. Low noise of the air conditioner.
4. Dust is blown out from the Indoor unit.
5. A peculiar smell comes out from the Indoor unit.
6. FAN operation during COOL mode.
•
•
•
•
12
MSHV
Series High Wall Inverter Unit
D1S
SEELEY INTERNATIONAL –
OWNER
’
S MANUAL
13