12

TROUBLESHOOTING

7

SYMPTOM

POTENTIAL SOLUTION

Verify your program setpoint time entries. The heating and

cooling programs utilize the same setpoint times, but have

individual setpoint temperatures for the

MORN

,

DAY

,

EVE

and

NIGHT

setpoints. See

Setting Your Energy Saving Program

section of this manual.
Thermostat Program has been temporarily overridden and

program indicator is flashing in display. Wait until next setpoint

and the temporary override will expire or change the setpoint

manually for comfort.
Thermostat program is in Permanent Hold (Vacation) Mode and

HOLD

and

TEMP

is showing in display. Press

HOLD

button to

release permanent hold and return the thermostat to normal

program operation.

Thermostat turns
heating or cooling
system on too often
or not often enough.

Increase or decrease temperature differential setting as

appropriate to provide the desired performance level. See

Setting Temperature Differential and Residual Cooling Fan

Feature

section of this manual.

Thermostat does not
turn on heating or
cooling system.

Check to see if

OFF

is shown in display. This indicates that the

system is turned off at the thermostat. Move the system

selector switch to the

HEAT

or

COOL

position. After the

compressor short cycle protection 5-minute period expires the

system should start within a minutes time.
Compressor protection features may be in effect due to

compressor short cycle conditions, power outages or rolling

blackouts. See

Compressor Protection Feature

section for full

explanation of this feature.
Heating or cooling system may be malfunctioning. Call a

professional service technician to verify system operation.

Thermostat turns on
heating instead of
cooling.

Check thermostat wiring to make sure that the heating and

cooling stages are connected to the correct terminals on the

wiring terminal block. See

Installation

and

Wiring Diagrams

sections of this manual.

Thermostat turns on
cooling instead of
heating.

Check thermostat wiring to make sure that the heating and

cooling stages are connected to the correct terminals on the

wiring terminal block. See

Installation

and

Wiring Diagrams

sections of this manual.

Thermostat will not
follow program
setpoints.

Check current time of day, day of week program settings. Make

sure to verify

AM/PM

indicator is accurately displaying desired

time settings. See

Setting Current Time of Day and Day of Week

section of this manual.
Check to see if

OFF

is shown in display. This indicates that the

system is turned off at the thermostat. Move the system

selector switch to the

HEAT

or

COOL

position. After the

compressor short cycle protection 5-minute period expires the

system should start within several seconds.

Low battery indicator
is shown in
thermostat display.

Replace batteries immediately to maintain proper system

operation. See

Low Battery Detection and Replacement

section of this manual.

OFF

is shown in

thermostat display
and heating or
cooling system will
not start.

This indicates that the system is turned off at the thermostat.

The thermostat must be in

HEAT

or

COOL

modes of operation to

control the heating or cooling system. Move the system selector

switch to the

HEAT

or

COOL

position.

Thermostat display
is blank.

It is possible that the batteries are drained and not providing

power for the thermostat to control the system. Replace

batteries immediately to maintain proper system operation. See

Low Battery Detection and Replacement

section of this manual.

If you replace the batteries and the display does not appear, call

a professional service technician to verify thermostat and

system performance.

13

SYMPTOM

POTENTIAL SOLUTION

LO

is shown in the

thermostat display
where the room
temperature is
normally displayed.

The temperature sensed by the thermostat is lower than the 40˚

F (5˚ C) lower limit of the thermostats display range. The display

will return to normal after the sensed temperature rises within

the 40˚ to 99˚ F (5˚ to 37˚ C) display range. If the temperature in

the controlled space seems to be normal, wait for the

thermostat to acclimate to the correct room temperature. If the

room seems to be colder than usual, turn on the heating system

to raise the temperature as needed for comfort within the room.
This condition could occur from the system being turned off

during a cold weather period or upon installation when the

thermostat has been stored for a long period of time in a cold

vehicle or location prior to being installed. The thermostat

should be allowed to warm up prior to installation to allow

proper heating control once installed.

HI

is shown in the

thermostat display
where the room
temperature is
normally displayed.

The temperature sensed by the thermostat is higher than the

99˚ F (37˚ C) upper limit of the thermostats display range. The

display will return to normal after the sensed temperature

lowers within the 40˚ to 99˚ F (5˚ to 37˚ C) display range. Turn on

the cooling system or use other methods to lower the

temperature accordingly.
This condition could occur from the system being turned off

during an exceptionally warm period or upon installation when

the thermostat has been stored for a long period of time in a

warm vehicle or location prior to being installed. The thermostat

is equipped with a mechanical high temperature safety switch

that will turn off the system should the temperature exceed 99˚

F (37˚ C).

TROUBLESHOOTING

7

cont.

Содержание Premier 5050

Страница 1: ...emperature Freeze Protection Compressor Protection Changing Fahrenheit F to Celsius C Low Battery Detection and Replacement Replacing the Batteries Resetting Thermostat TROUBLESHOOTING WIRING DIAGRAMS 1 2 3 4 5 6 7 8 5 1 3 1 3 2 5 2 5 3 5 4 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 5 3 1 5 3 2 5 4 1 5 4 2 5 4 3 6 8 1 Always turn off power to the air conditioning or heating system prior to installing rem...

Страница 2: ...ng Control B B Reversing Valve Heating O O Reversing Valve Cooling C None Cap the Wire 24 Volt AC Transformer Common 3 3 INSTALLATION 4 After labeling and removing all wires from terminals unscrew the existing thermostat mounting base from wall Make sure to secure wires to prevent them from slipping back into the hole in the wall NOTE This thermostat is designed for use with a 24 Volt AC low volta...

Страница 3: ...t Make sure to locate the positive ends of the batteries and match them with the positive terminals located in the battery compartment NOTE If you installed the batteries prior to accomplishing steps 14 thru 17 then you will need to reset the thermostat to register your thermostat switch configurations prior to programming Gently press the RESET button on the front of the thermostat using a paper ...

Страница 4: ...current time of day note AM PM indicator in display and the current day of week correctly to avoid problems with program execution This must be done prior to entering any program settings Both the heating and cooling programs use the same setpoint times but allow different setpoint temperatures This thermostat is pre programmed with setpoint times and temperatures recommended by the U S Environmen...

Страница 5: ...in flashing 6 Press the or buttons to change the setpoint temperature to the desired setting in 1 F increments 0 5 C press PROG button The thermostat will now display the DAY setpoint time and temperature Again you will see the hour portion of the setpoint time and the AM PM indicator will be flashing 7 Follow steps 4 through 6 to set the setpoint times and temperatures for the DAY EVE and NIGHT s...

Страница 6: ...st be in the HEAT position for this feature to be active This feature will allow the thermostat to initiate a call for heat on standard heating non heat pump applications to provide a minimum amount of heat even if the batteries are dead or missing This feature is only active on standard heating non heat pump applications and is not available on single stage heat pump applications 11 NOTE Resettin...

Страница 7: ...ressor short cycle protection 5 minute period expires the system should start within several seconds Low battery indicator is shown in thermostat display Replace batteries immediately to maintain proper system operation See Low Battery Detection and Replacement section of this manual OFF is shown in thermostat display and heating or cooling system will not start This indicates that the system is t...

Страница 8: ...oling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains The default setting is 60 seconds This can be changed to disable this feature or shorten the time period if desired See Setting Residual Cooling Fan Feature section of this manual The room is too warm or too cold See Review Set Temperature section of this manual to verify the c...

Страница 9: ...r liability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our...

Отзывы: