background image

User Manual                                                                     20

FAN AUTO

Status

Indicator

Status Indicators

  

Status indicators appear in the display to let you know if your system is heating, cooling or off.

HEAT ON

  Heating system is running.

COOL ON

  Cooling system is running.

AUX

 

  Auxiliary stage of heating is running

     

  (multi-stage heat pump systems only). 

EMER

   Emergency heating system is running 

     

  (heat pump systems only).

ADJ

 

  Temperature adjustment limit has been reached.

     

  Thermostat is connected to Wi-Fi network (flashes if 

     

  connection is lost).

 
     

      Thermostat battery is low 

(see Thermostat Maintenance, page 26)

.

Содержание BlueLink 7205

Страница 1: ...tat For Systems Up to 3 Heat 2 Cool User Manual 2017 Braeburn Systems LLC All Rights Reserved Made in China 7205 110 01 Store this manual for future reference Read all instructions before proceeding See Wi Fi Setup Guide for Wi Fi Setup Instructions ...

Страница 2: ...ram Schedule 12 Programming a 7 Day Residential Schedule 14 Programming a 5 2 Day Residential Schedule 16 4 Operating Your Thermostat Setting the System Control Mode 17 Setting the Fan Control Mode 18 Setting the Temperature 19 Status Indicators 20 Program Event Indicator 21 Resetting the Thermostat 21 5 Additional Operation Features Auto Changeover Mode 22 Adaptive Recovery Mode 23 Compressor Pro...

Страница 3: ... control and monitor thermostat from a smartphone tablet or computer 7 day 5 2 day or non programmable Auto or manual changeover Large 3 sq in bright blue backlit display is easy to read Extra large display characters make viewing settings even easier User selectable filter monitor reminds you of required filter maintenance Precise temperature accuracy keeps you in control of your comfort Convenie...

Страница 4: ...1 About Your Thermostat User Manual 4 FAN AUTO 1 2 3 4 7 8 10 5 9 6 ...

Страница 5: ...i Fi flashes when connection has been lost System Status Indicator Displays information about the status of the system Set Temperature Displays the current set point temperature Low Battery Indicator Indicates when the batteries need to be replaced Time of Day Displays the current time of day Program Event Indicator Displays the program event Day of the Week Displays the current day of the week 1 ...

Страница 6: ...User Manual 6 1 About Your Thermostat DAY TIME INSTRUCTIONS FAN AUTO 11 12 13 14 17 18 15 16 19 ...

Страница 7: ...and day of the week RETURN Button Returns to normal mode from program or a program override HOLD Button Enters Exits the HOLD mode program bypass PROG Button Selects programming mode or press for 3 seconds to select SpeedSet SYSTEM Button Selects the system you want to control Reset Button Resets current time program and user settings Battery Compartment Located in the back of thermostat Thermosta...

Страница 8: ...the User Options menu press and hold the RETURN button for approximately 3 seconds until the screen changes and displays the first User Option Press the SpeedBar or to change the setting for the displayed User Option After you have changed your desired setting press RETURN to advance to the next User Option After reaching the last user setting the thermostat will return to normal mode DAY TIME INS...

Страница 9: ...play screen 2 Extended Hold Period LONG LONG Selects long permanent hold mode 24 HRS Selects 24 hour temporary hold mode 3 Thermostat Lock Code 000 0 9 Select a 3 digit lock code of 0 9 for each digit 4 Wi Fi Clear WIFI WIFI No changes to Wi Fi network settings WIFI CL Clears Wi Fi network settings NOTE Some user options may not be available depending on how your thermostat was configured in the I...

Страница 10: ...erature indefinitely When 24 HRS is selected the thermostat will hold your temperature for 24 hours and then return to the current program at that time Not available in non programmable mode Thermostat Lock Code User Option 3 The Thermostat Lock Code sets a 3 digit code that you may use at any time to lock or unlock the thermostat Setting the code in the user options mode does not activate the loc...

Страница 11: ...peedBar up or down to adjust the hour press DAY TIME 3 Press the SpeedBar up or down to adjust the minute press DAY TIME 4 Press the SpeedBar up or down to adjust the day of the week 5 Press RETURN to exit NOTE If the Wi Fi feature is used the clock will adjust automatically to the time zone and DST Daylight Savings Time set up in the Wi Fi feature 3 Setting Your Program Schedule DAY TIME ...

Страница 12: ...of the following programming options 7 day programming mode with 4 events per day default 5 2 weekday weekend programming mode with 4 events per day Non Programmable mode NOTE If this thermostat was configured In the Installer Settings to be non programmable then you cannot set a user program If you press the PROG or HOLD buttons the word NONE will appear in the display indicating there is no prog...

Страница 13: ... F 29 C Time 6 00 am Heat 70 F 21 C Cool 78 F 26 C Time 10 00 pm Heat 62 F 17 C Cool 82 F 28 C 4 Event All Days Residential 7 Day Programming Factory Settings Weekday Weekend MORN DAY EVE NIGHT Time 6 00 pm Heat 70 F 21 C Cool 78 F 26 C Time 8 00 am Heat 62 F 17 C Cool 85 F 29 C Time 6 00 am Heat 70 F 21 C Cool 78 F 26 C Time 10 00 pm Heat 62 F 17 C Cool 82 F 28 C 4 Event Time 6 00 pm Heat 70 F 21...

Страница 14: ...peedSet programming mode All 7 days of the week will appear and the hour will be flashing 2 Press SYSTEM to select HEAT or COOL 3 Press the SpeedBar up or down to adjust the hour for the MORN morning event Press PROG 4 Press the SpeedBar up or down to adjust the minute for the MORN event Press PROG 5 Press the SpeedBar up or down to adjust the temperature for the MORN event Press PROG 6 Press the ...

Страница 15: ... to adjust the hour for the MORN morning event Press PROG 5 Press the SpeedBar up or down to adjust the minute for the MORN event Press PROG 6 Press the SpeedBar up or down to adjust the temperature for the MORN event Press PROG 7 Press the SpeedBar up or down to adjust the fan setting for the MORN event Press PROG 8 Repeat steps 4 7 for your DAY EVE and NIGHT events 9 If needed repeat steps 3 7 t...

Страница 16: ...s SYSTEM to select HEAT or COOL 3 Press the SpeedBar up or down to adjust the hour for the MORN morning event Press PROG 4 Press the SpeedBar up or down to adjust the minute for the MORN event Press PROG 5 Press the SpeedBar up or down to adjust the temperature for the MORN event Press PROG 6 Press the SpeedBar up or down to adjust the fan setting for the MORN event Press PROG 7 Repeat steps 3 6 f...

Страница 17: ...t modes NOTE Depending on how your thermostat was configured some system modes may not be available AUTO The system will cycle between heating and cooling automatically based on your program set points AUTO will be displayed with either HEAT or COOL COOL Only your cooling system will operate OFF Heating and cooling systems are off HEAT Only your heating system will operate EMER Operates a backup h...

Страница 18: ...hrough the different modes NOTE Depending on how your thermostat was configured some fan modes may not be available AUTO The system fan will run only when your heating or cooling system is running ON The system fan stays on CIRC The system fan will run intermittently to help circulate air and provide more even temperature distribution when the heating or cooling system is not active ...

Страница 19: ...ode the set temperature will change back to your original programmed settings when your next scheduled change in temperature occurs Extended Adjustment Press the HOLD button so that HOLD appears in the display screen Press the SpeedBar up or down to adjust the current set temperature See Extended Hold Period page 10 NOTE If this thermostat was configured to be non programmable you will not have a ...

Страница 20: ...system is running COOL ON Cooling system is running AUX Auxiliary stage of heating is running multi stage heat pump systems only EMER Emergency heating system is running heat pump systems only ADJ Temperature adjustment limit has been reached Thermostat is connected to Wi Fi network flashes if connection is lost Thermostat battery is low see Thermostat Maintenance page 26 ...

Страница 21: ...cheduled event NOTE You will not see a program event indicator while in HOLD or Non Programmable Mode Resetting the Thermostat This thermostat provides you with a reset button that will erase all of your user settings and programming The reset feature does not affect the Installer Settings To reset the thermostat use a small object such as a tooth pick or paperclip and gently press the button loca...

Страница 22: ...tches between heating and cooling when the room temperature meets the programmed heating or cooling set points To operate properly the thermostat requires a dead band setting to eliminate program conflicts The dead band is set in the Installer Settings See Installer Guide The default setting is 3 F Therefore you will not be able to set your heat or cool temperature within 3 F of each other If a se...

Страница 23: ...m temperature ARM ON Reach temperature BY schedule time ARM OFF Start to change temperature AT scheduled time Example ARM ON Heat set to 62 overnight and warm up to 70 at 7 00 AM the thermostat will turn on early to reach 70 BY 7 00 AM Example ARM OFF Heat set to 62 overnight and warm up to 70 at 7 00 AM the thermostat will start heating AT 7 00 AM Setting the thermostat to Hold Emergency Heat or ...

Страница 24: ...Code is set in the User Options portion of this manual See Setting User Options page 8 10 Once the code is set the thermostat can be locked or unlocked at any time by entering that code To lock or unlock the thermostat press and hold the DAY TIME and HOLD buttons together for 5 seconds The screen will change displaying 000 Press the SpeedBar or to enter the first digit of your lock code and then p...

Страница 25: ...will be locked or unlocked depending on its previous state When locked the word LOCK appears in the display Figure 1 If an invalid code is entered the word NO will briefly appear indicating that an incorrect code was entered Figure 2 Figure 1 Figure 2 FAN AUTO ...

Страница 26: ...thermostat if 24 volt AC power is not connected See Installer Guide If batteries become low a battery indicator will appear in the display You should change your batteries immediately when you see the low battery signal by following these instructions 1 Remove thermostat body by gently pulling it from base 2 Remove old batteries and replace with new batteries 3 Make sure to correctly position the ...

Страница 27: ...cked by a 5 year limited warranty Limitations apply For limitations terms and conditions you may obtain a full copy of this warranty Visit us online www braeburnonline com warranty Phone us 866 268 5599 Write us Braeburn Systems LLC 2215 Cornell Avenue Montgomery IL 60538 5YEAR WARRANT Y LIMITED ...

Страница 28: ...nonline com Call us toll free 866 268 5599 U S 630 844 1968 Outside the U S 2017 Braeburn Systems LLC All Rights Reserved Made in China 7205 110 01 Store this manual for future reference For additional information visit www braeburnonline com For online access visit www bluelinksmartconnect com ...