background image

Installer Guide

Universal Programmable Smart Wi-Fi Thermostat

1

 

Specifications    

Installation and Wiring   

Quick Reference    

Installer Settings   

Wireless Remote Sensors   

System Testing

To prevent damage to the thermostat, never use a sharp instrument 

to press the touchscreen keys. Always press keys with your fingers.

Attention

• Possible electric shock or damage to equipment can occur.

• Disconnect power before beginning installation.

Caution

This thermostat requires 24 Volt AC Power or 2 properly installed “AA” Alkaline 

batteries for proper operation. 

If connecting this thermostat to a Wi-Fi network, 

a 24 VAC common (C wire) is required

.

For use only as described in this manual. Any other use will void warranty.

7320

 

Up to 3 Heat / 2 Cool Heat Pump

 

Up to 2 Heat / 2 Cool Conventional

 

 with wireless Humidity Control*

Warning

For installation by experienced service technicians only.

®

  

   

This thermostat is compatible with:

   

•  Single stage heat / cool conventional and heat pump systems

   

•  Conventional systems up to 2 stages of heating and 2 stages of cooling

   

•  Heat pump systems up to 3 stages of heating and 2 stages of cooling

  

Electrical and control specifications:

   

•  Electrical Rating:  24 Volt AC

   

•  1 amp maximum load per terminal, 6 amp maximum load

   

•  AC Power:  18 – 30 Volts AC

   

•  DC Power:  3.0 Volt DC (2 “AA” Alkaline Batteries Included)

   

•  Control Range:  45° – 90° F (7° – 32° C)

   

•  Temperature Accuracy:  +/- 1° F (+/- .5° C)

   

•  Outdoor Temperature Display Range:  -40° - 120° F (-40° - 49° C)

 

 

Terminations:

   

Rc, Rh, C, W2/AUX, W1/E, L, A, O/B, G, Y2, Y1, K, S2, S1

1

Specifications

7320-100-01

Model number is located on back of thermostat.

* Wireless Humidity Control requires accessory model 7330. 

See Wi-Fi Setup Guide for Wi-Fi Setup Instructions

TM

 

 

 

Содержание 7320

Страница 1: ... 2 Cool Heat Pump Up to 2 Heat 2 Cool Conventional with wireless Humidity Control Warning For installation by experienced service technicians only This thermostat is compatible with Single stage heat cool conventional and heat pump systems Conventional systems up to 2 stages of heating and 2 stages of cooling Heat pump systems up to 3 stages of heating and 2 stages of cooling Electrical and contro...

Страница 2: ... appliances concealed pipes chimneys and outside walls Installer Guide 2 Install your new Braeburn thermostat in 4 basic steps 1 Install the Sub Base 2 Provide Power 3 Connect Your Wires 4 Attach Thermostat to Sub Base Install the Sub Base Remove the sub base from the body of the thermostat Mount the sub base as shown below Warning Disconnect power before beginning installation 2 Installation and ...

Страница 3: ...ing this thermostat to a Wi Fi network a 24 VAC common C wire is required Batteries Installed as Shown Terminal Function Description Rc Input 24 Volt AC Cooling Transformer Dual Transformer Systems Only Rh Input Power Connection 24 Volt AC Heating Transformer C Input 24 Volt AC Transformer Common W2 AUX Output W2 2nd Stage Conventional Heat AUX Auxiliary Heat Heat Pump W1 E Output W1 1st Stage Con...

Страница 4: ... cooling transformer 4 If needed for system Provide disconnect and overload protection as required 2 HEAT 2 COOL Single or Dual transformer Set System Type to 22CONV Rh 24 Volt AC Power heating transformer note 2 Rc 24 Volt AC Power cooling transformer note 2 W1 Heat Relay Stage 1 W2 Heat Relay Stage 2 Y1 Compressor Relay Stage 1 Y2 Compressor Relay Stage 2 note 4 G Fan Relay C 24 Volt AC Transfor...

Страница 5: ...oling W2 Auxiliary Heat Relay 2nd stage heating note 3 E Emergency Heat Relay note 3 G Fan Relay C 24 Volt AC Transformer Common note 1 L Optional System Fault Monitor note 4 2 HEAT 2 COOL No Auxiliary Heat Set System Type to 32HP Rh 24 Volt AC Power Rc Connected to Rh with supplied Jumper Wire O B Changeover Valve note 2 Y1 Compressor 1 Relay 1st stage heating cooling Y2 Compressor 2 Relay 2nd st...

Страница 6: ...body with the sub base 2 Carefully push the thermostat body against the sub base until it snaps in place NOTE Additional options are configured in the Installer Settings section S1 S2 A Economizer Fresh Air or Output Control K Share a WireTM Module note 2 NOTES Additional Wiring Options 1 Can be used to connect a Braeburn indoor or outdoor wired remote sensor 2 Can be used to share a wire on exist...

Страница 7: ...Indicator Displays information about the status of the system Hold Mode Indicator Indicates if the thermostat is in HOLD mode Low Battery Indicator Indicates when the batteries need to be replaced Wi Fi Wireless Indicator Indicates when connected to Wi Fi wireless flashes when connection has been lost Fan Indicator Indicates when the system fan is running Quick Reference Instructions Stored in slo...

Страница 8: ...Selects programming mode or press for 3 seconds to select SpeedSet mode HOLD Enters Exits the HOLD mode program bypass DAY TIME Sets the current time and day of the week BACK Moves back in setting and programming modes NEXT Moves forward in setting and programming modes RETURN Returns to normal mode from program or settings modes CONFIG Enters the User and Installer settings modes HUMID Displays o...

Страница 9: ...r clock 4 Temperature Scale F DEG F DEG Select for Fahrenheit display C DEG Select for Celsius display 5 Auto Changeover oF AUTO oF AUTO Disables Auto Changeover mode ON AUTO Enables Auto Changeover mode 11CONV Select for 1H 1C Conventional system 22CONV Select for 2H 2C Conventional system 6 System Type 11CONV 11HP Select for 1H 1C Heat Pump system 22HP Select for 2H 2C Heat Pump system 32HP Sele...

Страница 10: ...5 Select a Dead Band of 2 3 4 or 5 F Dead Band note 10 BAND 1 2 or 3 C for Auto Changeover mode 23 Compressor Balance NO BALC NO BALC Disables Balance Points Point notes 4 10 0 50 BALC Select a Compressor Balance Point of 0 50 F 18 10 C 24 Auxiliary Heat Balance NO BALA NO BALA Disables Balance Points Point notes 4 10 70 40 BALA Select a Auxiliary Heat Balance Point of 70 40 F 21 4 C 25 Economizer...

Страница 11: ... selected the system automatically switches between heating and cooling modes There is a 5 minute delay when switching from heating to cooling or cooling to heating in auto changeover mode NOTE Also see Auto Changeover Dead Band in option 22 6 System Type Selects the system type for your installation NOTE Changes made to this option will reset options 7 through 14 back to their default values depe...

Страница 12: ...SENS NOTE This option does not apply to the Braeburn outdoor sensor When an outdoor sensor is connected wired or paired wireless the thermostat automatically recognizes it and no further configuration is necessary 21 Lockout Security Level Selects the level of keypad lockout when the thermostat is locked Level 2 locks the entire thermostat including the front reset button Level 1 locks everything ...

Страница 13: ... humidity set point limit to auto AUTO or manual MAN When AUTO is selected humidity control is provided automatically based on the outdoor temperature Selecting MAN allows you to manually control the level of humidity 30 Dehumidification note 12 For use with an external dehumidifier Select between dehumidification disabled OFF a normally inactive NI or normally active NA relay depending on the req...

Страница 14: ...You cannot mix wired and wireless remote sensors of the same type i e mixing an indoor wireless remote sensor and an indoor wired remote sensor Replacing a Thermostat If you are replacing a thermostat that is paired with an existing wireless sensor you will need to clear the remote sensor and pair it again with the newly installed thermostat 1 Install the new thermostat 2 On the wireless remote se...

Страница 15: ...L mode of operation if the outside temperature is below 50º F 10º C This could possibly damage the controlled cooling system and may cause personal injury This thermostat includes an automatic compressor protection feature to avoid potential damage to the compressor from short cycling When testing the system make sure to take this delay into account NOTE The compressor delay can be bypassed by pre...

Страница 16: ...asures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Equipment interface module thermostats and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for ...