This thermostat requires 24 Volt AC Power or two (2) properly installed “AA” 

Alkaline batteries for proper operation. When connecting 24 Volt AC Power 

the batteries may be installed as a backup. 

Thermostat installation and all 

components of the system shall conform to Class II Circuits per NEC code.

For use only as described in this manual. Any other use 

will void warranty.

2020NC

Single Stage Heat / Cool

Conventional and Heat Pump

1

  

Specifications

About Your Thermostat

Installation

System Testing

Setting User Options

6

  Setting Your Program Schedule

7  

Operating Your Thermostat

8

  Additional Operation Features

9

  Thermostat Maintenance

®

Warning

Turn off power to the heating or cooling 

equipment before installation.

Attention

For installation by experienced service 

technicians only.

2220NC

Up to 2 Heat / 1 Cool Conventional

Up to 2 Heat / 1 Cool Heat Pump

Read all instructions before proceeding.

   This thermostat is compatible with:

   

• Single stage heat / cool conventional and heat pump systems

   

• Conventional systems up to 2 heat / 1 cool (2220NC only)

   • 

Single compressor heat pump systems with an auxiliary heat stage (2220NC)

   

• 250 – 750 millivolt heat only systems

  

Electrical and control specifications:

   

• Electrical Rating:  24 Volt AC

   

• 1 amp maximum load per terminal

   

• AC Power:  18 – 30 Volts AC

   

• DC Power:  3.0 Volt DC (2 “AA” Alkaline Batteries Included)

   

• Control Range:  45° – 90° F (7° – 32° C)

   

• Temperature Accuracy:  +/- 1° F (+/- .5° C)

   Terminations

   

• 2020NC – Rc, Rh, O, B, Y1, W1, G, C

   

• 2220NC – Rc, Rh, O, B, Y1, E/W1, G, W2, C

1

Specifications

2020NCW-100-05

Model number is located on back of thermostat

Programmable 

Thermostats

Detailed 

User Guide

Содержание 2020NC

Страница 1: ...uipment before installation Attention For installation by experienced service technicians only 2220NC Up to 2 Heat 1 Cool Conventional Up to 2 Heat 1 Cool Heat Pump Read all instructions before procee...

Страница 2: ...nt set point temperature Service Filter Indicator Displays service maintenance reminders 1 2 3 4 5 7 5 6 8 9 6 7 8 10 9 10 1 2 4 3 Reset Button Resets thermostat back to factory defaults System Switch...

Страница 3: ...the slot on the top of the base 3 Installation Warning Disconnect power before beginning installation Thermostat Location Install the thermostat approximately 5 feet 1 5m above the floor in an area t...

Страница 4: ...ions Terminal Function Description W1 E Output W1 1st Stage Conventional Heat E Emergency Heat Relay W2 Output 2nd Stage Heat Auxiliary Heat Additional Terminations 2220NC only Provide Power For 24 Vo...

Страница 5: ...onal 2 Remove factory installed jumper for dual transformer systems 3 In dual transformer systems transformer common must come from cooling transformer 4 If needed for system Provide disconnect and ov...

Страница 6: ...t Typical Wiring Configurations NOTE The Installer Switch option will be configured in the next step Heat Pump Systems 1 HEAT 1 COOL No Auxiliary Heat Set Installer Switch to HP Rh 24 Volt AC Power Rc...

Страница 7: ...ssed by pressing the reset button on the front of the thermostat All user settings will be returned to factory default 1 Move the SYSTEM switch to HEAT mode 2 Press to raise the set temperature a mini...

Страница 8: ...de choose from 7 day 5 2 Day weekday weekend programming or non programmable Temperature Differential User Option 2 and 3 The differential setting is the temperature control range that your thermostat...

Страница 9: ...or a required air filter replacement by flashing the SERVICE FILTER segment in the display When the selected interval has been reached and required cleaning or replacement has been performed touch the...

Страница 10: ...se settings then no further programming is necessary MORN DAY EVE NIGHT Time 6 00 pm Heat 70 F 21 C Cool 78 F 26 C Time 8 00 am Heat 62 F 17 C Cool 85 F 29 C Time 6 00 am Heat 70 F 21 C Cool 78 F 26 C...

Страница 11: ...to adjust the temperature for the MORN event Press PROG 6 Repeat steps 3 5 for the DAY EVE and NIGHT events 7 If needed repeat steps 2 6 to program the opposite mode HEAT or COOL 8 Press RETURN to exi...

Страница 12: ...ps 3 5 for your DAY EVE and NIGHT events 7 Repeat steps 3 6 for your Saturday and Sunday S SU program 8 If needed repeat steps 2 7to program the opposite mode HEAT or COOL 9 Press RETURN to exit 7 Ope...

Страница 13: ...n temporarily bypassed and will resume at the next scheduled event Note You will not see a program event indicator while in HOLD Mode Resetting the Thermostat This thermostat provides you with a reset...

Страница 14: ...ry indicator will appear in the display You should change your batteries immediately when you see the low battery signal by following these instructions 1 Remove thermostat body by gently pulling it f...

Страница 15: ...copy of this warranty Visit us online www braeburnonline com warranty Phone us 866 268 5599 Write us Braeburn Systems LLC 2215 Cornell Avenue Montgomery IL 60538 5YEAR WARRANTY LIMITED Braeburn System...

Отзывы: