* Loading path for
media
Loading the Media
Control Panel
Move the label roll guard
horizontally to the end of label
spin
dle then flip down
the label
roll guard.
(1)
Place the roll of media on the label
supply spindle. Flip up the label
roll guard. Move the label roll
guard horizontally to gently
fit t
he
width of label
roll.
(2)
Pull label roll leading edge
forward through the
media guide
bar, damper, media sensor and
place the label leading edge onto
the platen roller.
(3)
Adjust the label guide to
fit t
he
width of the label
.
(4)
Using the front display panel, set the media sensor type and calibrate the selected sensor. (See “Media Sensor
Calibration” in the box on the right side of this page)
Note: Re-calibrate the gap/black-mark sensors
w
hen changing media. The sensor location is marked by a triangle
mark
▽
at the sensor housing. Please make sure the gap or black mark is at th
e location where media
gap/black
mark
will pass throug
h for sensing.
(4)
Unlock the media sensor lock lever
to adjust the media sensor posi-
tion and lock the media sensor
lock lever. (see note
below
)
(5)
Close the print head mechanism
by pushing the both sides of print
head mechanism. Make sure the
latches are engaged securely.
(6)
* For more information and features about this printer, please refer to the User’s Manual inside the CD disk.
Make sure the ribbon and label media are
installed properly as described above.
Turn off the printer po
w
er.
Hold do
w
n the
button and turn on the
printer
powe
r.
Do not release the buttons until printer LCD
s
how
s "
Calibrating
...".
Make sure the ribbon and label media are installed properly as
described above.
Press the button to enter the main menu.
Press and buttons to select the "
Setup
"
option and press button to enter this option. And
enter the "
Sensor
" option.
When enter this option, the sensor type in the right side of ">"
icon is the current sensor setting. Press the
and
to select the sensor type, and press the
button to calibrate the media sensor.
Media Sensor Calibration
This utility is used to calibrate the sensitivity of the media sensor. The media sensor should be calibrated
w
henever
changing the label media or after printer initialization.
Method 1:
1.
2.
3.
4.
Method 2:
1.
2.
3.
4.
Technical Support
For repair or technical assistan
ce, fi
nd your regional Brady Tech Support
office b
y going to:
•
In the America
s: www.
bradyid.com
•
In Asia
: www.
bradyid.com/ap
1.
2.
3.
4.
Self-test printout is used to check if there is any heater element damaged on the print head and sho
w
s current
printer con
figu
rations.
Install the ribbon and the label media.
Press the button to enter the main menu.
Press and buttons to scroll the cursor to the "
Diagnostics
" option and press button to
enter this option.
And press and buttons to scroll the cursor to the "
Print Config.
" option and press
button to execute this option.
Printer Self-test
Turn off the printer
powe
r.
Press and hold and button at
the same time then turns on the printer’s po
w
er.
Do not release the buttons until printer LCD
s
how
s "
Initializing
..."
Press the
button to enter the main menu.
Press and buttons to select the "
Service
"
option and press button to enter this option.
And press and buttons to scroll the cursor
to "
Initialization
" option and press button to
restore printer settings to defaults.
Printer Initialization
Printer Initialization
w
ill restore printer settings to defaults.
Method 1:
1.
2.
3.
Method 2:
1.
2.
3.
Note: The 4" wide media is required for printing the printer configurations.
LED
Indication
Status
Keys
Function
The printer power is
turned off
The printer power is
turned on
Printer is ready
Pause
Downloading data into
printer
Printer is ready
"CARRIAGE OPEN" or
“CUTTER ERROR”
"NO PAPER", "PAPER
JAM" or "NO RIBBON"
1. Enter the menu
2. Exit from a menu or cancel a
setting and return to the
previous menu
Pause/Resume the printing
process
Advance one label
Scroll up the menu list
Scroll down the menu list
Enter/Select cursor located
option
Off
On
On
Blinking
Off
On
Blinking