background image

4

Bradley TouchTime

®

 Individual Built-In Wall Shower with Concealed Supplies

 Installation

8/23/2017 

Bradley • 

215-1855 Rev. A; ECN 17-03-011

Make Electrical Connections

2

A

Install a 120VAC/12V DC 
plug in adapter in a remote 
location a safe distance from 
the shower room . 

B

Connect cable from solenoid to TouchTime 
module . Connect cable from pushbutton 
to TouchTime module . Connect cable 
from DC adapter to TouchTime module .

WARNING  DO NOT put the 120VAC/12VDC plug in adapter in the shower room. Check local codes and 

ordinances for proper location and connection requirements. Conformity to local codes is the 
responsibility of the installer.

WARNING  DO NOT activate power to your shower until installation is complete.

WARNING  Verify that the electrical source to the fixture is 12V DC.

NOTICE:  Connection of leads other than shown below may cause permanent damage to the electrodes.

Pushbutton 

Cable

Pushbutton 

Cable

TouchTime 

Module Cable

Activation of the pushbutton takes place only when it 
is released, thereby preventing "hold open" activation.

Plug-In 

Adapter Cable

TouchTime 

Module

Adjusting the TouchTime Module

The TouchTime module is set at the factory with the selector 
switch in position 7. This provides a 60 second time out period.

To adjust the TouchTime module to a different time 
out period, turn the selector switch to the desired time 
out setting (4 through 9 for no flush, A though F for 24 
hours flush) as indicated on the module label .

A

The 24 hour flush function will activate water flow for a period of 60 seconds any 
time there has been no activation within the past 24 hours. This function is used 
to help clear stagnant water from the plumbing system and can provide some 
measure of prevention against the formation of bacteria in supply pipes.

3

Содержание TouchTime 1C

Страница 1: ... entire installation manual to ensure proper installation When finished with the installation file this manual with the owner or maintenance department Compliance and conformity to local codes and ordinances is the responsibility of the installer Separate parts from packaging and make sure all parts are accounted for before discarding packaging material If any parts are missing do not begin instal...

Страница 2: ...le is controlled by a separate solenoid valve allowing each user to activate a flow of tempered water from one spray nozzle with a pushbutton or piezo switch for 60 seconds Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Activation time can be adjusted in the field Solenoid Valve An electronically controlled solenoid valve serves as t...

Страница 3: ...cture hardware by installer 2 1 4 57mm 4 1 4 108mm 2 3 8 60mm 1 2 13mm 1 1 2 38mm 3 76mm 5 7 8 149mm 5 16 Plastic Tubing Elbow 1 4 NPTM x 5 16 Tube 1 2 IPS Piping supplied by installer 2 10 24 Screw supplied by Bradley and 2 10 wall anchors supplied by installer Reducer Showerhead Escutcheon 4 1 4 20 Anchors supplied by installer and 4 screws supplied by Bradley Refer to recommended shower heights...

Страница 4: ...C NOTICE Connection of leads other than shown below may cause permanent damage to the electrodes Pushbutton Cable Pushbutton Cable TouchTime Module Cable Activation of the pushbutton takes place only when it is released thereby preventing hold open activation Plug In Adapter Cable TouchTime Module Adjusting the TouchTime Module The TouchTime module is set at the factory with the selector switch in...

Страница 5: ... oil use a quality commercial detergent or caustic cleaner Apply in accordance to the manufacturer s instructions and in the direction of the polish lines Precautions Avoid prolonged contact with chlorides bleaches salts bromides sanitizing agents thiocyanates pesticides photography chemicals and some foods and iodides on stainless steel equipment especially if acid conditions exist NOTICE Do not ...

Отзывы: