2
Bradley TouchTime
®
Individual Built-In Wall Shower with Concealed Supplies
Installation
8/23/2017
Bradley •
215-1855 Rev. A; ECN 17-03-011
Pre-Installation Information
TouchTime
The 1C TouchTime
®
Shower controls water flow at each station through the use of a timer module . When the pushbutton is
pushed, a signal is sent controlling the opening and closing of the fixture's solenoid valve . The valve then delivers water to the
fixture for a preset length of time of 60 seconds (timing is adjustable on module) .
Recommended showerhead heights
Bradley 1C TouchTime showers can be installed at any height (see
recommended heights) .
NOTE: The heights listed are measured from
finish floor to showerhead tip.
Components
Material:
All exposed parts are stainless steel or polished chrome-plated brass .
Supply Inlet:
The supply inlet to the valve assembly is 1/2" IPS .
TouchTIme and Solenoid Valve:
Each TouchTime mechanical pushbutton/piezo switch activates a flow of water . Each nozzle
is controlled by a separate solenoid valve, allowing each user to activate a flow of tempered water from one spray nozzle with a
pushbutton or piezo switch for 60 seconds . Each valve uses less than half the maximum amount of hot water allowed by the ANSI/
ASHRAE/IES 90A-1980 Standard . Activation time can be adjusted in the field .
Solenoid Valve:
An electronically controlled solenoid valve serves as the metering mechanism . Few moving parts provide reliable
metering performance and the solenoid is unaffected by chemicals and minerals often present in municipal water supplies .
Supplies Required for Installation
• 1/2" IPS piping and 1/2" IPS tempered water supply piping and fittings (for solenoid)
• four 1/4"-20 wall anchors for showerhead and two #10 wall anchors for pushbutton assembly
• Teflon tape or teflon pipe dope
• 110 VAC power source for 12V DC plug in adapter (available from Bradley as an option)
• OPTIONAL: Bradley recommends installing an electrical cut-off switch to the unit . This feature allows no accidental
water delivery during regular maintenance and service .
Age
Male
Female
Adult
6' (1 .83m)
5'6" (1 .68m)
Teenage
6' (1 .83m)
5'6" (1 .68m)
Pre-Teen
5'6" (1 .68m)