Installation
SN2013, SN2033 - Infrared
Bradley •
215-923 Rev. M; ECN 17-00-002
8/21/2017
5
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM . Size supply lines
accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of dimensions shown to
pass through washfountain shroud and sprayhead .
Drain through floor: Stub up 3" (76) .
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional):
Nominal Copper Tube
1-1/2" NPT Drain
Key
(mm)
Type B
Centrally rising vent -
passes through center of
unit (P-Trap furnished) .
Type O
Off-line vent
(P-Trap supplied
by Installer .)
Type A
Off-line vent
(P-Trap supplied by
Installer .)
Type H
Centrally rising vent -
passes through center of
unit (P-Trap furnished) .
Supplies from Above
Supplies from Below or Through Wall
Top View
Top View
When running supplies and drain through wall, use same horizontal measurements as shown in Top View.
Position openings above the finished floor, at the following dimensions (to center):
Drain: Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
11-3/4"
(298)
11-3/4"
(298)
18-7/16"
(468)
18-7/16"
(468)
10-5/16"
(262)
10-5/16"
(262)
11-1/2"
(292)
11-1/2"
(292)
12-1/16"
(306)
12-1/16"
(306)
2-9/16"
(65)
6-3/4"
(298)
6-3/4"
(298)
7-15/16"
(202)
11-3/4"
(298)
11-3/4"
(298)
Optional Wall
DRAIN
Optional Wall
DRAIN
H
H
C
C