Installation
LVAD2
Bradley
• 215-1850 Rev. A; ECN 17-08-002
4/17/2017
7
Mounting for Standard, ADA and TAS height shown.
Structural Rough-Ins
Points A, B and C require sufficient backing
compliant with local building codes.
WARNING Ensure bowl is completely seated in
the wall bracket and securely fastened
to the wall at point A.
(mm)
A
A
B
B
CL
CODE
DESCRIPTION
QTY.
A
Install (1) 3/8" wall anchor with a minimum pull-out force of 1,000 lbs. per local codes at locations shown
2
B
Provide structural backing compliant with local building codes.
2
C
Install wall anchor with a minimum pull-out force of 100 lbs. per local codes at locations shown
4
Wall Bracket
RIM HEIGHT
VERTICAL HEIGHT ADJUSTMENTS
FIXTURE STYLE
33½"
No Adjustment
Standard Height, ADA, TAS and CSA
30½"
Subtract 3"
Juvenile, ADA and TAS
C
C
28-1/8"
(723)
Bottom
of
Bracket
33-1/2"
(851)
24-1/8"
(612)
13-1/8"
(333)
27-5/8"
(701)
27-5/8"
(701)
24-1/8"
(612)
3/4"
(19)
36-1/2" (927)
25" (635)
25" (635)
25-1/4"
(640)
Secure bracket to wall using min. (2)
3/8" anchor bolts to the left of C/L and
min. (2) 3/8" anchor bolts to the right
of C/L. The (2) anchor bolts to the right
of C/L must be min. 16" apart from the
anchor bolts to the left of C/L. When
mounting is complete, check to ensure
the bracket is level. See Step 1: Bracket
Mounting for more information.
31-1/2"
(800)