background image

Step 3: Carefully remove the 

volute from the base using a bent 

socket wrench.

Step 4:  Open the scroll 

approximately 45°.

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Содержание Aerix 2905-2873

Страница 1: ...Service Manual for 2905 2873 How to Remove the Cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 2: ...Cover Specification Steel White Epoxy Enameled Replacement Part Number P15 433 WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 3: ...Reminder Disconnect power to the unit before removing the cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 4: ...w the two screws with wrench provided Part P15 441 Step 2 Remove the cover vertically taking care to avoid Damaging Internal Components Damaging the Cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 5: ...Service Manual for 2905 2873 How to Remove the Heating Element WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 6: ...00 W Material Winding in NICROM body in MICA Automatic resetting circuit breakers to protect against overheating Replacement Part Numbers P15 424 for UL models P15 425 for CE models WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 7: ...Reminder Disconnect power to the unit before removing the cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 8: ...Removing the Heating Element Step 1 Remove the fan scroll lid Step 2 Remove the fan wheel by unscrewing the center nut WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 9: ...he clips on the upper part of the heating element Step 4 Carefully remove the scroll from the base using a hexagonal socket wrench a click connection pushing down only WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 10: ... Element Step 5 Open the scroll approximately 45 Step 6 Disconnect the two cables of the heating element the white ones from the circuit board WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 11: ...e Heating Element Step 7 Remove the heating element from its housing To replace the heating element follow the above steps in reverse WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 12: ...Service Manual for 2905 2873 How to Remove the Motor WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 13: ...ee Vibration free and quiet operation Self resetting safety circuit breakers to eliminate overheating and burnout Replacement Part Numbers P15 434 for UL models P15 435 for CE models WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 14: ...Reminder Disconnect power to the unit before removing the cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 15: ...Removing the Motor Step 1 Remove the fan scroll lid Step 2 Remove the fan wheel by unscrewing the center nut WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 16: ... the Motor continued Step 3 Carefully remove the volute from the base using a socket wrench Step 4 Open the volute approximately 45 WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 17: ...d Step 5 Disconnect the cables of the motor from the electric plate Step 6 Remove the Motor Note To replace the motor follow the same steps in reverse WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 18: ...Service Manual for 2905 2873 How to Remove the Sensor and Circuit Board WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 19: ...urns dryer on and off Detection distance between 10 and 25 cm sensitivity is easily adjusted by the jumper Replacement Part Numbers P15 438 for UL models P15 439 for CE models WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 20: ...Reminder Disconnect power to the unit before removing the cover WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 21: ...Removing the Circuit Board Step 1 Remove the fan scroll lid Step 2 Remove the fan wheel by unscrewing the nut in the middle WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 22: ...Step 3 Carefully remove the volute from the base using a bent socket wrench Step 4 Open the scroll approximately 45 WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 23: ...t the 4 cables of the Motor the red and brown and of the heating element the white ones Step 6 Disconnect the cables of the power terminal WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 24: ...Step 7 Pull out the circuit board by flexing both front clips To replace the circuit board follow the same steps in reverse WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Страница 25: ...JUMPER A High sensitivity Detection distance 20 25 cm B Low sensitivity Detection distance 10 15 cm The hand dryers are supplied with the jumper on low sensitivity WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Отзывы: