Aerada 1100 Series High Arc Faucet
Installation Instructions
4
3/8/07
Bradley Corporation • 215-1558 Rev. A; EN 07-202
Installation Instructions
1. Turn off water supply to the existing faucet and
remove the faucet.
2. Mount the spout and rubber washer to top of base
as shown in the illustration. Install the second
rubber washer, steel washer and spout nut
underneath the base. Securely tighten the spout
nut.
3. Tighten the spout nut securely to prevent the spout
from rotating. If necessary, support the spout from
above to prevent twisting. Do not overtighten.
IMPORTANT: Do not use a wrench on
spout or inlet tubes.
4.
AC Only:
Plug the power supply into the
appropriate 110/115V wall outlet. Connect the
power supply female plug into the faucet male
plug.
NOTE: Power supply is equipped with an 11.8"
(30cm) cord. For multiple faucet installation, an
additional extension cord is provided. Refer to the
wiring diagram packaged with the faucet.
5. Connect the hot and cold water lines to the supply
pipes. Use
Teflon tape
on the threads to ensure a
leak-free joint. Tighten connections securely.
6. Turn the water supply on.
7. Remove the protective covering from the sensor.
8. Place a hand in front of the sensor for 15 seconds
to activate for the first time.
RUBBER
WASHER
SPOUT
RUBBER WASHER,
STEEL WASHER,
SPOUT NUT
HOT AND COLD
WATER SUPPLY
AC High Arc Faucet shown; DC model is similar.