20
THERMOSTAT ADJUSTMENT - White Rodgers gas control.
160°F Control 180°F Control
Figure 2
The thermostat dial is set to its lowest temperature setting when shipped from the factory.
Remember that lower temperature settings are more energy efficient
. Adjust the
temperature by turning the thermostat dial. It is suggested that the starting point setting not be
greater than the “
” or “ ” mark on the thermostat dial (approximately 120°F [
48.9°C
]) as
indicated above. Rotate the thermostat dial
clockwise
to decrease the temperature
setting. Rotate the thermostat dial
counter-clockwise
to increase the temperature
setting. Adjust the dial until the minimum acceptable temperature is achieved (See figure 2
above for approximate temperature settings).
Robertshaw gas control.
160°F Control 180°F Control
Figure 3
The thermostat dial is set to its lowest temperature setting when shipped from the factory.
Remember that lower temperature settings are more energy efficient
. Adjust the
temperature by turning the thermostat dial. It is suggested that the starting point setting not be
greater than the “ ” mark on the thermostat dial (approximately 120°F [
48.9°C
]) as indicated
above. Rotate the thermostat dial
counter-clockwise
to decrease the temperature
setting. Rotate the thermostat dial
clockwise
to increase the temperature setting.
Adjust the dial until the minimum acceptable temperature is achieved (See figure 3 above for
approximate temperature settings).