background image

PV Series

 

 

Introduction

The new Bradford White RG1PV & RG2PV water heaters are designed to provide reliable performance with 

enhanced standard features. New design features include reliable spark to pilot ignition system, enhanced 

diagnostics, simplified servicing, quiet operation, additional vent lengths, and Bradford White Defender 

Safety System

®

(not available on all models).

Spark to Pilot Ignition System - employing the spark to pilot ignition system promotes reliable and consistent 

pilot and main burner ignitions to provide hot water on demand.

Integrated Immersion Thermostat/Gas Control Valve with LED - was developed for ease of troubleshooting 

by providing simple diagnostic codes to pinpoint an installation or component performance issue.

Powerful Blower - will eliminate problems with difficult venting situations.

Quiet and Cool Blower Operation  - blower noise is significantly reduced for both interior and exterior 

environments.  Cooler operation increases blower life by reducing bearing wear and noise.

Rugged Wiring Connections - receptacle type connections promote error free wiring.

Increased Vent Lengths - increased venting performance is achieved while maintaining Energy Factor & 

FHR (not available on all models) performance.

The RG1PV & RG2PV water heaters use a combustion system where flue gases are combined with dilution 

air to reduce the flue gas temperature in the blower.  The diluted flue gases are evacuated to the exterior 

through low temperature vent materials.  The gas control maintains water temperature, ignition sequence 

and regulates gas flow. A safety circuit consisting of a pressure switch and blower temperature switch 

verifies proper conditions exist for safe and reliable operation.  If a situation outside of normal operating 

parameters exists, the gas control diagnostic LED will flash a code to positively identify an operational issue.

This service manual is designed to facilitate problem diagnosis and enhance service efficiency.

Please read the service manual completely before attempting service on this new series of power vent 

models.  

How the Safety System Works

During normal operation, air for combustion is drawn into the water heater through the opening in the jacket.  

This air travels down and around the combustion chamber and enters through holes in the very bottom of the 

corrosion-resistant combustion chamber.  The air then travels up through the oriented flame arrestor plate 

louvers, where the velocity of air is increased and its direction altered.  The air then mixes in a normal 

manner with supplied gas and is efficiently combusted, producing low NOx emissions.

In the unlikely event trace amounts of flammable vapors are present in the air flowing into the combustion 

chamber, the vapors are harmlessly ignited by the burner.  If flammable vapors are in sufficient quantity to 

prevent normal combustion, the flammable vapor sensor recognizes this and shuts down the pilot and main 

burner.  Should the flammable vapor continue to burn, the flame arrestor plate prevents the flames from 

traveling backwards and igniting vapors outside of the combustion chamber. This feature is only on models 

with inputs less than or equal to 75,000 BTU/hr.

4

Содержание RG1PV40S

Страница 1: ...ervice To be performed ONLY by qualified service providers Models Covered by This Manual Through The Wall Models RG1PV40S N X RG1PV50S N X RG1PV55H N X RG2PV40T N X RG2PV50H N X RG2PV50T N X RG2PV75H...

Страница 2: ...lacement 19 II Pressure Switch Testing Replacement 20 III Blower Testing Replacement 22 IV Blower Temperature Switch Testing Replacement 24 V Gas Control Testing Replacement 26 VI Flammable Vapor Devi...

Страница 3: ...as detectors are available Contact your gas supplier or plumbing professional for more information WARNING FAILURE TO INSTALL AND MAINTAIN A NEW LISTED X TEMPERATURE AND PRESSURE RELIEF VALVE WILL REL...

Страница 4: ...ol maintains water temperature ignition sequence and regulates gas flow A safety circuit consisting of a pressure switch and blower temperature switch verifies proper conditions exist for safe and rel...

Страница 5: ...ols Required for Service Manometer Multi Meter Electronic Probes Thermometer Water Pressure Gage Various Hand Tools A liquid U tube type or a digital magnahelic type can be used This device is used to...

Страница 6: ...Gas Control ECO Limit Residential 188 F 87 C Commercial 199 F 93 C Residential Temperature Set Point Range 60 F 16 C to 160 F 71 C approximate temperatures Commercial Temperature Set Point Range 80 F...

Страница 7: ...e Roof 1 45 16 8 7 2 1 Through the Roof 2 40 15 2 7 2 1 Through the Roof 3 35 10 7 7 2 1 Through the Roof 4 30 9 2 7 2 1 3 Diameter 10 2 cm Vent Connector Lengths Terminating of Elbows Maximum Straigh...

Страница 8: ...gh the Roof 1 55 16 8 7 2 1 Through the Roof 2 50 15 2 7 2 1 Through the Roof 3 45 13 7 7 2 1 4 Diameter 10 2 cm Vent Connector Lengths Terminating of Elbows Maximum Straight Length ft m Minimum Strai...

Страница 9: ...2 1 Through the Roof 1 45 13 7 7 2 1 Through the Roof 2 40 12 2 7 2 1 Through the Roof 3 35 10 7 7 2 1 4 Diameter 7 6 cm Vent Connector Lengths Terminating of Elbows Maximum Straight Length ft m Minim...

Страница 10: ...ond maximum 1 second minimum Post purge 15 Seconds PS Fault Delay failed open close Retry after 2 minutes Soft Lockout Retry after 5 minutes ECO Limit Lockout Indefinite see page 27 Verify Resistive D...

Страница 11: ...ty circuit is closed the control waits 4 seconds gas control LED flashes 2 times with 3 second pause Gas control waits 2 minutes then blower runs for 30 seconds This cycle repeats until safety circuit...

Страница 12: ...conds Abnormal Operation 1 Flammable Vapor Sensor or Simulated Resistive Device Fault a If the resistance is greater than 70 000 Ohms the gas control immediately turns off all outputs Control waits an...

Страница 13: ...minutes before turning on the blower for another 30 seconds to see the circuit close This cycle repeats as long as there is a call for heat or until the circuit closes c Pressure switch or blower temp...

Страница 14: ...s off the blower and flashes 6 times then 3 times with 3 second pause The gas control waits 5 minutes before repeating the ignition sequence b Flame sensed out of sequence the gas control only looks f...

Страница 15: ...pause Undesired false pilot flame present 1 Pilot valve stuck in open position Replace gas control page 31 PV Series 15 Observe green LED indicator on electronic gas control Error flash codes are disp...

Страница 16: ...ctrode 4 Wire damage to pilot assembly or bad connection at gas valve 5 Insufficient combustion air 6 Gas pressure is out of specification 1 4 Page 19 5 Refer to installation manual 6 Page 26 Six four...

Страница 17: ...ating Pilot flame should be stable some causes for an unstable pilot flame are a Water heater vent is less than the allowable vent length b Gas pressure is out of specification c Pilot flame not fully...

Страница 18: ...ove burner assembly from combustion chamber Step 7 Thoroughly inspect burner surface area and burner port area and remove any loose debris Step 8 Unscrew burner from main burner orifice Step 9 Remove...

Страница 19: ...hms setting check continuity through igniter flame sense wire Replace pilot if no continuity Step 10 Visually inspect igniter flame sense electrode for deterioration Replace pilot as necessary Electro...

Страница 20: ...e Switch Testing Step 1 Position power switch on gas control to the OFF position Step 2 Remove the three screws Phillips screw driver from control access cover on blower assembly and remove cover see...

Страница 21: ...s not have 2 screws carefully remove it from the housing see photo 4b Step 4 Disconnect tubing from pressure switch see photo 5 Step 5 Disconnect yellow wires from pressure switch see photo 6 Step 6 R...

Страница 22: ...Position gas control power switch to ON position and adjust control to call for heat Step 2 Remove the three screws Phillip s screw driver from control access cover on blower assembly and remove cove...

Страница 23: ...screws 1 4 nut driver Step 7 Remove blower with gasket from water heater Blower Installation Step 8 Clean any debris from jacket head of water heater Step 9 Set new blower with gasket in place using...

Страница 24: ...esting Position power switch on gas control to the OFF position Step 1 Remove the three screws Phillip s screw driver from control access cover on blower and remove cover see photo 14 Step 2 Locate bl...

Страница 25: ...yellow wire leads from switch Step 5 With an appropriate tool such as side cutters snip the retaining lug from the blower housing to allow removal of temperature switch see photo 18 Step 6 Remove swit...

Страница 26: ...ep 4 Follow instructions located on the lighting instructions label and proceed to light the main burner and observe manometer reading Step 5 Proper operating range for Natural Gas is 4 0 0 5 W C Prop...

Страница 27: ...ing the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual Gas Control Disassembly Reassembly Step 1 Set the gas contr...

Страница 28: ...control is reassembled burner assembly is reinstalled and the gas supply line is reconnected resume water supply to water heater Be sure tank is full of water before relighting Step 10 To resume oper...

Страница 29: ...of temperature sensor connector insert the second probe see caution into either of the outside wire positions see photo 19 Alternate the probe on the outside position to the opposite outside wire pos...

Страница 30: ...737 725 713 In Degrees F Determine Water Temperature Inside Tank Step 1 Position gas control power switch to OFF position Step 2 Draw approximately 4 gallons of water from the drain valve into a conta...

Страница 31: ...x drive screws from FLANGE SECTION of inner door c Remove right side inner door and set aside Be careful not to damage gasket material in inner door Step 7 Removal of Gas Control a Disconnect main bur...

Страница 32: ...jacket burner access door when reinstalled f Firmly place right side inner door flange against the left side inner door flange and secure with 2 hex drive screws from step 6b DO NOT OVER TIGHTEN SCREW...

Страница 33: ...ensor from gas control Step 3 Using a multi meter set to the ohms setting check resistance of flammable vapor sensor Resistance must be between 3 000 ohms and 48 000 ohms If outside of this range repl...

Страница 34: ...ries 34 Safety Circuit Voltage Trace NOTE This procedure assumes a cool tank Remove three screws Phillips Screw driver from control access cover on blower and remove cover see photo 19 WARNING 115 vol...

Страница 35: ...35 115 VAC Circuit Trace Step 1 Verify 115 VAC and proper polarity at wall outlet Step 2 With unit plugged in and control power switch in the ON position verify LED status WARNING 115 volt potential e...

Страница 36: ...5 Visually inspect inlet nipple dip tube Inlet nipple dip tube should be free of cracks and any blockage Hydrojet slots should be open and free of any blockage Any damage such as cracks restriction du...

Страница 37: ...o damage pipe threads Step 5 Visually inspect outlet nipple anode Outlet nipple anode should show signs of depletion this is normal If depletion is of the original anode diameter approximately diamete...

Страница 38: ...and 27b Step 7 Inspect baffle or core for deterioration missing restrictors Clean any scale or debris build up Replace with new baffle or core as necessary Step 8 Reinstall baffle or core into flue tu...

Страница 39: ...und opening Dirt or debris If the gasket is not affected by any of the above gasket replacement is not required If replacement is required proceed to Inner Door Gasket Replacement Procedure Inner Door...

Страница 40: ...n the radiused channel of the inner door around the feedline Using the hex drive screws from step 3c secure left side inner door in place DO NOT OVER TIGHTEN SCREWS Step 9 Position pilot tube and igni...

Страница 41: ...astener holes of the combustion chamber are aligned with right side inner door slotted opening Verify seal integrity around combustion opening Secure right side inner door using hex drive screws from...

Страница 42: ...vacuum to remove any scale or other debris accumulation Using a soft brush clear jacket openings from any dirt dust restrictions or other obstructions Step 6 Remove any debris from burner assembly per...

Страница 43: ...the vent terminals in relation to each other and terminals from other appliances can have an effect on the potential for blockage due to ice or snow See the installation instructions for recommended p...

Страница 44: ...15 Wire Harness 16 T P Valve 17 NPT Plug H Models only 18 Burner Assy 19 Main Burner 20 Main Burner Orifice 21 Pilot Assy 22 Pilot Orifice 23 Feedline 24 Outer Door 25 Right side Inner Door 26 Screw...

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ......

Отзывы: