Bradford White RE350T6-1NC Series Скачать руководство пользователя страница 11

 

11

Water Connections continued-

 

 

Utility Models (See Figure 2)

 

All utility models are supplied with inlet and outlet nipples located in a plastic bag 
attached to the water heater. The hot and cold water locations are identified on 
the side of the water heater. Apply appropriate amount of thread sealant to the 
provided nipples and install nipples into the side of the tank. For 20 gallon utility 
models, install the supplied anode/nipple combination at the HOT outlet location. 
Connect the hot and cold water lines to the nipples using unions. Install a listed 
temperature-pressure relief valve in the opening on the side of the water heater. 
Install a vacuum relief anti-siphon device in the cold water inlet line when using 
side cold water connection. 
 
The 6 and 12 gallon models are equipped for installation with either side or top 
water connections. They are shipped from the factory with the alternate top 
connections plugged. The alternate top inlet is supplied with a dip tube. If the top 
water connections are needed, remove pipe plugs from the alternate top 
connections, apply appropriate amount of thread sealant to the provided nipples 
and install nipples in desired top location. Apply appropriate amount of thread 
sealant to the pipe plugs and install pipe plugs in the side locations. Install a 
vacuum relief anti-siphon device in the cold water inlet line when using side cold 
water connection.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 2 

 

 

Содержание RE350T6-1NC Series

Страница 1: ...HESE INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING For your family s comfort safety and convenience it is recommended this water heater be installed and serviced by a plumbing professional A Spanish language version of these instructions is available by contacting the manufacturer listed on the rating plate La version espanola de estas instruccions se puede obtener al escribirle ...

Страница 2: ...r new Electric Water Heater We strongly recommend that you contact a plumbing professional for the installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning your warranty please consult the plumbing professional from whom your water heater was purchased For you...

Страница 3: ...ing Instructions The manufacturer will not be held liable for damage resulting from alteration and or failure to comply with these instructions This water heater has been designed and certified for the purpose of heating potable water The installation and use of this water heater for any purpose other than the heating of potable water may cause damage to the water heater and create a hazardous con...

Страница 4: ...ese instructions After reading these installation and operating instructions select a location for the water heater where the floor is level and is easily accessible to a power supply and water connections It is recommended that the water heater be located near the center of greatest hot water usage to prevent heat loss through the pipes DO NOT locate the water heater where water lines could be su...

Страница 5: ...ations cannot be avoided a suitable drain pan must be installed under the water heater The drain pan must have a minimum length and width of at least 4 in 10 2 cm greater than the diameter of the water heater The drain pan as described above can be purchased from your plumbing professional The drain pan must be piped to an adequate drain The piping must be pitched for proper drainage CLEARANCES 1 ...

Страница 6: ...expansion DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control this situation After installation of the water lines open the main water supply valve and fill the water heater While the water heater is filling open several hot water faucets to allow air to escape...

Страница 7: ...o the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valve Verify that the combination temperature and pressure relief valve complies with local codes If the combination temperature and pressure relief valve does not comply with local codes replace it with one that does Follow ...

Страница 8: ...water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet at the time it is open CAUTION INCREASING THE THERMOSTAT SETTING ABOVE THE PRES...

Страница 9: ...ature by mixing cold and hot water in branch supply lines Such valves are available from the manufacturer of this water heater or a local plumbing supplier Please consult with a plumbing professional APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than 5 seconds 145...

Страница 10: ...figure 1A For bottom inlet models 503 models the cold water inlet is located on the side of the drain valve see figure 1B Connect the hot and cold water lines to the installed nipples using unions Install a listed temperature pressure relief valve in the opening on the side of the water heater Figure 1A Top Inlet Models Figure 1B Bottom Inlet Models ...

Страница 11: ...g on the side of the water heater Install a vacuum relief anti siphon device in the cold water inlet line when using side cold water connection The 6 and 12 gallon models are equipped for installation with either side or top water connections They are shipped from the factory with the alternate top connections plugged The alternate top inlet is supplied with a dip tube If the top water connections...

Страница 12: ...de panels and force the top panel upward This will separate the top panel from the water heater and allow further access to the water heater Check drain valve to make sure that it is closed Part the top fiberglass insulation to allow access to the plumbing and electrical connections Connect the cold water supply line and hot water outlet lines using elbows nipples and unions as shown in the diagra...

Страница 13: ...r allow other circuitry Consult your local power company to determine the correct electrical hook up in order to meet local utility and building codes and in order to obtain the most economical rates Also check to find out if you are required to obtain a permit before starting the installation The following chart shows the recommended fuse size for the maximum water heater wattage The maximum watt...

Страница 14: ...ater heater make sure you follow the steps below 1 Disconnect the power supply to the water heater Consult the plumbing professional or electric company in your area for service 2 Close the cold water supply shut off valve 3 Open the drain valve if provided on the water heater by inserting a standard flat head screwdriver into the slot and turning counter clockwise The drain valve has threads on t...

Страница 15: ...hat the plastic terminal shield has not been displaced replace the access panel The water heater is now ready for operation and the main switch can be closed Figure 4 CAUTION Before adjusting thermostat s turn off power supply to the water heater Hotter water increases the risk of scald injury Scalding may occur within five 5 seconds at a temperature setting of 140 F 60 C To protect against hot wa...

Страница 16: ...ls suggested below In some installations the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater Regular inspection and maintenance of the water heater will help to insure safe and reliable operation 1 Annually check the operation of the thermostat s 2 Bi annually check the seal around the heating elements for leaks If there is ...

Страница 17: ...ode rod hot water outlet nipple has been installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in your area will influence the time interval for inspection and replacement of the anode rod Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating pl...

Страница 18: ...Nights ___________________________ Address _____________________________________________________ Supplier _____________________________________________________ Supplier Phone No _________________________________________________________ Manufactured under one or more of the following U S Patents 5 277 171 5 341 770 5 372 185 5 485 879 5 574 822 5 596 952 5 660 165 5 682 666 5 761 379 5 943 984 5 95...

Страница 19: ...19 NOTES ...

Страница 20: ...20 NOTES ...

Отзывы: