background image

 

General Information cont.- 

 

About the Control Panel 

 

Displaying Temperature Setpoint 

 

The water heater control will display the 
temperature setpoint anytime a button on the 
control is pressed. After 30 seconds of 
inactivity, the display will go blank. However, 
the LED indicating the selected operation mode 
will remain lit. To wake the control at any time 
to see the temperature setpoint, press any 
button on the control. 

 

Turning on the Water Heater 

 

There is no power button for this unit. Once the 
water heater is wired and power is supplied, it 
will be on. The display will show the current 
water temperature setting and an LED will 
illuminate, indicating the current operating 
mode. 

To comply with safety regulations, the controls 
are factory preset to 120°F (49°C) and Hybrid 
Mode. It is recommended that the unit be set to 
Heat Pump (Only) Mode to maximize energy 
savings. Operating in Hybrid Mode provides a 
balance of energy savings and hot water use 
convenience.  

Reported energy consumption is based on 
operating the unit in Hybrid Mode at required 
Department of Energy (DOE) test conditions. 
Operating at lower temperature settings or in 
Heat Pump (Only) Mode will provide even 
greater energy savings.

 

 

 

To Adjust the Temperature 

 

 Follow these steps: 

1.  Press the UP or DOWN arrow on the 

control panel keypad to the desired 
temperature. 

2.  Press ENTER to accept the new setting. 

Note:

 To change between °F and °C, 

press and hold MODE. 

 

Control Features 

 
 
 
 
 
 
 
 

 
 

Display 

Displays the current temperature or the number of days for 
vacation mode. To display setpoint if display has gone blank, 
press any button. 

Operating Modes 

(see page 6 for description) 

Vacation 

(see page 6 for description) 

Mode Selector 

Press this button to toggle through the various heating modes. 
Press and hold to switch between °F and °C. 

Arrow Pads 

Use these buttons to manually change the water temperature, or 
to select days for Vacation Mode. 

Enter Key 

Use this button to confirm temperature setting following 
adjustment. 

Filter Reset 

The filter is dirty and requires cleaning when the 

red 

light is 

illuminated. Filter is located on top of the water heater. Press the 
button and hold for 5 seconds to reset filter alarm. 

Содержание RE2H50S 1NCWT Series

Страница 1: ...1NCWT RE2H80T 1NCWT For your family s comfort safety and convenience we recommend this water heater be installed and serviced by a plumbing professional ECO 8384 1 Effective Sept 2020 238 52169 00A 9...

Страница 2: ...on and instruction manual will explain in detail the installation and maintenance of your new Heat Pump Water Heater We strongly recommend that you contact a plumbing professional for the installation...

Страница 3: ...hot water faucet due to a reaction between the sacrificial anode and impurities in the water If this should happen an alternative anode s may be purchased from the supplier that installed this water...

Страница 4: ...e tank of hot water to last about 25 longer as less hot water is mixed in at the shower or faucet Increasing the water temperature setpoint may improve the cleaning performance of dishwashers and wash...

Страница 5: ...mption is based on operating the unit in Hybrid Mode at required Department of Energy DOE test conditions Operating at lower temperature settings or in Heat Pump Only Mode will provide even greater en...

Страница 6: ...d Mode at required Department of Energy DOE test conditions Operating in Heat Pump Only Mode may provide greater savings in energy and operating costs than the claimed savings Electric Only Mode Elect...

Страница 7: ...n and hot water capacity are factors to be considered when selecting the water temperature setting of the water heater Water temperatures above 125 F can cause severe burns or death from scalding Be s...

Страница 8: ...stallation Instructions Local Installation Regulations This water heater must be installed in accordance with these instructions local codes and utility company requirements or in the absence of local...

Страница 9: ...re and pressure relief valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure When such locations cannot be avoided a suitable drain pan must be i...

Страница 10: ...r in the event service is needed A minimum 8 20 3 cm clearance above the water heater to remove the filter for cleaning and for service access and clear access to the front of the water heater is reco...

Страница 11: ...met will lead to higher power consumption increased use of resistance heating elements and or heat pump efficiency reduction Corner Installation Model RE2H50S Model RE2H65T RE2H80T Alcove Installatio...

Страница 12: ...sure reducing valve water meter or water softener A check valve located in the cold water inlet line can cause what is referred to as a closed water system A cold water inlet line with no check valve...

Страница 13: ...r flows through the faucets close them and check all water connections for possible leaks NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER CAUTION For protection agai...

Страница 14: ...oduced in a hot water system served by this water heater when there has been no usage for a long period of time generally two weeks or more HYDROGEN GAS IS EXTREMELY FLAMMABLE To reduce the risk of in...

Страница 15: ...1 watt 3 412 BTUH Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts or persons and to eliminate potential water damage Pi...

Страница 16: ...er is filled Close the faucets and check for water leaks at the water heater drain valve combination temperature pressure relief valve and the hot and cold water connections F11 Fault Code During Inst...

Страница 17: ...round connection is essential The presence of water in the piping and water heater does NOT provide sufficient conduction for a ground Nonmetallic piping dielectric unions flexible connectors etc can...

Страница 18: ...unit and at least 7 in 17 5 cm clearance around the sides of the unit 6 in 15 2 cm clearance for earthquake strap installations with additional clearance on the opposite side of the unit Front of unit...

Страница 19: ...rom the system 4 When a steady stream of water flows from the faucets the water heater is filled Close the faucets and check for water leaks at the water heater drain valve combination temperature pre...

Страница 20: ...hot water heater discharges periodically this may be due to thermal expansion in a closed water system Contact the water supplier or your plumbing contractor on how to correct this Do not plug the re...

Страница 21: ...4 until the water runs clear 6 Close the drain valve and fill the tank BEFORE returning power to the unit The tank is full when water runs out of a nearby open hot water faucet Cleaning the Filter In...

Страница 22: ...ater to run The water heater will continue to produce hot water using the backup resistance heating elements until the condensate drain has been cleared and is able to drain properly Once the drain ha...

Страница 23: ...soft set sealant thread into the port using the torque wrench tighten to 50 5ft lbs of torque 7 Turn water supply ON open a tap to remove any air in the plumbing system inspect for leaks then reassem...

Страница 24: ...Phone Days ________________________________ Nights ______________________________ Address __________________________________________________________________ Supplier _________________________________...

Страница 25: ...t energy efficient models Heat Pump Only and Hybrid the method used to heat the water used a fan that can be heard while running Q The heat pump is not running its normal length of time What causes th...

Страница 26: ...operating range is 35 F T5 ambient 120 F If ambient temperature as viewed by T5 sensor is outside of this range the water heater will switch to Electric Standard Mode for that heating cycle only NO fa...

Страница 27: ...utton becomes free the fault code will clear by itself Dirty Filter F14 5 Filter LED is on and audible alarm is sounding Filter is too dirty to enable proper function of water heater Number of Dirty F...

Страница 28: ...28 Notes...