Bradford White M-I-MS40T6LX Скачать руководство пользователя страница 6

 

6

 
Installation (Locating The Water Heater) continued-

 

 

Water heater corrosion and component failure can be caused by the heating 
and breakdown of airborne chemical vapors. Examples of some typical 
compounds that are potentially corrosive are: spray can propellants, cleaning 
solvents, refrigerator and air conditioning refrigerants, swimming pool 
chemicals, calcium and sodium chloride, waxes and process chemicals. These 
materials are corrosive at very low concentration levels with little or no odor to 
reveal their presence. 

NOTE: DAMAGE TO THE WATER HEATER CAUSED 

BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE 
WARRANTY.  DO NOT OPERATE THE WATER HEATER IF EXPOSURE 
HAS OR WILL OCCUR.  DO NOT STORE ANY POTENTIALLY CORROSIVE 
COMPOUNDS IN THE VICINITY OF THE WATER HEATER. 

 

For exact venting specifications, please consult the Venting section of these 
Installation and Operating Instructions.

  

It is recommended that a minimum 

clearance of 4 inches 

(10.2 cm)

 be provided on the side of the water heater for 

servicing and maintenance of the combination temperature and pressure relief 
valve. 

 

WARNING 

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE 
NOT CERTAIN OF THE FOLLOWING: 
•  Liquefied petroleum gases/propane gas and natural gas have an 
odorant added by the gas supplier that aids in detection of the gas. 
•  Most people recognize this odor as a “sulfur” or “rotten egg” smell. 
•  Other conditions, such as “odorant fade” can cause the odorant to 
diminish in intensity, or “fade”, and not be as readily detectable. 
•  If you have a diminished sense of smell, or are in any way unsure of 
the presence of gas, immediately contact your gas supplier from a 
neighbor’s telephone. 
•  Gas detectors are available.  Contact your gas supplier or plumbing 
professional for more information. 

 

WARNING 

Liquefied petroleum gases/propane gases are heavier than air and will 
remain at floor level if there is a leak.  Basements, crawl spaces, closets 
and areas below ground level will serve as pockets for accumulation of 
leaking gas.  Before lighting, smell all around the appliance area for 
gas.  Be sure to smell next to the floor. 

 

IF YOU SMELL GAS: 
• 

Do not try to light any appliance. 

• 

Do not touch any electric switch; do not use any telephone in 

your building. 
• 

Immediately call your gas supplier from a neighbor’s 

telephone. Follow the gas supplier’s instructions. 
• 

If you cannot reach your gas supplier, call the fire department. 

 

DO NOT OPERATE APPLIANCE UNTIL LEAKAGE IS CORRECTED! 

Содержание M-I-MS40T6LX

Страница 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL FOR YOUR SAFETY Do not store or use gasoli...

Страница 2: ...installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning you...

Страница 3: ...nces 7 Drain Pan Installation 9 Combustion Air Supply 10 Venting 11 Water Connections 12 Gas Connections 15 Gas Conversion Instructions 16 GENERAL OPERATION 20 Lighting and Shutdown Instructions 21 Bu...

Страница 4: ...ter includes the field installation of the following components roof jack air intake tube and heater tie down materials These components for field installation may have been shipped with this heater a...

Страница 5: ...s to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present unless the instal...

Страница 6: ...T ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING Liquefied petroleum gases propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas Most peopl...

Страница 7: ...ith sealant in a smooth and easily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of 6 beneath the water heater Note For Ca...

Страница 8: ...8 Installation continued Figure 1 IMPORTANT The flow of combustion and ventilating air must not be obstructed Minimum Clearances From Combustible Materials A 0 0cm B 0 0cm C 3 7 62cm D 78 1 98mm VENT...

Страница 9: ...final installation 4 Align drain pan hole with hole cut in floor and underside sheathing for air intake 5 Apply 4 diameter circle of silicone around bottom of air intake plate and screws used to secu...

Страница 10: ...the combustion chamber burners and flue tubes with possible damage to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air intake and leg enclosure are required to supply fresh air to t...

Страница 11: ...ened to the top of the water heater and to the adjacent walls with the screws provided See Figure 5 Venting Make certain the flue baffle is in place and centered in the flue tube Cut a 7 1 4 inch 18 5...

Страница 12: ...house Install a shut off valve in the cold water supply line CAUTION If sweat fittings are to be used DO NOT apply heat to the nipples on top of the water heater Sweat the tubing to the adapter befor...

Страница 13: ...Relief Valves The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination temperat...

Страница 14: ...for a long period of time generally two weeks or more Hydrogen gas is extremely flammable To prevent the possibility of injury under these conditions we recommend the hot water faucet to be open for...

Страница 15: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 16: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 6 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Страница 17: ...provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equipped...

Страница 18: ...igure 7 only 1 Follow the instructions above except remove cap from gas regulator and depress and rotate plunger counterclockwise 2 Remove main burner orifice and pilot assembly and replace with RED c...

Страница 19: ...this installation and operation instruction manual 10 Remove equipped for card from cloth bag and attach to gas piping as close to gas control as possible Remove and discard tag attached to water inl...

Страница 20: ...Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockwise The drain valve has threads on...

Страница 21: ...21 Lighting and Shutdown Instructions...

Страница 22: ...al until the minimum acceptable temperature is achieved See Figure 9 above for approximate temperature settings Figure 10 The thermostat dial is set to its lowest temperature setting when shipped from...

Страница 23: ...ot be greater than the mark on the thermostat dial approximately 120 F 48 9 C as pictured above Rotate the thermostat dial clockwise to decrease the temperature setting Rotate the thermostat dial coun...

Страница 24: ...tall an ASSE approved mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch water lines A licensed plumbing professional or loca...

Страница 25: ...t least once a year check the combination temperature and pressure relief valve to insure that the valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several...

Страница 26: ...TION OF THE LENGTH OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED Complete the following information and retain for future reference Model No Serial No Service Phone Days Nights Address Supplie...

Страница 27: ...27 TYPICAL INSTALLATION...

Страница 28: ...ket Top 13 Thermostat w ECO Convertible Nat or L P Gas 3 Fiberglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base A...

Отзывы: