background image

 

5

Locating the Water Heater continued-

 

 
These materials are corrosive at very low concentration levels with little or no 
odor to reveal their presence. 

NOTE: DAMAGE TO THE WATER HEATER 

CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED 
BY THE WARRANTY. DO NOT OPERATE THE WATER HEATER IF 
EXPOSURE HAS OR WILL OCCUR. DO NOT STORE ANY 
POTENTIALLY CORROSIVE COMPOUNDS IN THE VICINITY OF THE 
WATER HEATER. 
 

This water heater must be located in an area where leakage of the tank or 
water line connections and the combination temperature and pressure relief 
valve will not result in damage to the area adjacent to the water heater or to 
lower floors of the structure. When such locations cannot be avoided, a 
suitable drain pan must be installed under the water heater. The drain pan 
must have a minimum length and width of at least 4 in. 

(10.2 cm)

 greater 

than the diameter of the water heater. The drain pan, as described above, 
can be purchased from your plumbing professional. The drain pan must be 
piped to an adequate drain. The piping must be pitched for proper drainage. 

 

CLEARANCES 

 

1.  Minimum clearance to combustible material is 0 inches for the Top, 

Sides, Front, and Rear of this water heater. However, it is 
recommended that 

at least 18 inches (45.7 cm) from the Top, and 

24 inches (61 cm) from the Front.

 Clearance for servicing may be 

reduced down to minimum clearance to combustible material, but 
service time and effort may be greatly increased. 

2.  Increase distances to provide clearances for servicing.  

 

Note: For California installation this water heater must be braced, 
anchored, or strapped to avoid falling or moving during an earthquake. 
See instructions for correct installation procedures. Instructions may 
be obtained from the DSA Headquarters Office, 1102 Q Street, Suite 
5100, Sacramento, CA 95811. 
 

Water Connections

 

 

NOTE: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE 
MAIN WATER SUPPLY VALVE. 

 
After shutting the main water supply valve, open a faucet to relieve the water 
line pressure to prevent any water from leaking out of the pipes while making 
the water connections to the water heater. After the pressure has been 
relieved, close the faucet. The COLD water inlet and HOT water outlet are 
identified on top of the water heater. The fittings at the cold water inlet and 
hot water outlet are dielectric waterway fittings with 3/4” NPT tapered male 
threads. Make the proper plumbing connections between the water heater 
and the plumbing system in the house. Install a shut-off valve in the cold 
water supply line. 

Содержание LE110U3

Страница 1: ...URE TO COMPLY WITH THESE INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING For safety and convenience it is recommended that this water heater be installed and serviced by a plumbing pro...

Страница 2: ...ell as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning your warranty please consult the plumbing professional from whom your water heater was p...

Страница 3: ...use damage to the water heater and create a hazardous condition and nullify the warranty Do not use this appliance if any part has been submerged in water The plumbing professional responsible for the...

Страница 4: ...ter so that access panels and drain valves are accessible Some models are not equipped with a drain valve For those models install a drain tee in the cold water inlet as close as practical to the wate...

Страница 5: ...nt and Rear of this water heater However it is recommended that at least 18 inches 45 7 cm from the Top and 24 inches 61 cm from the Front Clearance for servicing may be reduced down to minimum cleara...

Страница 6: ...be used DO NOT apply heat to the nipples on top of the water heater Sweat the tubing to the adapter before fitting the adapter to the water connections It is imperative that heat is not applied to the...

Страница 7: ...the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valve Verify that the comb...

Страница 8: ...anufacturer listed on the rating plate or from your local plumbing supplier Please consult with a plumbing professional APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minu...

Страница 9: ...ater See figure 1A For bottom inlet models 503 models the cold water inlet is located on the side of the drain valve see figure 1B Connect the hot and cold water lines to the installed nipples using u...

Страница 10: ...ate amount of thread sealant to the provided nipples and install them into the side of the tank For 20 gallon utility models install the supplied anode nipple combination at the HOT outlet location Co...

Страница 11: ...are required to obtain a permit before starting the installation The water heater must be well grounded The green ground wire from the power supply shall be attached to the terminal marked for this pu...

Страница 12: ...12 Electrical Connections continued Figure 3A Figure 3B...

Страница 13: ...13 Electrical Connections continued Figure 4 Figure 4A...

Страница 14: ...41 0 11000 30 4 45 1 SINGLE PHASE FULL LOAD CURRENT DRAW NON SIMULTANEOUS OPERATION Element Wattage 120V 208V 240V 277V 380V 415V 480V 1500 1500 12 5 7 2 6 3 5 4 3 9 3 6 3 1 2000 2000 16 7 9 6 8 3 7...

Страница 15: ...4 8 4 2 2500 2500 12 0 10 4 6 6 6 0 5 2 3000 3000 14 4 12 5 7 9 7 2 6 3 3500 3500 16 8 14 6 9 2 8 4 7 3 4000 4000 19 2 16 7 10 5 9 6 8 3 4500 4500 21 6 18 8 11 8 10 8 9 4 5000 5000 24 0 20 8 13 2 12 0...

Страница 16: ...e water heater make sure you follow the steps below 1 Disconnect the power supply to the water heater Consult the plumbing professional or electric company in your area for service 2 Close the cold wa...

Страница 17: ...nd that the plastic terminal shield has not been displaced replace the access panel The water heater is now ready for operation and the main switch can be closed Figure 5 CAUTION Before adjusting ther...

Страница 18: ...the water heater Regular inspection and maintenance of the water heater will help to insure safe and reliable operation 1 Annually check the operation of the thermostat s 2 Bi annually check the seal...

Страница 19: ...hen necessary to prolong tank life Water conditions in your area will influence the time interval for inspection and replacement of the anode rod Contact the plumbing professional who installed the wa...

Страница 20: ...o Serial No Service Phone Days Nights Address Supplier Supplier Phone No Manufactured under one or more of the following U S Patents 5 277 171 5 341 770 5 372 185 5 485 879 5 574 822 5 596 952 5 660 1...

Отзывы: