GAS CONNECTIONS

 

 

The gas supply lines must meet all requirements of the 

National Fuel Gas 

Code, ANSI Z223.1

 - (Latest Edition) and/or in Canada, 

CAN/CGA B149 

Installation Codes

 - (Latest Editions). 

 
The minimum permissible gas supply pressure for the purpose of input 
adjustment is one (1.0) inch 

(.25kPa) 

water column above the operating 

manifold pressure.  See the rating plate and combination gas control for the 
manifold pressure and gas type.  The maximum permissible gas supply 
pressure is fourteen (14.0) inches 

(3.5kPa)

 water column for natural gas and 

liquefied petroleum gases/propane gas. 
 
1.   Connect this water heater only to the type of gas (natural or propane 
 

gas) as shown on the rating plate.  Use clean 1/2 inch black iron 

 

pipe.  (Dirt and scale from the pipe can enter the combination control and 
cause it to malfunction).  The inlet gas line must have a drip leg (

sediment 

trap) 

installed as close as possible to the water heater’s combination gas 

control having a minimum length of three (3) inches 

(7.6 cm).  

A ground 

joint union must be installed in the gas supply line feeding the water heater 
to permit servicing of the water heater. Compounds used on the threaded 
joints of the gas piping must be resistant to the action of liquefied 
petroleum gases/propane gas. 

 
2.   This water heater and its gas connection must be leak tested before  
 

placing the water heater in operation.  Check for gas leaks with a   

 

soap and water solution and a brush or a commercial leak detector  

 

fluid.

  NEVER USE A MATCH OR OPEN FLAME FOR TESTING! 

 

CAUTION 

The water heater and its individual shutoff valve must be disconnected from 
the gas supply piping system during any pressure testing of the system at 
test pressures in excess of 1/2 psi (3.5 kPa).  The water heater must be 
isolated from the gas supply piping system by closing its manual shutoff 
valve during any pressure testing of the gas supply system at test 
pressures equal to or less than 1/2 psi (3.5 kPa).  The supply line must be 
capped when not connected to the water heater. 

 

 
 
 

 
 
 

INTERNET VERSION FOR REFERENCE ONLY

Содержание DS140S

Страница 1: ...If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier For your family s comfort safety...

Страница 2: ...y read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning your warranty please consult the plumbing professional from whom...

Страница 3: ...ngths 14 Vent Air Intake System Installation 17 Water Connections 25 Gas Connections 29 GENERAL OPERATION 30 Lighting and Shutdown Instructions 31 Thermostat Adjustment 32 Burner Flame Checks 33 MAINT...

Страница 4: ...r installation in a mobile home Such an installation may create a hazardous condition and will nullify the warranty This water heater has been designed and certified for the purpose of heating potable...

Страница 5: ...onds with the marking on the rating plate and combination gas control A sacrificial anode is used to extend tank life The removal of this anode for any reason will nullify the warranty In areas where...

Страница 6: ...ed not less than 18 inches 46 cm above the floor and shall be located or protected to avoid physical damage For other installations refer to local codes In the absence of local codes the water heater...

Страница 7: ...IF EXPOSURE HAS OR WILL OCCUR DO NOT STORE ANY POTENTIALLY CORROSIVE COMPOUNDS IN THE VICINITY OF THE WATER HEATER WARNING Liquefied petroleum gases propane gas are heavier than air and will remain at...

Страница 8: ...d the venting section in this installation instruction manual before locating the water heater This water heater must be located in an area where leakage of the tank or water line connections and the...

Страница 9: ...mbustibles for this water heater is zero 0 inch 0 cm from the sides and rear four 4 inches 10 2 cm from the front of the jacket zero 0 inch 0 cm from the plenum zero 0 inch 0 cm from the air intake el...

Страница 10: ...10 Installation Minimum Clearances continued Figure 1 I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 11: ...11 Installation continued Figure 2 Figure 3 I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 12: ...equipment Must be installed in a location where it will not be blocked by snow Note Provide protection of the building materials from degradation by flue gases from the direct vent air intake termina...

Страница 13: ...porch or deck is fully open on a minimum of two sides beneath the floor and ii the distance between the top of the vent air intake termination and the underside of the verandah porch or deck is great...

Страница 14: ...per clearances for installation plumbing operation and service HORIZONTAL AND VERTICAL VENT AIR INTAKE LENGTHS This Direct Vent Gas Water Heater comes with one 1 vent air intake Kit C Optional vent ai...

Страница 15: ...C order kit D 14 3 4 15 11 16 order kit A 2 order kit A B order kit A order kit A C order kit A D 16 1 2 19 3 16 order kit A B order kit B 2 order kit B order kit B C order kit B D 23 3 4 33 11 16 or...

Страница 16: ...16 Installation Horizontal and Vertical Vent Air Intake Lengths continued Figure 6 I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 17: ...k Wall Construction Reciprocating Saw w appropriate Blade s Dependent on Wall Construction Chisel For Poured Concrete Concrete Block and Brick Wall Construction Hammer For Poured Concrete Concrete Blo...

Страница 18: ...the outside wall and connect with the direct vent air intake terminal See Figure 6 4 From outside the building position the outer wall mount plate and direct vent air intake terminal over the center o...

Страница 19: ...ace the straight end of the five 5 inch 12 7 cm diameter elbow over the three 3 inch 7 6 cm diameter elbow and plenum collar until seated on top of the plenum box Make certain that the five 5 inch 12...

Страница 20: ...ch diameter holes 120o apart through the three 3 inch 7 6 cm diameter elbow into the three 3 inch 7 6 cm diameter telescopic tube Fasten with three 3 8 sheet metal screws supplied Adjust the overall l...

Страница 21: ...ver the collar on the outer wall mount plate Drill three 3 1 8 inch diameter holes 120o apart through the five 5 inch 12 7 cm diameter telescopic tube into the collar on the outer wall mount plate Fas...

Страница 22: ...intake terminal into the three 3 inch 7 6 cm diameter telescopic tube that extends through the wall and position it so it is flush with the outer wall mount plate Make sure that the rain guard and th...

Страница 23: ...of the five 5 inch 12 7 cm diameter elbow one 1 inch 2 5 cm or until seated Drill three 3 1 8 inch diameter holes 120o apart through the five 5 inch 12 7 cm diameter elbow into the five 5 inch 12 7 cm...

Страница 24: ...the supplied wall anchors Install the wall anchors and secure the backing plate to the wall with four 4 10 x 1 inch screws supplied See Figure 15 Note Certain construction of walls may require the use...

Страница 25: ...n the top of the water heater The fittings at the cold water inlet and hot water outlet are dielectric waterway fittings with 3 4 NPT male thread Make the proper plumbing connections between the water...

Страница 26: ...e Verify that the combination temperature and pressure relief valve complies with local codes If the combination temperature and pressure relief valve does not comply with local codes replace it with...

Страница 27: ...NG Hydrogen gas can be produced in an operating water heater that has not had water drawn from the tank for a long period of time generally two weeks or more Hydrogen gas is extremely flammable To pre...

Страница 28: ...d and hot water in branch supply lines Such valves are available from the manufacturer of this water heater or a local plumbing supplier Please consult with a plumbing professional I N T E R N E T V E...

Страница 29: ...tion gas control having a minimum length of three 3 inches 7 6 cm A ground joint union must be installed in the gas supply line feeding the water heater to permit servicing of the water heater Compoun...

Страница 30: ...ady stream of water flows from the faucets the water heater is filled Close the faucets and check for water leaks at the water heater drain valve combination temperature and pressure relief valve and...

Страница 31: ...31 I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 32: ...within five 5 seconds at a temperature setting of 135 F 57 C To protect against hot water injury install an ASSE approved mixing valve in the water system This valve will reduce point of discharge te...

Страница 33: ...tervals not more than six 6 months a visual check of the pilot and main burner flames should be conducted The flames should be similar to those pictured below The main burner should light smoothly fro...

Страница 34: ...ns the maintenance interval may be more frequent depending on upon the amount of use and the operating conditions of the water heater Regular inspection and maintenance of the water heater and vent ai...

Страница 35: ...released water does not result in bodily injury or property damage 8 Monthly drain off a gallon of water to remove silt and sediment by using the water heater s drain valve 9 If the combination temper...

Страница 36: ...tured under one or more of the following U S Patents 4 416 222 4 628 184 4 669 448 4 672 919 4 808 356 4 829 983 4 861 968 4 867 106 4 904 428 5 000 893 5 023 031 5 052 346 5 081 696 5 092 519 5 115 7...

Страница 37: ...ron Burner Certain Models 13 Glass Lined Tank 32 Radiation Shield 14 Flue Baffle Assembly 33A Direct Vent Air Intake Kit A Optional 15 Dip Tube Nipple 33B Direct Vent Air Intake Kit B Optional 16 Anod...

Страница 38: ...38 DIRECT VENT WATER HEATER I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 39: ...39 VENT AIR INTAKE KITS I N T E R N E T V E R S I O N F O R R E F E R E N C E O N L Y...

Страница 40: ...t not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with a non potable water heating ap...

Отзывы: