background image

Page 3

 

WARNING

 

Should overheating occur or the gas supply fails to 

shut off, do not turn off or disconnect the electrical 

supply to the pump. Instead, shut off the gas supply 

at a location external to the appliance.

 

WARNING

 

Do not use this boiler if any part has been under 

water. Immediately call a qualified service technician 

to inspect the boiler and to replace any part of the 

control system and any gas control which has been 

under water.

1.C 

System Shutdown

1.  Turn OFF the main power switch.

 

2.  Close the manual gas valves

 

.

3.   If you think the unit might freeze, drain it.  All water 

must be removed from the heat exchanger, or 

damage from freezing may occur. To completely 

drain the boiler, first drain the right side by opening 

the boiler drain. Then remove the PRV and related 

fittings. Then remove the top and left side panels. 

Remove BOTH 1/2” plugs from the side of the boiler 

located at the bottom of the casting. Once the water 

is fully drained, reinstall the plugs and panels. Refer 

to the Installation and Operating Manual. 

4.   Also be sure to protect the piping in the building 

from freezing.

 

1.D   Blocked Vent Safety Shut Off

     This boiler is equipped with a blocked vent safety 

shut off system (BVSSS) to shut off the boiler if 

the vent is obstructed for any reason. Operation 

with an obstructed vent will cause the combustion 

system to create Carbon Monoxide (CO). Do not 

attempt to restart the boiler if it has been shut off by 

the BVSSS. Turn the power off and call a qualified 

Service Technician. 

1.F 

Maintenance

1.   Lubricate any motor bearings that are not sealed 

bearings per the instructions.

 

2.   If a strainer is employed in a pressure reducing 

valve or the piping, clean it every six months or as 

needed.

 

3.   At start-up, and periodically thereafter, the burner 

and pilot flames should be observed. If the flame 

has the appearance of “sooting” tips, check for 

debris near the orifices. Clean any debris from 

orifice area and remove burners to ensure they are 

debris free inside and out. If this doesn’t clear the 

issue the heat exchanger likely needs cleaning.

 

4.   Ensure Vent Damper motors open and close by 

watching the connecting rod between the stack and 

the motor housing. The boiler should never start if 

the damper is not in the open position.  If it does, it 

is critical to safe operation that this gets repaired.

1.E   Flame Roll-out Safety Shut Off

     This boiler is equipped with a flame roll-out safety 

shut off system. The flame roll-out safety shut off is 

located inside the front cover and and just above 

the burners. The flame roll-out safety switch should 

only be replaced by a qualified Service Technician. 

If the boiler shuts off or will not start up due to the 

flame roll-out safety switch, then turn the power off 

and call a qualified Service Technician. .

 

 

WARNING

The Warranty does not cover damage caused by 

lack of required maintenance, lack of water flow, 

or improper operating practices.

 

 

AVERTISSEMENT

 

La garantie ne couvre pas les dommages causés 

par l'absence d'entretien, absence de débit d'eau, 

ou pratiques de fonctionnement irrégulières

8.    Allow the boiler to operate until the target 

temperature or high temperature set point is 

reached. The yellow “target” LED or the yellow 

“hi-temp” LED will light. The main burner and pilot 

flame will turn off. The “flame” LED will turn off.

9.   The damper will begin to close and the “v-pwr’’, “v-

sw”, and “limits” LEDs will turn off. 

10.    Lower the room thermostat temperature to remove 

the call for heat. The third decimal, lower right of 

the control display will turn off 

 

WARNING

Installation, maintenance, and service must be 

performed by a qualified installer, service agency, or 

gas supplier.

 

 

AVERTISSEMENT

 

L’installation, etretian, et l’entretien doivent être 

assurés par un installateur ou un service d’entretien 

qualifié ou par le fournisseur de gaz.

RESIDENTIAL BOILERS

Brute-Mini

®