6
SECTION II: SPECIFICATIONS
Table 1.
Specifications
.
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** For commercial and hydronic applications requiring higher temperatures. Requires the use of an optional controller
(P/N 239-47805-00).
Bradford White Corporation is continually updating and improving products. Therefore, specifications are subject to
change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.
Model
TG-150I-N(X) TG-180I-N(X) TG-199I-N(X) TG-237I-N(X) TG-237I-N(X)A
Minimum Rate Btu/h
15,000
19,000
Maximum Rate Btu/h
150,000
180,000
199,000 Natural
Gas
190,000
Propane
237,000
Flow Rate (Min-Max) *
0.6-5.0 GPM
(2.3-18.9
L/min)
0.6-7.5 GPM
(2.3-28.4 L/min)
0.6-9.4 GPM
(2.3-35.5 L/min)
0.6-9.8 GPM
(2.3-37 L/min)
Flow Rate (45F rise)
5.0 GPM
(18.9 L/min)
6.7 GPM
(25.4 L/min)
7.1 GPM
(27.0 L/min)
8.5 GPM
(32.2 L/min)
Default Temperature Setting
104°F (40°C)
Maximum Temp Setting (commercial **)
160°F (71°C)
180°F (82°C)
185°F (85°C)
Maximum Temp Setting (residential)
120°F (49°C)
Minimum Temperature Setting
96°F (36°C)
98°F (37°C)
Weight
50 lb (23 kg)
55 lb (25 kg)
Energy Factor
0.82
0.82
0.82
N/A
Thermal Efficiency
84%
Noise level (inside rating)
49 dB
Electrical
Consumption
Normal
53 W
65 W
79 W
99 W
Standby 2
W
Anti-frost
Protection
100 W
100 W
116 W
By-Pass Control
Fixed
Electronic
Minimum Gas Supply
Pressure
Natural Gas
5.0 inch W.C.
Propane
8.0 inch W.C.
Maximum Gas Supply
Pressure
Natural Gas
10.5 inch W.C.
Propane
13.5 inch W.C.
Type of Appliance
Direct Vent, Temperature controlled continuous flow gas water heater
Operation
With or without remote controls, mounted in kitchen, bathroom, etc.
Approved Gas Type
Natural Gas or Propane-Ensure unit matches gas type supplied at the installation location.
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System
Direct Spark Ignition
Electric Connections
Water Heater: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback
Minimum Water Supply Pressure
20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Remote Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
ENERGY STAR
®
Qualified
Yes (Both U.S. and Canada)
No
Содержание BRADFORD WHITE EVERHOT TG-150I-N(X)
Страница 16: ...16 Figure 4 Recommended Piping for a Basic Installation...
Страница 17: ...17 Figure 5 Recommended Piping for a Circulation Systems...
Страница 51: ...51 Figure 42 Wiring Diagram for TG 150I N X TG 180I N X and TG 199I N X Models...
Страница 52: ...52 Figure 43 Wiring Diagram for TG 237I N X and TG 237I N X A Models...
Страница 72: ...72 SECTION X PARTS LIST TG 150I TG 180I and TG 199I Models...
Страница 74: ...74...
Страница 76: ...76...
Страница 78: ...78...
Страница 80: ...80 TG 237I Models...
Страница 82: ...82...
Страница 84: ...84...
Страница 86: ...86...
Страница 91: ...91 NOTES...