Commercial Atmospheric Vent Gas Water Heater
NATURAL GAS AND LIQUID PROPANE GAS
Light Duty Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
79% Thermal Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
G
Floor to
Space
Htg.
Outlet
in.
A
Floor to
Flue
Conn.
in.
H
Floor to
Water
Conn.
in.
B
Jacket
Dia.
in.
Capacity
Recovery at
100°F Rise*
50T-65FB-3N
65T-65FB-3N
U.S.
Gal.
Imp.
Gal.
Nat.
BTU/Hr.
Input
65,000
65,000
Nat.
U.S.
GPH
Nat.
Imp.
GPH
59
1
/
4
63
57
60
3
/
4
164
205
22
24
50
53
1
/
2
E
Floor to
Gas
Conn.
in.
13
12
3
/
16
13
1
/
2
13
1
/
2
F
Floor to
Space
Htg.
Return
in.
63
63
53
53
LP
U.S.
GPH
LP
Imp.
GPH
59
61
49
51
48
65
40
54
D
Floor to
T&P
Conn.
in.
50
53
1
/
2
C
Vent
Size
in.
4
4
Model
Number
Approx.
Shipping
Weight
kg.
G
Floor to
Space
Htg.
Outlet
mm.
A
Floor to
Flue
Conn.
mm.
H
Floor to
Water
Conn.
mm.
B
Jacket
Dia.
mm.
Capacity
Recovery at
56°C Rise*
50T-65FB-3N
65T-65FB-3N
Liters
Nat.
kW
Input
19.1
19.1
LP
BTU/Hr.
Input
61,000
63,000
LP
kW
Input
17.9
18.4
182
246
Nat.
Liters/
Hour
1550
1600
1448
1543
K
Depth
in.
26
28
K
Depth
mm.
660
711
74
93
559
609
1270
1359
E
Floor to
Gas
Conn.
mm.
330
309
343
342
F
Floor to
Space
Htg.
Return
mm.
238
238
LP
Liters/
Hour
223
231
D
Floor to
T&P
Conn.
mm.
1270
1359
C
Vent
Size
mm.
102
102
K
K
E
C
B
A
H
H
D&G
F
B
**
E
F
A
TOP VIEW
T
C
A
D&G
** 75T=11"
** 100T=16"
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "B" to "S" and "N" to"X".
For 5 year models, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
NSF kits available.
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT
(19mm) on 8" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Printed in U.S.A.
700-B 0109
©2009, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
●
Fax 215-641-1670 / Technical Support 800-334-3393
●
Fax 269-795-1089
●
Warranty 800-531-2111
●
Fax 269-795-1089
International:
Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www.bradfordwhite.com