Pre-installation continued-
Clearance from Combustible Materials
Top Sides Front Rear
0” 0” 0” 0”
Table 6 – Combustible Material Clearances
Recommended Service Clearances
Non-Piping
Side
Front
(Thermostat)
Rear
T & P Relief
Valve Side
4” 16”
0”
4”
Table 7 – Service Clearances
Appliance Location
1.
Boiler Location –
Locate the indirect-fired water heater as
close to the boiler as practical.
2.
Fixture Locations –
For fastest delivery of hot water, place
the indirect-fired water heater close to points of use.
Additional Recommended Components
1.
Shut-off Valves –
Allows isolation of water heater from
domestic water system and/or boiler system during service.
2.
Unions –
Allows water heater movement during service if
adequate clearance cannot be provided.
3.
Thermal Expansion Tank –
If the water heater is installed in
a closed water supply system, such as one having a back-flow
preventer in the cold water line, provide thermal expansion
control. Contact the water supplier or local plumbing inspector
for additional information.
CAUTION
Do not drop water heater. Do not bump water heater jacket against
floor.
WARNING
Do not plug the inlet and outlet tappings of tankless heater left
installed in the boiler.