10

VENTING

 

 

 

 
This water heater has been shipped with a draft diverter for which it was 
designed with reference to the horizontal and vertical planes.  If removed, the 
draft diverter must be replaced in the same position and secured to the jacket 
top by the screws with which it was installed. 

 

WARNING 

The venting system must be installed properly following all local codes or in 
the absence of local codes, the latest edition of the National Fuel Gas Code 
(ANSI Z223.1- latest edition), or in Canada, The Natural Gas and Propane 
Installation Code (B149.1-00 latest edition).  Failure to properly install the 
venting system could result in property damage, personal injury, or death.

 

WARNING 

Carefully inspect the venting system of a replacement water heater 
installation before connecting to the venting system.  All joints in the vent 
connector must be securely fastened with screws and fit tightly together.  
Inspect the venting system for signs of deterioration (rust and perforation) 
and replace any sections that are not in good condition. 
The chimney must be lined and in good condition.  Check to make sure the 
venting system is properly sized for the water heater.  If the venting system 
was previously sized for another gas appliance that has been removed, the 
venting system may now be too large.  Refer to the latest edition of the 
National Fuel Gas Code (ANSI Z223.1-latest edition), or in Canada, the 
Natural Gas and Propane Installation Code (B149.1-00 latest edition) for the 
correct sizing of venting systems and common venting with another gas 
appliance. 
Do not vent this water heater into the venting system of another gas 
appliance designed to vent under positive pressure. 
The water heater should be installed as close as practical to the venting 
system to minimize the vent connector length required.  Refer to local codes 
for the distance limitations on vent connector lengths. 
At the completion of the water heater installation, the burner and venting 
system must be checked for proper operation with all other commonly 
vented appliances in operation.  Check for spillage of flue products around 
the outside relief opening of the drafthood after several minutes of 
operation.  The flame from a match should be drawn into the drafthood.  Do 
not use the water heater or connected equipment if spillage is detected until 
the problem is corrected.  Refer to the latest edition of the National Fuel Gas 
Code, or in Canada, the Natural Gas and Propane Installation Code for 
complete details on the “Procedure to Be Followed to Place Equipment in 
Operation”.  

 

Содержание 238-44219-00J

Страница 1: ...each your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier For your family s comfort safety and convenience...

Страница 2: ...vent of improper usage or storage of gasoline or other flammable materials in the location where the water heater is installed the technology will resist ignition of the flammable vapors outside the c...

Страница 3: ...pply 11 Water Connections 13 Gas Connections 16 GENERAL OPERATION 17 Lighting and Shutdown Instructions 18 Thermostat Adjustment 20 Burner Flame Check 22 MAINTENANCE 23 TROUBLESHOOTING 26 INSTALLATION...

Страница 4: ...e to comply with these instructions This water heater is not design certified for installation in a mobile home Such an installation may create a hazardous condition and will nullify the warranty This...

Страница 5: ...on gas control A sacrificial anode is used to extend tank life The removal of this anode for any reason will nullify the warranty In areas where water is unusually active an odor may occur at the hot...

Страница 6: ...ible to gas and water supply lines DO NOT locate the water heater where water lines could be subjected to freezing temperatures Make sure the cold water pipes are not located directly above the gas co...

Страница 7: ...little or no odor to reveal their presence NOTE DAMAGE TO THE WATER HEATER CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE WARRANTY DO NOT OPERATE THE WATER HEATER IF EXPOSURE HAS OR WIL...

Страница 8: ...e purchased from your plumbing professional The drain pan must be piped to an adequate drain The piping must be at least 3 4 inch 1 9 cm in diameter and pitched for proper drainage It is recommended t...

Страница 9: ...it shall be installed on top of a metal or wood panel or equivalent extending beyond the full width and depth of the appliance by at least three 3 inches 7 6 cm in any direction or if the appliance is...

Страница 10: ...system was previously sized for another gas appliance that has been removed the venting system may now be too large Refer to the latest edition of the National Fuel Gas Code ANSI Z223 1 latest editio...

Страница 11: ...ers and flue tubes with possible damage to the water heater When an exhaust fan is installed in the same room with a heater sufficient openings for air must be provided in the walls Undersized opening...

Страница 12: ...ottom of the enclosure All Air From Outdoors The confined space shall be provided with two permanent openings one commencing within 12 inches 31cm of the top and one commencing within 12 inches 31cm f...

Страница 13: ...sion DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control this...

Страница 14: ...pressure relief valve into the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief...

Страница 15: ...pplier Please consult with a plumbing professional APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C...

Страница 16: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 17: ...F position 3 Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockwise The drain valve h...

Страница 18: ...18 Lighting and Shutdown Instructions White Rodgers and Robertshaw gas control...

Страница 19: ...19 Lighting and Shutdown Instructions Honeywell gas control...

Страница 20: ...e dial until the minimum acceptable temperature is achieved See figure 2 above for approximate temperature settings Robertshaw gas control 160 F Control 180 F Control Figure 3 The thermostat dial is s...

Страница 21: ...setting Adjust the dial until the minimum acceptable temperature is achieved See figure 4 above for approximate temperature settings Figure 5 The thermostat dial is set to its lowest temperature sett...

Страница 22: ...fail to shut off turn off the manual gas control valve to the appliance and call a qualified service technician Note Whenever the water heater is filled with cold water condensate will form on the coo...

Страница 23: ...s listed on the water heater 5 Annually remove the inner door and main burner assembly to clean orifices and related parts of any dirt or other foreign material Inspect the burner ports for obstructio...

Страница 24: ...al for inspection and replacement of the anode rod Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating plate for anode replacement information The...

Страница 25: ..._ Supplier Supplier Phone No ____________________________________________ CAUTION FOR YOUR SAFETY DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL BURNERS OR GAS PIPING REFER REPAIRS TO A QUALIFIED SE...

Страница 26: ...o OFF position Wait until LED goes out before attempting to relight Two flashes and three second pause Weak pilot flame detected System will reset when pilot flame is sufficient 1 Unstable pilot 2 Pil...

Страница 27: ...electronic fault detected 1 Verify control is not wet or physically damaged 2 Turn set point knob to OFF position Turn set point knob to PILOT position and light pilot 3 Replace gas valve if seven fla...

Страница 28: ...28 INSTALLATION FOR POTABLE WATER Figure 7...

Страница 29: ...29 PARTS LIST DRAWING...

Страница 30: ...ot Water Outlet 18 Orifice 6 Flue Baffle Assembly 19 Gas Feedline to Burner 7 Dip Tube Cold Water Inlet 20 Gas Feedline to Pilot 8 Temperature and Pressure Relief Valve 21 Thermocouple Lead 9 Glass Li...

Страница 31: ...or boiler treatment must not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with a non p...

Страница 32: ...32 NOTES...

Отзывы: