Brada Appliances YPM-06C Скачать руководство пользователя страница 10

 

 - 

10- 

 
 
 
 

1. Simple steps to use cooling mode 

Plug in the power cord and press the “POWER” button 
Press “MODE” to chose COOLING mode.                             
Press “UP” or “DOWN“ to set the desired temperature. The temperature ranges from 59F to 
86F(15C~30C) 
Press, “SPEED” to set a desired fan speed.   
The fan will run first. After few minutes, the compressor will start to run if the room temperature is higher 
then the setting temperature. The compressor will stop running when the room temperature is below the 
setting temperature.   

 

2. Setting the timer 

(1)  Turn off the unit automatically:   

When the unit is running, press TIMER to set operating duration, and then the LED will flash five times. 
During this period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After 
setting, the LED will flash five times and then display the room temperature again. When the operating 
duration reaches the pre-set time, the power will turn off automatically. 

 

(2)  Turn on the unit automatically:   

When the unit is off, press TIMER to set start time, and then the LED will flash five times. During this 
period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After setting, the 
LED will flash five times and then display the temperature again. Once the pre-set time is reached, the 
power will turn on automatically.

   

(3)  Change the setting: 

When TIMER is on, you can check the remaining time by pressing the TIMER button. It will flash five 
times. Press Up or Down button to adjust the timer. The timer can be canceled if you press the TIMER 
button once again when LED is flashing.   

 

Attention: 

If the unit is suddenly turned off during operation, the compressor will start to run three minutes after 
the power is turned back on. 

 

3. Setting operating mode

 

ƒ

 

COOLING:

 When this mode is selected, the fan will run first and then the compressor will start to run 

five minutes after the power is on. To set your desired temperature, press UP or DOWN button. The 
temperature ranges from 15C~30C (59F~86F). When the room temperature is lower than the setting 
temperature, the compressor will stop running until the room temperature is higher than setting 
temperature. In this case, only the fan will keep running.   

 

ƒ

 

FAN:

 When this mode is selected, the temperature setting cannot be changed, but you can set your 

desired speed. There is no need to use the air exhaust duct in this mode. 

 

ƒ

 

DEHUMIDIFING:

 When this mode is selected, it presets the fan speed and mode, and these settings 

cannot be changed. Under this mode, the compressor will not run, and LED will display room 
temperature. There is no need to use the air exhaust duct. You may need to drain water with the drain 
pipe if the humidity is very high.   

 

4 .Setting temperature 

In COOLING mode, press the “UP” button to increase the temperature setting or press the “DOWN 
“ button to lower the temperature setting. When the number is flashing, it indicates the temperature you 
are setting up. When the number is lit but not flashing, it indicates the current room temperature.   

 

5. Setting fan speed 

In COOLING and FAN mode, press “SPEED” to adjust the fan speed. There are high, medium and low 
modes. Each fan speed corresponds to one indicator on LED control panel. Please note: when unit is in 
dehumidifier mode, the fan speed cannot be adjusted. 
 
 
 

OPERATING INSTRUCTION

Содержание YPM-06C

Страница 1: ... OR RT TA AB BL LE E A AI IR R C CO ON ND DI IT TI IO ON NE ER R Instruction Manual Please read the instructions completely before using this product This product is designed for household use only YPM 06C ...

Страница 2: ... is on keep doors and windows closed Turn off kitchen or bathroom exhaust fans when your air conditioner is on Operate the unit in recommended room size 107 sq ft 15 sq m for 5 000 BTU Turn off the air conditioner when you leave home Check the filter monthly and keep it clearn Do not place anything that may gnereate heat near the thermostat or the air conditioner may run longer then necessary Keep...

Страница 3: ...not use the product near a bath shower or swimming pool or in any other steamy or wet areas 13 Do not turn off on the product by plugging or unplugging the power cord directly 14 Do not modify the power cord or share the outlet with other appliances 15 Unplug the product from the outlet when not in use and before cleaning 16 Attachments not recommended by the manufacturer as they may cause injurie...

Страница 4: ... working properly please follow the following instructions to test it 1 Plug power cord into wall outlet 2 Press TEST button The circuit should trip cutting power to the air conditioner 3 Press RESET button for use DO NOT USE IF ABOVE TEST FAILS In the event the LCDI Plug of the power cord trips by itself then first examine the cord for any damage If there is no damage to the cord then press the R...

Страница 5: ...n and dehumidifying function 2 Colorful LED display with remote control 3 Quiet and easy operation 4 Auto defrosting function 5 24 hour timer on off function 6 Auto swing function of horizontal 7 Three minutes restart delay to protect compressor PARTS NAMES ...

Страница 6: ...ist them 3 Connection of hot air exhaust hose 1 Assemble the hot air exhaust hose connector as follows Do not use excessive force as adaptor may be damaged 2 Extend the exhaust pipe put one side of it into the hot air exhaust outlet Turn it counter clock wise at least 5 turns and then put the other side into the hose connector and turn it clock wise 3 Put the sliding bar on the window It s designe...

Страница 7: ...pects of the installation procedures for certain types of windows Notes The length of hot air exhaust hose is between 11 to 59 The length of the hot air exhaust hose is designed especially according to the specifications of the air conditioner do not use an extension or a longer replacement hose as that may cause a malfunction Do not bend or twist the hot air exhaust hose more than 45 angle ...

Страница 8: ...DE Press this button to select cool fans or dehumidify function p SWING Press this button to make the horizontal louver swing To stop swing press this bottom again q FAN Fan speed setting r TIMER Press this button to enter time setting status st UP DOWN Press up or down button to set temperature or adjust the timer in timer setting press both buttons to convert from Celsius to Fahrenheit OPERATING...

Страница 9: ... button to select Auto Cooling Fan or Dehumidifying mode FAN Press this button to select High or Low fan speed SWING Press this button to turn on off the auto swing function TIMER Press this button to set up time ECON Press this button to force the unit into a strong cooling mode without any limitation of room temperature in cooling mode SLEEP Press this button to active or cancel sleep function i...

Страница 10: ... once again when LED is flashing Attention If the unit is suddenly turned off during operation the compressor will start to run three minutes after the power is turned back on 3 Setting operating mode COOLING When this mode is selected the fan will run first and then the compressor will start to run five minutes after the power is on To set your desired temperature press UP or DOWN button The temp...

Страница 11: ...be displayed The unit will restart automatically after the frost has been dissipated Suggestion Do not have the air conditioner running in the cooling or dehumidify mode when the room temperature is below 15 59F 8 Sleep Function To active or cancel the sleep function by remote control under cooling mode The unit will run at low fan speed as default with lower noise The setting temperature will inc...

Страница 12: ... the water and restart the air conditioner as follows 1 Unplug the unit 2 Put a vessel such as water tank under the drainage port 3 Remove the drainage cap and water stopper 4 Drain out the water fully 5 Insert the water stopper and screw down the drainage cap 6 Plug in and restart the air conditioner Drainage port Water stopper Drainage cap Cautions Move the air conditioner carefully when the wat...

Страница 13: ...the air filters by immersing them into warm below 40 or 104 water with neutral detergent and dry them at room temperature z Put the air filter back to its original position After season maintenance and storage z Remove the water stopper to empty the water in the air conditioner z Clean air filter z Have the air conditioner run in fan mode at low fan speed for 4hours to ensure the internal air cond...

Страница 14: ...e temperature of compressor is reduced Is the distance too far from the unit Is the signal not received by unit Use remote control near the unit and make sure it aims at the remote control receiver on the unit Remote control doesn t work Is the battery exhausted Change new battery NOTE Stop running the unit and pull out the plug if the problem is beyond the trouble shooting chart and call service ...