Brada Appliances YPL3-10C Скачать руководство пользователя страница 8

8

Incorrect mounting

The  bend  of  the  exhaust  pipe  is  very  important. 

Incorrect  mounting  can  prevent  the  machine  from 

working correctly.

Take  care  to  prevent  any  sharp  bows  or  bends  of  the 

exhaust pipe.

The exhaust air must flow freely

                                                                                                   

WARNING

The length of the exhaust pipe is specially designed according to the specification of this 

product.  Do  not  replace  or  prolong  it  with  your  own  private  hose  as  this  could  cause 

mal-function.

BE  CAREFUL:

 

Maximum  developed  length  of  the  exhaust  pipe  is  1500mm. Use  the 

shortest  possible  length.  When  mounting,  we  advise  to  keep  the  exhaust  pipe  in  a 

horizontal position.

PART NAME

Front                                                                                                                                                                                                         

1. Control panel

2. Display

3. Button                         

4. Remote control receiver

                   

5. Air outlet vent

6. Louver

7. Castor

8. Remote Control

8

9

4

5

6

3

2

1

7

Содержание YPL3-10C

Страница 1: ...Air Conditioner Instruction Manual YPL3 10C Please read the instructions completely before using this product This product is designed for household use only FOR SERVICE CALL TRANS GLOBAL SERVICE 1 800 360 2742 ...

Страница 2: ...2 CONTENT INTRODUCTION 2 SAFETY 5 INSTALLATION 6 PART NAME 7 CONTROL PANEL 9 REMOTE CONTROL 10 OPERATION METHODS 11 WATER DRAINAGE 12 MAINTENANCE 12 TROUBLESHOOTING 13 ...

Страница 3: ...f kitchen or bathroom exhaust fans when your air conditioner is on Operate the unit in recommended room size 300 sq ft 28sq m for 10 000 BTU Turn off the air conditioner when you leave home Check the filter monthly and keep it clearn Do not place anything that may generate heat near the thermostat or the air conditioner may run longer then necessary Keep blinds and curtains closed during hot weath...

Страница 4: ...age may occur 12 Do not use the product near a bath shower or swimming pool or in any wet enviorment 13 Do not turn off on the product by plugging or unplugging the power cord directly 14 Do not modify the power cord or share the outlet with other appliances 15 Unplug the product from the outlet when not in use and before cleaning 16 Do not use attachments not recommended by the manufacturer as th...

Страница 5: ...To ensure if the plug is working properly please follow the following instructions to test it 1 Plug power cord into wall outlet 2 Press TEST button The circuit should trip cutting power to the air conditioner 3 Press RESET button for use DO NOT USE IF ABOVE TEST FAILS In the event the LCDI Plug of the power cord trips by itself then first examine the cord for any damage If there is no damage to t...

Страница 6: ...a short time Never pull the cord to unplug or move the appliance Never immerse the appliance in water or any other liquid for any reason Keep the appliance away from water or oil splashes Respect the instructions for cleaning Do not insert sharp metallic objects or fingers in the air swinging fins of the appliance Never repair the appliance yourself All interventions made by a non qualified person...

Страница 7: ...lection of installation location Keep the unit on a flat surface and dry place Leave at least 50cm space all around the unit Installation Fix the exhaust pipe into the adapter and then fix the other side of the exhaust pipe into the air outlet vent of the unit anti clockwise Fix the adapter into the window slider kit and then half open the window to meet the width of the window slider kit The leng...

Страница 8: ...specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause mal function BE CAREFUL Maximum developed length of the exhaust pipe is 1500mm Use the shortest possible length When mounting we advise to keep the exhaust pipe in a horizontal position PART NAME Front 1 Control panel 2 Display 3 Button 4 Remote control rece...

Страница 9: ...ord 12 Big filter 13 Small filter 14 Draining hole Check all the accessories included in the package and please refer to the installation instructions for their usage Accessories Exhaust pipe Adapter Window slider kit A Window slider kit B 14 13 12 11 10 ...

Страница 10: ...ic time on when running time press this key to set automatic time off 5 UP button press this button to set the temperature higher when cooling press this button to adjust time longer when timing to exchange Fahrenheit and Celsius when press both UP and Down button 6 DOWN button press this button to set the temperature lower or higher when cooling press this button to adjust time shorter or longer ...

Страница 11: ...ius and Fahrenheit exchange button 3 Fan button 4 Cool Mode Button 5 Auto mode button 6 Down button 7 Up button 8 High fan speed button 9 Low fan speed button 10 Max cool button 11 Sleep Mode 12 Timer button 7 6 5 8 4 9 3 10 11 2 1 12 ...

Страница 12: ...ode You can select the fan speed mode and timer mode when it is under automatic adjusting mode Sleep Mode Optional Function Press this button to activate or cancel sleep function in cooling mode The unit will run at the low fan speed as default with lower noise The setting temperature will increase 1 degree per 2 hours running time and it will not change after increasing 2 degrees Max cool Mode Op...

Страница 13: ...INTENANCE Note Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock Cleaning Unplug the unit before any cleaning Clean the housing with a soft moisture cloth Do not use chemical solvent such as benzene alcohol gasoline The surface may be damaged or even the whole case may be deformed Do not sprinkle water on the unit Air filter Clean the air filter every ...

Страница 14: ...shes on the display screen Drain water Timer off is running You can turn on the unit three minutes later The air conditioner restart frequently In direct sunlight Close curtains Windows or doors open many people or a heat source in the room Close doors and windows remove the heat source Dirty filter Clean or replace the filter s Air inlet or air outlet blocked Remove the blockage The unit is too n...

Отзывы: