background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

YD30

  COBALT

 

      

 

INSTALLATION AND OPERATING INSTRUCTIONS 

       

 

 

      

 

Содержание YD30 Cobalt

Страница 1: ...YD30 COBALT INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...NT o 4 1 Mechanical o 4 2 Electrical 5 INSTALLATION o 5 1 Mortise Installation o 5 2 Surface installation 6 WIRING o 6 1 Fail Safe connection o 6 2 Fail Secure connection o 6 3 Jumper position 7 OPERATION o 7 1 Fail Safe Operation o 7 2 Fail Secure Operation 8 SPECIFICATIONS 9 MAINTENANCE 10 WARRANTY 11 UPGRADE Pg 2 Pg 2 Pg 3 3 3 3 3 3 Pg 4 4 4 Pg 4 4 6 Pg 8 8 8 9 Pg 9 9 9 Pg 10 Pg 10 Pg 10 Pg 10 ...

Страница 3: ...vates A door that is 8mm off alignment in either direction 16mm total window will be secured with the COBALT With the door secured and locked the COBALT can be given an unlock signal and it will instantly unlock If the door is loaded pre load when the unlock signal is given the COBALT will still unlock even with loads in excess of 100Kg on the door Critically the ability of the COBALT to instantly...

Страница 4: ... BQT Solutions SEA Pte Limited Page 3 3 DIMENSIONS 3 1 Lock 3 2 Strike Plate 3 3 Fitting Tab 3 4 Housing Available separately 3 5 Dress Plate Available separately ...

Страница 5: ...t position feedback These optional connections can be integrated into access control or alarm systems to provide full monitoring The correct gauge of wire needs to be chosen as voltage drop across the power wires and can limit the locks operation For all the remaining connections a lower gauge wire can be used as these are only signal wires The following chart shows the maximum distance that the p...

Страница 6: ...e made to the supplied wire loom which in turn plugs into the lock The jumper needs to be positioned for fail safe fail secure configuration as per the instructions on the lock cover The Red Black and Blue wires are essential connections whilst the Violet and White are optional Detailed wiring instructions can be found in Section 6 5 1 3 Fitting the lock and strike plate The lock is slid back into...

Страница 7: ...ing determine exactly where the wiring will enter the housing and drill one or two 8mm holes through the housing wall Ensure the holes are on the housing face that goes against the wooden frame Push the supplied grommet s into the drilled hole s The two 10G Hex head self tapping screws supplied with the housing can then be screwed into the wood but not tightened The two keyhole shaped cut outs in ...

Страница 8: ...glass to give a clean finish The protective coating on the dress plate can be removed once it is in place 5 2 5 Fitting the strike plate into the housing The strike plate is placed into the housing and secured in place with the supplied M5 machine screws 5 2 6 Checking the operation With the lock and strike installed and wiring complete the door is closed to check the alignment and operation The k...

Страница 9: ...s open Door Position Switch WHITE COM 6 1 Fail Safe Connection When wiring the COBALT the positive voltage is connected to RED negative is connected to BLACK and a switched positive voltage wire connected to BLUE In Fail Safe configuration applying voltage to the COBALT signals it to lock The lock signal in Fail Safe configuration is active high 6 2 Fail Secure Connection When wiring the COBALT th...

Страница 10: ...ong as the door is open but will instantly re lock when voltage is applied to the BLUE wire and the door is closed In the event of a power failure voltage is removed from the BLUE wire and the COBALT unlocks 7 2 Fail Secure Operation Assume the lock is installed and wired the door is open and voltage is removed from the BLUE wire As the door closes the COBALT senses the door approaching and activa...

Страница 11: ...rating Current after initial power up is 250mA 12VDC and 200mA 24VDC 9 MAINTENANCE The COBALT has been lubricated at assembly and applying any other type of lubricant may void the warranty Removing the lock cover may void the warranty A dry cloth can be used to polish the stainless steel face plate and strike plate as required 10 WARRANTY The COBALT is covered with a manufacturers 12month warranty...

Страница 12: ... BQT Solutions SEA Pte Limited Page 11 NOTES Version 3 0 ...

Отзывы: